Articoli correlati a Numerical Flow Simulation in FDA's "Critical...

Numerical Flow Simulation in FDA's "Critical Path" benchmark blood pump - Brossura

 
9783346238078: Numerical Flow Simulation in FDA's "Critical Path" benchmark blood pump

Sinossi

Master's Thesis from the year 2019 in the subject Engineering - Mechanical Engineering, grade: 1.3, University of Rostock, course: Computational Science and Engineering, language: English, abstract: The work focuses on the analysis of the flow fields in the Food and Drug Administrations (FDA) 'Critical Path' benchmark blood pump. The CAD model of the pump is an opensource material, so the thesis works started with the mesh generation. A block-structured hexahedral mesh has been created using ANSYS ICEM CFD 15.0. An unsteady (URANS) incompressible blood flow simulation has been performed using k-ω SST turbulence model, with one of the operating conditions prescribed by the experimental literature. The simulations were performed using ANSYS CFX 19.1 solver. The validated results for the flow field show promising results in the blade passage region and the diffuser regions but the pressure head obtained has some discrepancies which were analyzed and justified. In addition, a study on hemolysis prediction using Power Law was performed, and the blood damage values of the benchmark blood pump were calculated for the stress-based model in the Eulerian approach. The role of Computational Fluid Dynamics (CFD) in the biomedical field has increased a lot in recent years. The problems related to biocompatibility in medical and biological industries capture the attention of CFD engineers. One such biocompatible device is a Ventricular Assist Device (VAD). The development phase of VAD's associates CFD to make it more robust. VADs generally incorporated with blood pumps, so it is essential to examine the dynamics of the blood flow in the pump and also to analyze the damages concerned with the blood cells. The U.S. Food and Drug Administration (FDA)and the Center of Devices and Radiological Health (CDRH) have sponsored certain CFD'round-robins' to validate the efficiency of computer simulations in biomedical applications. The 'Computational round-robin #2' concerns with a 'Crit

Le informazioni nella sezione "Riassunto" possono far riferimento a edizioni diverse di questo titolo.

EUR 11,00 per la spedizione da Germania a Italia

Destinazione, tempi e costi

Risultati della ricerca per Numerical Flow Simulation in FDA's "Critical...

Immagini fornite dal venditore

Krishnaraj Narayanaswamy
Editore: GRIN Verlag Feb 2021, 2021
ISBN 10: 3346238075 ISBN 13: 9783346238078
Nuovo Taschenbuch
Print on Demand

Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germania

Valutazione del venditore 5 su 5 stelle 5 stelle, Maggiori informazioni sulle valutazioni dei venditori

Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Master's Thesis from the year 2019 in the subject Engineering - Mechanical Engineering, grade: 1.3, University of Rostock, course: Computational Science and Engineering, language: English, abstract: The work focuses on the analysis of the flow fields in the Food and Drug Administrations (FDA) 'Critical Path' benchmark blood pump. The CAD model of the pump is an opensource material, so the thesis works started with the mesh generation. A block-structured hexahedral mesh has been created using ANSYS ICEM CFD 15.0. An unsteady (URANS) incompressible blood flow simulation has been performed using k- SST turbulence model, with one of the operating conditions prescribed by the experimental literature. The simulations were performed using ANSYS CFX 19.1 solver. The validated results for the flow field show promising results in the blade passage region and the diffuser regions but the pressure head obtained has some discrepancies which were analyzed and justified. In addition, a study on hemolysis prediction using Power Law was performed, and the blood damage values of the benchmark blood pump were calculated for the stress-based model in the Eulerian approach. The role of Computational Fluid Dynamics (CFD) in the biomedical field has increased a lot in recent years. The problems related to biocompatibility in medical and biological industries capture the attention of CFD engineers. One such biocompatible device is a Ventricular Assist Device (VAD). The development phase of VAD's associates CFD to make it more robust. VADs generally incorporated with blood pumps, so it is essential to examine the dynamics of the blood flow in the pump and also to analyze the damages concerned with the blood cells. The U.S. Food and Drug Administration (FDA)and the Center of Devices and Radiological Health (CDRH) have sponsored certain CFD'round-robins' to validate the efficiency of computer simulations in biomedical applications. The 'Computational round-robin #2' concerns with a 'Critical Path' benchmark blood Pump. 60 pp. Englisch. Codice articolo 9783346238078

Contatta il venditore

Compra nuovo

EUR 27,95
Convertire valuta
Spese di spedizione: EUR 11,00
Da: Germania a: Italia
Destinazione, tempi e costi

Quantità: 2 disponibili

Aggiungi al carrello

Immagini fornite dal venditore

Krishnaraj Narayanaswamy
Editore: GRIN Verlag, 2021
ISBN 10: 3346238075 ISBN 13: 9783346238078
Nuovo Taschenbuch

Da: AHA-BUCH GmbH, Einbeck, Germania

Valutazione del venditore 5 su 5 stelle 5 stelle, Maggiori informazioni sulle valutazioni dei venditori

Taschenbuch. Condizione: Neu. Druck auf Anfrage Neuware - Printed after ordering - Master's Thesis from the year 2019 in the subject Engineering - Mechanical Engineering, grade: 1.3, University of Rostock, course: Computational Science and Engineering, language: English, abstract: The work focuses on the analysis of the flow fields in the Food and Drug Administrations (FDA) 'Critical Path' benchmark blood pump. The CAD model of the pump is an opensource material, so the thesis works started with the mesh generation. A block-structured hexahedral mesh has been created using ANSYS ICEM CFD 15.0. An unsteady (URANS) incompressible blood flow simulation has been performed using k- SST turbulence model, with one of the operating conditions prescribed by the experimental literature. The simulations were performed using ANSYS CFX 19.1 solver. The validated results for the flow field show promising results in the blade passage region and the diffuser regions but the pressure head obtained has some discrepancies which were analyzed and justified. In addition, a study on hemolysis prediction using Power Law was performed, and the blood damage values of the benchmark blood pump were calculated for the stress-based model in the Eulerian approach. The role of Computational Fluid Dynamics (CFD) in the biomedical field has increased a lot in recent years. The problems related to biocompatibility in medical and biological industries capture the attention of CFD engineers. One such biocompatible device is a Ventricular Assist Device (VAD). The development phase of VAD's associates CFD to make it more robust. VADs generally incorporated with blood pumps, so it is essential to examine the dynamics of the blood flow in the pump and also to analyze the damages concerned with the blood cells. The U.S. Food and Drug Administration (FDA)and the Center of Devices and Radiological Health (CDRH) have sponsored certain CFD'round-robins' to validate the efficiency of computer simulations in biomedical applications. The 'Computational round-robin #2' concerns with a 'Critical Path' benchmark blood Pump. Codice articolo 9783346238078

Contatta il venditore

Compra nuovo

EUR 27,95
Convertire valuta
Spese di spedizione: EUR 14,99
Da: Germania a: Italia
Destinazione, tempi e costi

Quantità: 1 disponibili

Aggiungi al carrello

Immagini fornite dal venditore

Krishnaraj Narayanaswamy
Editore: GRIN Verlag Feb 2021, 2021
ISBN 10: 3346238075 ISBN 13: 9783346238078
Nuovo Taschenbuch

Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germania

Valutazione del venditore 5 su 5 stelle 5 stelle, Maggiori informazioni sulle valutazioni dei venditori

Taschenbuch. Condizione: Neu. Neuware -Master's Thesis from the year 2019 in the subject Engineering - Mechanical Engineering, grade: 1.3, University of Rostock, course: Computational Science and Engineering, language: English, abstract: The work focuses on the analysis of the flow fields in the Food and Drug Administrations (FDA) 'Critical Path' benchmark blood pump. The CAD model of the pump is an opensource material, so the thesis works started with the mesh generation. A block-structured hexahedral mesh has been created using ANSYS ICEM CFD 15.0. An unsteady (URANS) incompressible blood flow simulation has been performed using k-¿ SST turbulence model, with one of the operating conditions prescribed by the experimental literature. The simulations were performed using ANSYS CFX 19.1 solver. The validated results for the flow field show promising results in the blade passage region and the diffuser regions but the pressure head obtained has some discrepancies which were analyzed and justified. In addition, a study on hemolysis prediction using Power Law was performed, and the blood damage values of the benchmark blood pump were calculated for the stress-based model in the Eulerian approach. The role of Computational Fluid Dynamics (CFD) in the biomedical field has increased a lot in recent years. The problems related to biocompatibility in medical and biological industries capture the attention of CFD engineers. One such biocompatible device is a Ventricular Assist Device (VAD). The development phase of VAD's associates CFD to make it more robust. VADs generally incorporated with blood pumps, so it is essential to examine the dynamics of the blood flow in the pump and also to analyze the damages concerned with the blood cells. The U.S. Food and Drug Administration (FDA)and the Center of Devices and Radiological Health (CDRH) have sponsored certain CFD'round-robins' to validate the efficiency of computer simulations in biomedical applications. The ¿Computational round-robin #2¿ concerns with a 'Critical Path' benchmark blood Pump.Books on Demand GmbH, Überseering 33, 22297 Hamburg 60 pp. Englisch. Codice articolo 9783346238078

Contatta il venditore

Compra nuovo

EUR 27,95
Convertire valuta
Spese di spedizione: EUR 15,00
Da: Germania a: Italia
Destinazione, tempi e costi

Quantità: 2 disponibili

Aggiungi al carrello

Foto dell'editore

Narayanaswamy, Krishnaraj
Editore: Grin Verlag, 2021
ISBN 10: 3346238075 ISBN 13: 9783346238078
Nuovo Brossura

Da: California Books, Miami, FL, U.S.A.

Valutazione del venditore 5 su 5 stelle 5 stelle, Maggiori informazioni sulle valutazioni dei venditori

Condizione: New. Codice articolo I-9783346238078

Contatta il venditore

Compra nuovo

EUR 45,21
Convertire valuta
Spese di spedizione: EUR 7,75
Da: U.S.A. a: Italia
Destinazione, tempi e costi

Quantità: Più di 20 disponibili

Aggiungi al carrello

Immagini fornite dal venditore

Krishnaraj Narayanaswamy
Editore: GRIN Verlag, 2021
ISBN 10: 3346238075 ISBN 13: 9783346238078
Nuovo Taschenbuch

Da: preigu, Osnabrück, Germania

Valutazione del venditore 5 su 5 stelle 5 stelle, Maggiori informazioni sulle valutazioni dei venditori

Taschenbuch. Condizione: Neu. Numerical Flow Simulation in FDA's "Critical Path" benchmark blood pump | Krishnaraj Narayanaswamy | Taschenbuch | Englisch | 2021 | GRIN Verlag | EAN 9783346238078 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. Codice articolo 118950263

Contatta il venditore

Compra nuovo

EUR 27,95
Convertire valuta
Spese di spedizione: EUR 45,00
Da: Germania a: Italia
Destinazione, tempi e costi

Quantità: 5 disponibili

Aggiungi al carrello