Masonry walls are not isotropic; they have less strength in bending in the vertical direction than in the horizontal. The design of two-way spanning masonry panels under lateral loads is therefore complicated and tedious.
The design tables in this book present a straightforward and practical approach to the design of rectangular lateral loaded panels under uniformly distributed loads. The tables give the ultimate load capacity of masonry panels of different sizes, properties and edge conditions. They cover both unreinforced and bed joint reinforced masonry panels. The basis of the preparation of the design tables is that presented in BS 5628 Part 1: 1992 and Part 2: 1995.
The load tables will improve the efficiency of the design process and be a considerable asset to the practising engineer.
Le informazioni nella sezione "Riassunto" possono far riferimento a edizioni diverse di questo titolo.
EUR 2,26 per la spedizione in U.S.A.
Destinazione, tempi e costiEUR 3,41 per la spedizione in U.S.A.
Destinazione, tempi e costiDa: Books Puddle, New York, NY, U.S.A.
Condizione: New. pp. 56. Codice articolo 26457315
Quantità: 1 disponibili
Da: Majestic Books, Hounslow, Regno Unito
Condizione: New. pp. 56. Codice articolo 7423420
Quantità: 1 disponibili
Da: Biblios, Frankfurt am main, HESSE, Germania
Condizione: New. pp. 56. Codice articolo 18457321
Quantità: 1 disponibili
Da: GreatBookPrices, Columbia, MD, U.S.A.
Condizione: As New. Unread book in perfect condition. Codice articolo 38646716
Quantità: 1 disponibili
Da: PBShop.store UK, Fairford, GLOS, Regno Unito
PAP. Condizione: New. New Book. Shipped from UK. Established seller since 2000. Codice articolo FW-9780727725264
Quantità: 1 disponibili
Da: GreatBookPrices, Columbia, MD, U.S.A.
Condizione: New. Codice articolo 38646716-n
Quantità: 1 disponibili
Da: THE SAINT BOOKSTORE, Southport, Regno Unito
Paperback / softback. Condizione: New. New copy - Usually dispatched within 4 working days. 218. Codice articolo B9780727725264
Quantità: 1 disponibili
Da: Rarewaves USA, OSWEGO, IL, U.S.A.
Paperback. Condizione: New. Masonry walls are not isotropic; they have less strength in bending in the vertical direction than in the horizontal. The design of two-way spanning masonry panels under lateral loads is therefore complicated and tedious.The design tables in this book present a straightforward and practical approach to the design of rectangular lateral loaded panels under uniformly distributed loads. The tables give the ultimate load capacity of masonry panels of different sizes, properties and edge conditions. They cover both unreinforced and bed joint reinforced masonry panels. The basis of the preparation of the design tables is that presented in BS 5628 Part 1: 1992 and Part 2: 1995.The load tables will improve the efficiency of the design process and be a considerable asset to the practising engineer. Codice articolo LU-9780727725264
Quantità: 1 disponibili
Da: Ria Christie Collections, Uxbridge, Regno Unito
Condizione: New. In. Codice articolo ria9780727725264_new
Quantità: 1 disponibili
Da: GreatBookPricesUK, Woodford Green, Regno Unito
Condizione: New. Codice articolo 38646716-n
Quantità: 1 disponibili