Articoli correlati a Low-Temperature X-Ray Diffraction: Apparatus and Techniques

Low-Temperature X-Ray Diffraction: Apparatus and Techniques - Brossura

 
9781461587736: Low-Temperature X-Ray Diffraction: Apparatus and Techniques

Sinossi

Low-temperature X-ray diffraction (LTXRD) investigations offer many challenges to the diffractionist, not all of which are technical or scientific in nature. LTXRD studies can be frustrating: There are at least two reports of investigations ruined by the loss of crystals (grown with extreme difficulty) because of the widespread power failure and blackout in the northeastern United States in late 1965. LTXRD studies can cause discomfort: In several instances, "low temperatures" have been attained by opening all the windows in the X-ray laboratory. LTXRD studies can be dangerous: It was once reported that a crys­ tal was lost because a laboratory assistant fell down a flight of stairs and lay unconscious for about an hour on his way to refilling a liquid-nitrogen (LN2 ) dewar. This last report indicated the disposition of the crystal but not that of the laboratory assistant. However, in general, the results of low-temperature X-ray diffraction investigations cannot be obtained in any other manner, and one is well compensated for the effort expended in constructing and maintaining a low-temperature system. Crystal-structure analyses of solidified liquids and gases, phase transformation investigations, accurate crystal-structure analy­ ses and electron-density maps, thermal expansion measurements, and defect structure studies are a few of the many important applications of LTXRD.

Le informazioni nella sezione "Riassunto" possono far riferimento a edizioni diverse di questo titolo.

Contenuti

I: Introduction and Applications.- 1. Introduction.- 1.1. Historical Background.- 1.2. Cooling Apparatus.- 1.2.1. Provision for Cooling the Sample.- 1.2.1.1. Gas Stream.- 1.2.1.2. Conduction.- 1.2.1.3. Immersion.- 1.2.2. Control and Measurement of the Sample Temperature.- 1.2.3. Frost Prevention.- 1.3. Problem Areas in Designing LTXRD Apparatus.- 1.3.1. Absorption of X-Radiation.- 1.3.2. Size of Instrument.- 1.3.3. Frost Formation.- 1.3.4. Temperature Stability.- 1.3.5. Temperature Calibration.- 1.3.6. Misalignment.- 1.3.7. Sample.- 2. Applications.- 2.1. Solidified Liquids and Gases.- 2.2. Crystal-Structure Analysis.- 2.3. Electron-Density Distribution.- 2.4. Radiation Damage.- 2.5. Protein Crystallography.- 2.6. Defect Structures.- 2.7. Solid-Solid Phase Transition.- 2.7.1. Plastic Crystals.- 2.7.2. Metastable States.- 2.7.3. Phase Transitions.- 2.7.4. High-Pressure, Low-Temperature Studies.- 2.8. Thermal Expansion Coefficients and Precision Lattice Constants.- 2.9. Low-Temperature Powder Patterns.- 2.10. Other X-Ray Diffraction Applications.- 2.11. Application of Low-Temperature Methods to Other Types of Physical Measurements.- II: Low-Temperature X-Ray Diffraction Apparatus.- 3. Gas-Stream Cooling Apparatus.- 3.1. General Principles.- 3.1.1. Gas Generator.- 3.1.2. Transfer Lines and Nozzle.- 3.1.3. Temperature Control.- 3.1.4. Temperature Measurement.- 3.1.5. Frost Prevention.- 3.1.6. Rate of Cryogen Consumption.- 3.1.7. Gas-Stream Systems.- 3.1.8. Protection of X-Ray Apparatus.- 3.2. The Cold-Stream Nozzle.- 3.2.1. Size of the Opening.- 3.2.2. Outer Stream.- 3.2.3. Construction.- 3.2.4. Calibration of Temperature Gradient.- 3.3. Construction of a Simple Gas-Stream Apparatus.- 3.3.1. The Nozzle.- 3.3.2. The Heat Exchanger.- 3.3.3. Dry Gas.- 3.3.4. Temperature Control System.- 3.4 More Sophisticated Low-Temperature Gas-Stream Systems.- 3.4.1. Gas Stream from External Source.- 3.4.1.1. Mechanical Refrigeration.- 3.4.1.2. Heat Exchanger Immersed in Cold Bath.- 3.4.2. Gas Stream from Boiling Liquid Nitrogen.- 3.4.2.1. The Reservoir as Gas Generator.- 3.4.2.2. Reservoir Fills Small Gas Generator.- 3.4.2.3. Reservoir Fills Large Gas Generator.- 3.4.3. Gas Stream from Boiling Liquid Hydrogen or Liquid Helium.- 3.4.3.1. Weissenberg Goniometer.- 3.4.3.2. Single-Crystal Diffractometer.- 3.4.3.3. Rotation Camera.- 3.4.3.4. Powder Camera.- 3.4.4. Chambers Cooled by Gas Streams.- 3.5. Special Considerations for Specific X-Ray Diffraction Instruments.- 3.5.1. Weissenberg Goniometer.- 3.5.1.1. Back-Stream Method.- 3.5.1.2. Layer-Line Screens.- 3.5.1.3. Nozzle Support.- 3.5.1.4. Film Cassette.- 3.5.1.5. Rat-Plate Adapter.- 3.5.1.6. Upper-Level Photographs.- 3.5.2. Precession and Oscillation-Rotation Cameras.- 3.5.3. Single-Crystal Diffractometer.- 3.5.4. Powder Cameras and Diffractometer.- 3.6. Summary of Gas-Stream Methods.- 4. Conduction-Cooling Apparatus.- 4.1. General Principles.- 4.1.1. Introduction.- 4.1.2. Advantages of Conduction-Cooling Techniques.- 4.1.3. Disadvantages of Conduction-Cooling Techniques.- 4.1.3.1. Limitations on Data Collection.- 4.1.3.2. Absorption of X-Ray Beam.- 4.1.3.3. Thermal Gradients.- 4.1.3.4. Sample Preparation in Situ.- 4.2. Cryostat Design Requirements.- 4.2.1. Frost.- 4.2.2. Beryllium Windows.- 4.2.3. Temperature Gradients.- 4.2.4. Continuous-Flow Cryostat.- 4.3. Special Considerations for Individual X-Ray Instruments.- 4.4. Conduction Cooling via Liquefied Gases.- 4.4.1. Single-Crystal Cryostats for Use with Liquid Helium.- 4.4.2. Single-Crystal Cryostats for Use with Liquid Nitrogen.- 4.4.3. Powder-Sample Cryostats for Use with Liquid Helium or Liquid Nitrogen.- 4.4.3.1. Camera Apparatus.- 4.4.3.2. Liquid-Helium Cryostats for Powder Diffractometers.- 4.4.3.3. Liquid-Nitrogen Cryostats for Powder Diffractometers.- 4.4.3.4. Diffractometer Adapters.- 4.5. Conduction Cooling via Mechanical Refrigeration.- 4.6. Conduction Cooling via Thermoelectric Cooling.- 4.7. Conduction Cooling via Joule-Thomson Expansion.- 5. Immersion-Cooling Apparatus.- 5.1. General Principles.- 5.2. Immersion of Sample in Cold Liquid.- 5.2.1. Spraying.- 5.2.2. Dripping.- 5.2.3. Dipping.- 5.3. Immersion of Camera in Cold Liquid.- 5.4. Use of Cold Room.- III: Low-Temperature X-Ray Diffraction Techniques.- 6. Sample Preparation.- 6.1. Sample Preparation: Samples Solid at Room Temperature.- 6.1.1. Well-Behaved Solids.- 6.1.2. Unstable Samples.- 6.1.3. Protein Samples.- 6.1.4. Phase Transitions.- 6.2. Sample Preparation: Samples Liquid at Room Temperature.- 6.2.1. Crystallization Prior to Mounting.- 6.2.2. Crystallization Simultaneously with Mounting.- 6.2.3. Crystallization after Mounting.- 6.2.3.1. Filling and Sealing of Capillary Tubes.- 6.3. Sample Preparation: Samples Gaseous at Room Temperature.- 6.4. Preparation of Reactive or Radioactive Samples.- 6.5. Techniques for Preparing Randomly Aligned Powder Samples.- 7. Crystal-Growing-Techniques.- 7.1. Samples Solid at Room Temperature.- 7.2. Samples Liquid or Gaseous at Room Temperature.- 7.2.1. Crystal Growth at Low Temperatures Prior to Mounting the Crystal.- 7.2.2. Crystal Growth from the Melt; Sample in Capillary Tube.- 7.2.2.1. Growth Not on the X-Ray Instrument.- 7.2.2.2. Growth by Controlling the Temperature of a Gas Stream.- 7.2.2.3. External Heating.- 7.2.2.4. Special Problems.- 7.2.3. Crystal Growth from the Melt; Sample Not in Capillary Tube.- 7.3. Crystal Growth below the Temperature of Phase Transition.- 7.3.1. Slow Cooling.- 7.3.2. Annealing.- 7.3.3. Growth from Solution.- 7.4. Test for Centrosymmetric Crystal.- 8. Data Collection and Reduction.- 8.1. Temperature of Data Collection.- 8.1.1. Choice of Temperature.- 8.1.2. Temperature Calibration.- 8.2. Apparatus to Be Used for Data Collection.- 8.2.1. Protection of the X-Ray Instrument.- 8.2.2. Film at Low Temperature.- 8.2.3. Alignment and Calibration of Apparatus.- 8.3. Data Collection.- 8.3.1. Strategy of Data Collection.- 8.3.2. Check for Single Crystal.- 8.3.3. Alignment of Crystal.- 8.3.4. Radiation Damage.- 8.4. Data Reduction.- 8.4.1. Absorption Corrections.- 8.4.1.1. Powder Sample.- 8.4.1.2. Absorption by Windows and Sample Holder.- 8.4.1.3. Sample in Capillary Tube and Completely Bathed in the Beam.- 8.4.1.4. Sample in Capillary Tube and Larger than the Beam.- 8.4.1.5. Effect of Capillary Tube on Background Measurement.- 8.4.2. Refinement of Disordered Models.- 9. Future Trends in Low-Temperature X-Ray Diffraction.- IV: Appendices, Bibliography, and Index.- Appendix 1. Temperature Measurement.- Appendix 2. Cryogenic Liquids and Solids.- Appendix 3. Mechanical Refrigeration.- Appendix 4. Joule-Thomson Expansion Cooling.- Appendix 5. Thermoelectric Devices.- Appendix 6. Dewars.- Appendix 7. Transfer Lines.- Appendix 8. Insulation.- Appendix 9. Frost Prevention.- Appendix 10. Miscellaneous Gas-Flow Accessories.- Appendix 11. Low-Temperature Adhesives and Greases.- Appendix 12. List of Manufacturers of Low-Temperature Equipment and Accessories.- Appendix 13. Recommended Procedure for Describing Low-Temperature Apparatus in Publications.- B.1. Introduction.- B.2. Alphabetical Listing.- B.3. Apparatus Code-Number Listing.- B.4. Techniques and Applications Code-Number Listing.

Le informazioni nella sezione "Su questo libro" possono far riferimento a edizioni diverse di questo titolo.

Altre edizioni note dello stesso titolo

9780306309236: Low-Temperature X-Ray Diffraction: Apparatus and Techniques

Edizione in evidenza

ISBN 10:  0306309238 ISBN 13:  9780306309236
Casa editrice: Springer, 1976
Rilegato

Risultati della ricerca per Low-Temperature X-Ray Diffraction: Apparatus and Techniques

Foto dell'editore

Rudman, Reuben
Editore: Springer, 2012
ISBN 10: 1461587735 ISBN 13: 9781461587736
Nuovo Brossura

Da: Lucky's Textbooks, Dallas, TX, U.S.A.

Valutazione del venditore 5 su 5 stelle 5 stelle, Maggiori informazioni sulle valutazioni dei venditori

Condizione: New. Codice articolo ABLIING23Mar2716030038331

Contatta il venditore

Compra nuovo

EUR 52,67
Convertire valuta
Spese di spedizione: EUR 3,43
In U.S.A.
Destinazione, tempi e costi

Quantità: Più di 20 disponibili

Aggiungi al carrello

Foto dell'editore

Reuben Rudman
ISBN 10: 1461587735 ISBN 13: 9781461587736
Nuovo Paperback

Da: Grand Eagle Retail, Bensenville, IL, U.S.A.

Valutazione del venditore 5 su 5 stelle 5 stelle, Maggiori informazioni sulle valutazioni dei venditori

Paperback. Condizione: new. Paperback. Low-temperature X-ray diffraction (LTXRD) investigations offer many challenges to the diffractionist, not all of which are technical or scientific in nature. LTXRD studies can be frustrating: There are at least two reports of investigations ruined by the loss of crystals (grown with extreme difficulty) because of the widespread power failure and blackout in the northeastern United States in late 1965. LTXRD studies can cause discomfort: In several instances, "low temperatures" have been attained by opening all the windows in the X-ray laboratory. LTXRD studies can be dangerous: It was once reported that a crys tal was lost because a laboratory assistant fell down a flight of stairs and lay unconscious for about an hour on his way to refilling a liquid-nitrogen (LN2 ) dewar. This last report indicated the disposition of the crystal but not that of the laboratory assistant. However, in general, the results of low-temperature X-ray diffraction investigations cannot be obtained in any other manner, and one is well compensated for the effort expended in constructing and maintaining a low-temperature system. Crystal-structure analyses of solidified liquids and gases, phase transformation investigations, accurate crystal-structure analy ses and electron-density maps, thermal expansion measurements, and defect structure studies are a few of the many important applications of LTXRD. Low-temperature X-ray diffraction (LTXRD) investigations offer many challenges to the diffractionist, not all of which are technical or scientific in nature. Shipping may be from multiple locations in the US or from the UK, depending on stock availability. Codice articolo 9781461587736

Contatta il venditore

Compra nuovo

EUR 56,19
Convertire valuta
Spese di spedizione: GRATIS
In U.S.A.
Destinazione, tempi e costi

Quantità: 1 disponibili

Aggiungi al carrello

Immagini fornite dal venditore

Reuben Rudman
ISBN 10: 1461587735 ISBN 13: 9781461587736
Nuovo Taschenbuch
Print on Demand

Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germania

Valutazione del venditore 5 su 5 stelle 5 stelle, Maggiori informazioni sulle valutazioni dei venditori

Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Low-temperature X-ray diffraction (LTXRD) investigations offer many challenges to the diffractionist, not all of which are technical or scientific in nature. LTXRD studies can be frustrating: There are at least two reports of investigations ruined by the loss of crystals (grown with extreme difficulty) because of the widespread power failure and blackout in the northeastern United States in late 1965. LTXRD studies can cause discomfort: In several instances, 'low temperatures' have been attained by opening all the windows in the X-ray laboratory. LTXRD studies can be dangerous: It was once reported that a crys tal was lost because a laboratory assistant fell down a flight of stairs and lay unconscious for about an hour on his way to refilling a liquid-nitrogen (LN2 ) dewar. This last report indicated the disposition of the crystal but not that of the laboratory assistant. However, in general, the results of low-temperature X-ray diffraction investigations cannot be obtained in any other manner, and one is well compensated for the effort expended in constructing and maintaining a low-temperature system. Crystal-structure analyses of solidified liquids and gases, phase transformation investigations, accurate crystal-structure analy ses and electron-density maps, thermal expansion measurements, and defect structure studies are a few of the many important applications of LTXRD. 364 pp. Englisch. Codice articolo 9781461587736

Contatta il venditore

Compra nuovo

EUR 53,49
Convertire valuta
Spese di spedizione: EUR 23,00
Da: Germania a: U.S.A.
Destinazione, tempi e costi

Quantità: 2 disponibili

Aggiungi al carrello

Immagini fornite dal venditore

Reuben Rudman
Editore: Springer US, 2012
ISBN 10: 1461587735 ISBN 13: 9781461587736
Nuovo Brossura
Print on Demand

Da: moluna, Greven, Germania

Valutazione del venditore 4 su 5 stelle 4 stelle, Maggiori informazioni sulle valutazioni dei venditori

Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Low-temperature X-ray diffraction (LTXRD) investigations offer many challenges to the diffractionist, not all of which are technical or scientific in nature. LTXRD studies can be frustrating: There are at least two reports of investigations ruined by the lo. Codice articolo 4200611

Contatta il venditore

Compra nuovo

EUR 48,37
Convertire valuta
Spese di spedizione: EUR 48,99
Da: Germania a: U.S.A.
Destinazione, tempi e costi

Quantità: Più di 20 disponibili

Aggiungi al carrello

Immagini fornite dal venditore

Reuben Rudman
ISBN 10: 1461587735 ISBN 13: 9781461587736
Nuovo Taschenbuch
Print on Demand

Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germania

Valutazione del venditore 5 su 5 stelle 5 stelle, Maggiori informazioni sulle valutazioni dei venditori

Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Low-temperature X-ray diffraction (LTXRD) investigations offer many challenges to the diffractionist, not all of which are technical or scientific in nature. LTXRD studies can be frustrating: There are at least two reports of investigations ruined by the loss of crystals (grown with extreme difficulty) because of the widespread power failure and blackout in the northeastern United States in late 1965. LTXRD studies can cause discomfort: In several instances, 'low temperatures' have been attained by opening all the windows in the X-ray laboratory. LTXRD studies can be dangerous: It was once reported that a crys tal was lost because a laboratory assistant fell down a flight of stairs and lay unconscious for about an hour on his way to refilling a liquid-nitrogen (LN2 ) dewar. This last report indicated the disposition of the crystal but not that of the laboratory assistant. However, in general, the results of low-temperature X-ray diffraction investigations cannot be obtained in any other manner, and one is well compensated for the effort expended in constructing and maintaining a low-temperature system. Crystal-structure analyses of solidified liquids and gases, phase transformation investigations, accurate crystal-structure analy ses and electron-density maps, thermal expansion measurements, and defect structure studies are a few of the many important applications of LTXRD.Springer Verlag GmbH, Tiergartenstr. 17, 69121 Heidelberg 364 pp. Englisch. Codice articolo 9781461587736

Contatta il venditore

Compra nuovo

EUR 53,49
Convertire valuta
Spese di spedizione: EUR 60,00
Da: Germania a: U.S.A.
Destinazione, tempi e costi

Quantità: 1 disponibili

Aggiungi al carrello

Immagini fornite dal venditore

Reuben Rudman
Editore: Springer US, 2012
ISBN 10: 1461587735 ISBN 13: 9781461587736
Nuovo Taschenbuch

Da: AHA-BUCH GmbH, Einbeck, Germania

Valutazione del venditore 5 su 5 stelle 5 stelle, Maggiori informazioni sulle valutazioni dei venditori

Taschenbuch. Condizione: Neu. Druck auf Anfrage Neuware - Printed after ordering - Low-temperature X-ray diffraction (LTXRD) investigations offer many challenges to the diffractionist, not all of which are technical or scientific in nature. LTXRD studies can be frustrating: There are at least two reports of investigations ruined by the loss of crystals (grown with extreme difficulty) because of the widespread power failure and blackout in the northeastern United States in late 1965. LTXRD studies can cause discomfort: In several instances, 'low temperatures' have been attained by opening all the windows in the X-ray laboratory. LTXRD studies can be dangerous: It was once reported that a crys tal was lost because a laboratory assistant fell down a flight of stairs and lay unconscious for about an hour on his way to refilling a liquid-nitrogen (LN2 ) dewar. This last report indicated the disposition of the crystal but not that of the laboratory assistant. However, in general, the results of low-temperature X-ray diffraction investigations cannot be obtained in any other manner, and one is well compensated for the effort expended in constructing and maintaining a low-temperature system. Crystal-structure analyses of solidified liquids and gases, phase transformation investigations, accurate crystal-structure analy ses and electron-density maps, thermal expansion measurements, and defect structure studies are a few of the many important applications of LTXRD. Codice articolo 9781461587736

Contatta il venditore

Compra nuovo

EUR 59,97
Convertire valuta
Spese di spedizione: EUR 62,64
Da: Germania a: U.S.A.
Destinazione, tempi e costi

Quantità: 1 disponibili

Aggiungi al carrello

Foto dell'editore

Rudman, Reuben
Editore: Springer, 2012
ISBN 10: 1461587735 ISBN 13: 9781461587736
Nuovo Brossura

Da: Ria Christie Collections, Uxbridge, Regno Unito

Valutazione del venditore 5 su 5 stelle 5 stelle, Maggiori informazioni sulle valutazioni dei venditori

Condizione: New. In. Codice articolo ria9781461587736_new

Contatta il venditore

Compra nuovo

EUR 111,60
Convertire valuta
Spese di spedizione: EUR 13,79
Da: Regno Unito a: U.S.A.
Destinazione, tempi e costi

Quantità: Più di 20 disponibili

Aggiungi al carrello

Foto dell'editore

Rudman, Reuben
Editore: Springer 2012-06, 2012
ISBN 10: 1461587735 ISBN 13: 9781461587736
Nuovo PF

Da: Chiron Media, Wallingford, Regno Unito

Valutazione del venditore 4 su 5 stelle 4 stelle, Maggiori informazioni sulle valutazioni dei venditori

PF. Condizione: New. Codice articolo 6666-IUK-9781461587736

Contatta il venditore

Compra nuovo

EUR 112,49
Convertire valuta
Spese di spedizione: EUR 17,83
Da: Regno Unito a: U.S.A.
Destinazione, tempi e costi

Quantità: 10 disponibili

Aggiungi al carrello

Foto dell'editore

Reuben Rudman
ISBN 10: 1461587735 ISBN 13: 9781461587736
Nuovo Paperback

Da: AussieBookSeller, Truganina, VIC, Australia

Valutazione del venditore 5 su 5 stelle 5 stelle, Maggiori informazioni sulle valutazioni dei venditori

Paperback. Condizione: new. Paperback. Low-temperature X-ray diffraction (LTXRD) investigations offer many challenges to the diffractionist, not all of which are technical or scientific in nature. LTXRD studies can be frustrating: There are at least two reports of investigations ruined by the loss of crystals (grown with extreme difficulty) because of the widespread power failure and blackout in the northeastern United States in late 1965. LTXRD studies can cause discomfort: In several instances, "low temperatures" have been attained by opening all the windows in the X-ray laboratory. LTXRD studies can be dangerous: It was once reported that a crys tal was lost because a laboratory assistant fell down a flight of stairs and lay unconscious for about an hour on his way to refilling a liquid-nitrogen (LN2 ) dewar. This last report indicated the disposition of the crystal but not that of the laboratory assistant. However, in general, the results of low-temperature X-ray diffraction investigations cannot be obtained in any other manner, and one is well compensated for the effort expended in constructing and maintaining a low-temperature system. Crystal-structure analyses of solidified liquids and gases, phase transformation investigations, accurate crystal-structure analy ses and electron-density maps, thermal expansion measurements, and defect structure studies are a few of the many important applications of LTXRD. Low-temperature X-ray diffraction (LTXRD) investigations offer many challenges to the diffractionist, not all of which are technical or scientific in nature. Shipping may be from our Sydney, NSW warehouse or from our UK or US warehouse, depending on stock availability. Codice articolo 9781461587736

Contatta il venditore

Compra nuovo

EUR 109,08
Convertire valuta
Spese di spedizione: EUR 31,77
Da: Australia a: U.S.A.
Destinazione, tempi e costi

Quantità: 1 disponibili

Aggiungi al carrello