Mechanical cardiovascular assist devices must be properly designed to avoid damage to the blood they contact. The factors that affect the hemocompatibility of a cardiovascular assist device include three major non-physiological components the material, fluid flow paths, and flow related stresses, - as well as the device interaction with the native vasculature. Furthermore, the interaction of the device with the blood is not static. Foreign surfaces activate blood components including platelets, leukocytes and the coagulation cascade. Thrombus formation on the surface of the device can alter the fluid dynamics in a manner that causes erythrocyte damage ranging from significant hemolysis to sub-lethal trauma that can take many days to weeks to develop into a significant clinical problem. This sub-lethal blood trauma is not easily detectable without special equipment, which is typically unavailable in routine clinical practice. Surveillance for blood damage is often sub-optimal in the clinical setting, but once clinically relevant hemolysis occurs, crucial decisions - device removal, replacement, or additional medical therapies including surgery or plasmapheresis - that take into account the risk/benefit of intervention must be quickly evaluated. The various preclinical designs and testing, surgical considerations, available surveillance techniques, and clinical consequences will be discussed using recent and historical case reports to highlight key points.
Le informazioni nella sezione "Riassunto" possono far riferimento a edizioni diverse di questo titolo.
PhD; University of Pittsburgh
Le informazioni nella sezione "Su questo libro" possono far riferimento a edizioni diverse di questo titolo.
EUR 17,56 per la spedizione da U.S.A. a Italia
Destinazione, tempi e costiEUR 1,97 per la spedizione da U.S.A. a Italia
Destinazione, tempi e costiDa: PBShop.store US, Wood Dale, IL, U.S.A.
HRD. Condizione: New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Codice articolo L1-9781606507834
Quantità: Più di 20 disponibili
Da: PBShop.store UK, Fairford, GLOS, Regno Unito
HRD. Condizione: New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Codice articolo L1-9781606507834
Quantità: Più di 20 disponibili
Da: Ria Christie Collections, Uxbridge, Regno Unito
Condizione: New. In. Codice articolo ria9781606507834_new
Quantità: Più di 20 disponibili
Da: moluna, Greven, Germania
Condizione: New. Über den AutorPhD University of PittsburghKlappentextrnrnMechanical cardiovascular assist devices must be properly designed to avoid damage to the blood they contact. The factors that affect the hemocompatibilit. Codice articolo 448151523
Quantità: Più di 20 disponibili
Da: California Books, Miami, FL, U.S.A.
Condizione: New. Codice articolo I-9781606507834
Quantità: Più di 20 disponibili
Da: GreatBookPrices, Columbia, MD, U.S.A.
Condizione: New. Codice articolo 23685793-n
Quantità: Più di 20 disponibili
Da: GreatBookPricesUK, Woodford Green, Regno Unito
Condizione: New. Codice articolo 23685793-n
Quantità: Più di 20 disponibili
Da: THE SAINT BOOKSTORE, Southport, Regno Unito
Hardback. Condizione: New. This item is printed on demand. New copy - Usually dispatched within 5-9 working days 290. Codice articolo C9781606507834
Quantità: Più di 20 disponibili
Da: GreatBookPrices, Columbia, MD, U.S.A.
Condizione: As New. Unread book in perfect condition. Codice articolo 23685793
Quantità: Più di 20 disponibili
Da: GreatBookPricesUK, Woodford Green, Regno Unito
Condizione: As New. Unread book in perfect condition. Codice articolo 23685793
Quantità: Più di 20 disponibili