Articoli correlati a Methods of Preparation for Electron Microscopy: An...

Methods of Preparation for Electron Microscopy: An Introduction for the Biomedical Sciences - Brossura

 
9783540175926: Methods of Preparation for Electron Microscopy: An Introduction for the Biomedical Sciences

Sinossi

In 1939, when the electron optics laboratory of Siemens & Halske Inc. began to manufacture the first electron microscopes, the biological and medical profes­ sions had an unexpected instrument at their disposal which exceeded the reso­ lution of the light microscope by more than a hundredfold. The immediate and broad application of this new tool was complicated by the overwhelming prob­ lems inherent in specimen preparation for the investigation of cellular struc­ tures. The microtechniques applied in light microscopy were no longer appli­ cable, since even the thinnest paraffin layers could not be penetrated by electrons. Many competent biological and medical research workers expressed their anxiety that objects in high vacuum would be modified due to complete dehydration and the absorbed electron energy would eventually cause degrada­ tion to rudimentary carbon backbones. It also seemed questionable as to whether it would be possible to prepare thin sections of approximately 0. 5 11m from heterogeneous biological specimens. Thus one was suddenly in posses­ sion of a completely unique instrument which, when compared with the light microscope, allowed a 10-100-fold higher resolution, yet a suitable preparation methodology was lacking. This sceptical attitude towards the application of electron microscopy in bi­ ology and medicine was supported simultaneously by the general opinion of colloid chemists, who postulated that in the submicroscopic region of living structures no stable building blocks existed which could be revealed with this apparatus.

Le informazioni nella sezione "Riassunto" possono far riferimento a edizioni diverse di questo titolo.

Contenuti

1 An Introduction to Electron Microscopy (EM).- 1.1 Imaging Methods in Electron Microscopy.- 1.1.1 Conventional Transmission Electron Microscopy (TEM).- 1.1.1.1 Bright Field Electron Microscopy.- 1.1.1.2 Low Dose Transmission Electron Microscopy.- 1.1.1.3 Dark Field Electron Microscopy.- 1.1.2 Conventional Scanning Electron Microscopy (SEM).- 1.1.2.1 Imaging with Secondary and Back-Scattered Electrons.- 1.1.2.2 Scanning Electron Microscopy at Low Accelerating Voltages.- 1.2 Preparation Procedures in TEM.- 1.2.1 Overview.- 1.2.2 Structural Preservation During Fixation, Dehydration and Embedding of Biological Objects.- 1.3 Imaging Problems.- 1.3.1 On the Interpretation of TEM Images.- 1.3.2 On the Interpretation of SEM Images.- 1.4 Support Films.- 1.4.1 Grids for TEM and Their Pretreatment.- 1.4.2 Formvar Films.- 1.4.3 Collodion Films.- 1.4.4 Hydrophilisation of Films.- 1.4.5 Support Films with Holes.- 1.4.6 Carbon Films.- 2 Methods for TEM.- 2.1 Fixation, Dehydration and Embedding.- 2.1.1 Chemical Fixations.- 2.1.1.1 General Comments.- 2.1.1.2 Fixatives: Properties and Preparation.- 2.1.1.3 Composition of Fixation Solutions.- 2.1.1.4 The Fixation of Animal Cells.- 2.1.1.5 The Fixation of Plants and Microorganisms.- 2.1.1.6 The Fixation of Isolated Organelles.- 2.1.1.7 Fixing for Immunocytochemistry.- 2.1.2 Dehydration.- 2.1.3 Embedding.- 2.1.3.1 Embedding Media: General Usage and Precautions.- 2.1.3.2 Conventional Embedding.- 2.1.3.3 Water-Soluble Embedding Media.- 2.1.3.4 Embedding for Immunocytochemistry.- 2.1.3.5 Embedding Moulds and Specimen Orientation.- 2.1.3.6 Embedding of Monolayer Cell Cultures.- 2.2 Ultramicrotomy.- 2.2.1 Trimming of Blocks.- 2.2.1.1 General.- 2.2.1.2 Controlled Trimming: Production and Staining of Semi-Thin Sections.- 2.2.2 Preparing Glass Knives.- 2.2.2.1 Preparation of the Glass Strips.- 2.2.2.2 Breaking Glass Squares.- 2.2.2.3 Making Knives.- 2.2.2.4 Judging the Quality of a Glass Knife.- 2.2.2.5 Attaching Troughs.- 2.2.2.6 Storing Glass Knives.- 2.2.3 Diamond Knives and Their Care.- 2.2.4 Conventional Sectioning.- 2.2.4.1 Trough Liquids.- 2.2.4.2 Using an Ultramicrotome.- 2.2.4.3 Section Thickness.- 2.2.4.4 Picking Up Sections.- 2.2.4.5 Sectioning Problems.- 2.2.5 Cryo-ultramicrotomy.- 2.2.5.1 Freezing the Sample.- 2.2.5.2 Sectioning the Frozen Sample.- 2.2.5.3 Picking up Frozen Sections.- 2.2.6 Staining Sections.- 2.2.6.1 Staining Solutions.- 2.2.6.2 Procedure for Double Staining Sections.- 2.2.6.3 Staining Sections of Material Embedded for Immunocytochemical Purposes.- 2.2.6.4 Staining Cryosections.- 2.2.6.5 Block Staining.- 2.3 Macromolecular EM.- 2.3.1 Isolated Proteins and Protein Aggregates.- 2.3.1.1 Preparation of Specimens.- 2.3.1.2 Negative Staining Techniques.- 2.3.1.3 High Resolution Metal Shadowing.- 2.3.1.4 Preparation and Imaging of Two-Dimensional Protein Crystals.- 2.3.1.5 Making a “Tilt Series”.- 2.3.2 Isolated Nucleic Acids.- 2.3.2.1 Problems and Aims.- 2.3.2.2 Specimen Preparation.- 2.3.2.3 Spreading and Diffusion Techniques Which Employ Cytochrome c.- 2.3.2.4 “BAC” Technique.- 2.3.2.5 Partial Denaturating, Heteroduplex and R-Loop Techniques.- 2.3.3 Nucleic Acid-Protein Complexes.- 2.3.3.1 Specimen Preparation.- 2.3.3.2 Production and Staining of NA-Protein Complexes.- 2.4 Immunoelectron Microscopy (I EM).- 2.4.1 Principle Requirements.- 2.4.1.1 Antigens.- 2.4.1.2 Antibodies.- 2.4.2 Labelling of Antigens in Cells and Cell Fractions.- 2.4.2.1 Ferritin-Labelled Antibodies.- 2.4.2.2 Immunolabelling with Protein A-Gold.- 2.4.3 Localization of Protein Subunits with Specific IgG Antibodies.- 2.4.3.1 Preparation and Visualization of the Protein-Antibody Complex.- 2.5 Autoradiography.- 2.5.1 General Background.- 2.5.1.1 Physical Basis.- 2.5.1.2 Chemical Basis.- 2.5.2 Choice and Dosis of Radioactive Compounds.- 2.5.2.1 Choosing a Radioactive Precursor.- 2.5.2.2 Dosage.- 2.5.3 Working with Isotopes-Radiation Protection.- 2.5.4 Preparation of Radio-Labelled Cells/Tissues for Electron Microscopy.- 2.5.5 Photographic Emulsions and Autoradiography.- 2.5.5.1 Apparatus Required.- 2.5.5.2 Choice of Emulsion; Consequences for Resolution.- 2.5.5.3 Preparation of Sections.- 2.5.5.4 LM Autoradiography.- 2.5.5.5 Emulsion, Coating Techniques.- 2.5.6 Exposing, Developing and Fixing.- 2.5.6.1 Exposing.- 2.5.6.2 Developing and Fixing.- 2.5.6.3 Future Developments in Autoradiography.- 2.6 Freeze (Fracturing) Etching.- 2.6.1 Introduction.- 2.6.2 Freezing.- 2.6.2.1 Theoretical Background.- 2.6.2.2 Cyroprotectants.- 2.6.2.3 Supports.- 2.6.2.4 Cryogens and Freezing Methods.- 2.6.2.5 Storage of Frozen Specimens.- 2.6.3 Fracturing.- 2.6.3.1 Transfer of the Object into the Vacuum Recipient.- 2.6.3.2 The Fracturing Process.- 2.6.3.3 Fracture Planes in Biological Material.- 2.6.4 Etching.- 2.6.4.1 The Purpose of Etching.- 2.6.4.2 Theory and Practice.- 2.6.5 Shadowing and Replica Formation.- 2.6.5.1 Resistance-Heating Evaporation.- 2.6.5.2 Electron Beam Evaporation.- 2.6.5.3 Measurement of Replica Thickness.- 2.6.6 Cleaning the Replica.- 2.6.7 Artifacts in Freeze Etching.- 2.6.8 Using a Freeze-Etch Machine: a Practical Description.- 3 Methods for SEM.- 3.1 Conventional Methods of Preparation.- 3.1.1 Introduction.- 3.1.2 Specimen Size; Handling Specimens and Exposing Surfaces.- 3.1.2.1 Cleaning Surfaces.- 3.1.3 Stabilization.- 3.1.3.1 Chemical Fixations.- 3.1.3.2 Cryofixation.- 3.1.4 Dehydration.- 3.1.5 Drying.- 3.1.5.1 Critical Point Drying.- 3.1.5.2 Freeze Drying.- 3.1.6 Mounting Specimens.- 3.1.7 Increasing Conductivity.- 3.1.7.1 Sputtering.- 3.1.7.2 Evaporating.- 3.2 Storage of Specimens.- 3.3 Demonstration of Surfaces via Replicas and Casts.- 3.4 Visualization of Internal Surfaces Through Sectioning and Dry-Fracturing (Dry-Cleaving).- 3.5 Element Analysis.- 4 Evaluation of Micrographs.- 4.1 Morphometry.- 4.1.1 Problems and Solutions.- 4.1.2 Measurement: Some General Points.- 4.1.3 Stereology: General Principles.- 4.1.4 Collection and Evaluation of Data; Statistical Treatments.- 4.2 Averaging and Image Reconstruction.- 4.2.1 General.- 4.2.2 Markham Rotation.- 4.2.3 Principles of Light Optical Diffraction.- 4.2.4 Principles of Computer-Assisted Image Reconstruction.- Appendix: Buffers in Electron Microscopy.

Product Description

Book by Robinson David G Ehlers Ulrich Herken Rainer Herrm

Le informazioni nella sezione "Su questo libro" possono far riferimento a edizioni diverse di questo titolo.

Compra usato

Condizioni: molto buono
XVII, 190 S. : 62 Ill., graph....
Visualizza questo articolo

EUR 12,50 per la spedizione da Germania a Italia

Destinazione, tempi e costi

EUR 9,70 per la spedizione da Germania a Italia

Destinazione, tempi e costi

Altre edizioni note dello stesso titolo

9780387175928: Methods of Preparation for Electron Microscopy: An Introduction for the Biomedical Sciences

Edizione in evidenza

ISBN 10:  038717592X ISBN 13:  9780387175928
Brossura

Risultati della ricerca per Methods of Preparation for Electron Microscopy: An...

Immagini fornite dal venditore

Robinson, David G. [Mitverf.], U. Ehlers R. Herken a. o.:
ISBN 10: 354017592X ISBN 13: 9783540175926
Antico o usato Brossura

Da: Kepler-Buchversand Huong Bach, Weil der Stadt, Germania

Valutazione del venditore 4 su 5 stelle 4 stelle, Maggiori informazioni sulle valutazioni dei venditori

Condizione: Gut. XVII, 190 S. : 62 Ill., graph. Darst. Gebraucht; Einband minimal berieben, ansonten guter Zustand. Aus dem Inhalt: An Introduction to Electron Microscops (EM) / Methods for TEM / Methods for SEM / Evaluation of Micrographs / Appendix: Buffers in Electron Microscopy / Subject Index. Sprache: Englisch Gewicht in Gramm: 350. Codice articolo 60299

Contatta il venditore

Compra usato

EUR 29,90
Convertire valuta
Spese di spedizione: EUR 12,50
Da: Germania a: Italia
Destinazione, tempi e costi

Quantità: 1 disponibili

Aggiungi al carrello

Foto dell'editore

Robinson, D.G. et al
Editore: Springer, 1987
ISBN 10: 354017592X ISBN 13: 9783540175926
Antico o usato Brossura

Da: Anybook.com, Lincoln, Regno Unito

Valutazione del venditore 5 su 5 stelle 5 stelle, Maggiori informazioni sulle valutazioni dei venditori

Condizione: Good. This is an ex-library book and may have the usual library/used-book markings inside.This book has soft covers. Clean from markings. In good all round condition. Please note the Image in this listing is a stock photo and may not match the covers of the actual item,500grams, ISBN:354017592X. Codice articolo 9819528

Contatta il venditore

Compra usato

EUR 37,72
Convertire valuta
Spese di spedizione: EUR 9,76
Da: Regno Unito a: Italia
Destinazione, tempi e costi

Quantità: 1 disponibili

Aggiungi al carrello

Foto dell'editore

Robinson, David G.,Ehlers, Ulrich,Herken, Rainer,Herrmann, Bernd,Mayer, Frank,Schürmann, Friedrich-Wilhelm
Editore: Springer, 1987
ISBN 10: 354017592X ISBN 13: 9783540175926
Antico o usato paperback

Da: HPB-Red, Dallas, TX, U.S.A.

Valutazione del venditore 5 su 5 stelle 5 stelle, Maggiori informazioni sulle valutazioni dei venditori

paperback. Condizione: Good. Connecting readers with great books since 1972! Used textbooks may not include companion materials such as access codes, etc. May have some wear or writing/highlighting. We ship orders daily and Customer Service is our top priority! Codice articolo S_357092889

Contatta il venditore

Compra usato

EUR 8,45
Convertire valuta
Spese di spedizione: EUR 92,23
Da: U.S.A. a: Italia
Destinazione, tempi e costi

Quantità: 1 disponibili

Aggiungi al carrello

Immagini fornite dal venditore

David G. Robinson|Ulrich Ehlers|Rainer Herken|Bernd Herrmann|Frank Mayer|Friedrich-Wilhelm Schürmann
ISBN 10: 354017592X ISBN 13: 9783540175926
Nuovo Brossura

Da: moluna, Greven, Germania

Valutazione del venditore 5 su 5 stelle 5 stelle, Maggiori informazioni sulle valutazioni dei venditori

Condizione: New. Codice articolo 4883479

Contatta il venditore

Compra nuovo

EUR 92,27
Convertire valuta
Spese di spedizione: EUR 9,70
Da: Germania a: Italia
Destinazione, tempi e costi

Quantità: Più di 20 disponibili

Aggiungi al carrello

Immagini fornite dal venditore

David G. Robinson
ISBN 10: 354017592X ISBN 13: 9783540175926
Nuovo Taschenbuch
Print on Demand

Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germania

Valutazione del venditore 5 su 5 stelle 5 stelle, Maggiori informazioni sulle valutazioni dei venditori

Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -In 1939, when the electron optics laboratory of Siemens & Halske Inc. began to manufacture the first electron microscopes, the biological and medical profes sions had an unexpected instrument at their disposal which exceeded the reso lution of the light microscope by more than a hundredfold. The immediate and broad application of this new tool was complicated by the overwhelming prob lems inherent in specimen preparation for the investigation of cellular struc tures. The microtechniques applied in light microscopy were no longer appli cable, since even the thinnest paraffin layers could not be penetrated by electrons. Many competent biological and medical research workers expressed their anxiety that objects in high vacuum would be modified due to complete dehydration and the absorbed electron energy would eventually cause degrada tion to rudimentary carbon backbones. It also seemed questionable as to whether it would be possible to prepare thin sections of approximately 0. 5 11m from heterogeneous biological specimens. Thus one was suddenly in posses sion of a completely unique instrument which, when compared with the light microscope, allowed a 10-100-fold higher resolution, yet a suitable preparation methodology was lacking. This sceptical attitude towards the application of electron microscopy in bi ology and medicine was supported simultaneously by the general opinion of colloid chemists, who postulated that in the submicroscopic region of living structures no stable building blocks existed which could be revealed with this apparatus. 212 pp. Englisch. Codice articolo 9783540175926

Contatta il venditore

Compra nuovo

EUR 106,99
Convertire valuta
Spese di spedizione: EUR 11,00
Da: Germania a: Italia
Destinazione, tempi e costi

Quantità: 2 disponibili

Aggiungi al carrello

Immagini fornite dal venditore

David G. Robinson
ISBN 10: 354017592X ISBN 13: 9783540175926
Nuovo Taschenbuch

Da: AHA-BUCH GmbH, Einbeck, Germania

Valutazione del venditore 5 su 5 stelle 5 stelle, Maggiori informazioni sulle valutazioni dei venditori

Taschenbuch. Condizione: Neu. Druck auf Anfrage Neuware - Printed after ordering - In 1939, when the electron optics laboratory of Siemens & Halske Inc. began to manufacture the first electron microscopes, the biological and medical profes sions had an unexpected instrument at their disposal which exceeded the reso lution of the light microscope by more than a hundredfold. The immediate and broad application of this new tool was complicated by the overwhelming prob lems inherent in specimen preparation for the investigation of cellular struc tures. The microtechniques applied in light microscopy were no longer appli cable, since even the thinnest paraffin layers could not be penetrated by electrons. Many competent biological and medical research workers expressed their anxiety that objects in high vacuum would be modified due to complete dehydration and the absorbed electron energy would eventually cause degrada tion to rudimentary carbon backbones. It also seemed questionable as to whether it would be possible to prepare thin sections of approximately 0. 5 11m from heterogeneous biological specimens. Thus one was suddenly in posses sion of a completely unique instrument which, when compared with the light microscope, allowed a 10-100-fold higher resolution, yet a suitable preparation methodology was lacking. This sceptical attitude towards the application of electron microscopy in bi ology and medicine was supported simultaneously by the general opinion of colloid chemists, who postulated that in the submicroscopic region of living structures no stable building blocks existed which could be revealed with this apparatus. Codice articolo 9783540175926

Contatta il venditore

Compra nuovo

EUR 106,99
Convertire valuta
Spese di spedizione: EUR 14,99
Da: Germania a: Italia
Destinazione, tempi e costi

Quantità: 1 disponibili

Aggiungi al carrello

Immagini fornite dal venditore

David G. Robinson
ISBN 10: 354017592X ISBN 13: 9783540175926
Nuovo Taschenbuch

Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germania

Valutazione del venditore 5 su 5 stelle 5 stelle, Maggiori informazioni sulle valutazioni dei venditori

Taschenbuch. Condizione: Neu. Neuware -In 1939, when the electron optics laboratory of Siemens & Halske Inc. began to manufacture the first electron microscopes, the biological and medical profes sions had an unexpected instrument at their disposal which exceeded the reso lution of the light microscope by more than a hundredfold. The immediate and broad application of this new tool was complicated by the overwhelming prob lems inherent in specimen preparation for the investigation of cellular struc tures. The microtechniques applied in light microscopy were no longer appli cable, since even the thinnest paraffin layers could not be penetrated by electrons. Many competent biological and medical research workers expressed their anxiety that objects in high vacuum would be modified due to complete dehydration and the absorbed electron energy would eventually cause degrada tion to rudimentary carbon backbones. It also seemed questionable as to whether it would be possible to prepare thin sections of approximately 0. 5 11m from heterogeneous biological specimens. Thus one was suddenly in posses sion of a completely unique instrument which, when compared with the light microscope, allowed a 10-100-fold higher resolution, yet a suitable preparation methodology was lacking. This sceptical attitude towards the application of electron microscopy in bi ology and medicine was supported simultaneously by the general opinion of colloid chemists, who postulated that in the submicroscopic region of living structures no stable building blocks existed which could be revealed with this apparatus.Springer Verlag GmbH, Tiergartenstr. 17, 69121 Heidelberg 212 pp. Englisch. Codice articolo 9783540175926

Contatta il venditore

Compra nuovo

EUR 106,99
Convertire valuta
Spese di spedizione: EUR 15,00
Da: Germania a: Italia
Destinazione, tempi e costi

Quantità: 2 disponibili

Aggiungi al carrello

Foto dell'editore

Ehlers, Ulrich
Editore: Springer, 1987
ISBN 10: 354017592X ISBN 13: 9783540175926
Nuovo Brossura

Da: Ria Christie Collections, Uxbridge, Regno Unito

Valutazione del venditore 5 su 5 stelle 5 stelle, Maggiori informazioni sulle valutazioni dei venditori

Condizione: New. In. Codice articolo ria9783540175926_new

Contatta il venditore

Compra nuovo

EUR 116,02
Convertire valuta
Spese di spedizione: EUR 10,37
Da: Regno Unito a: Italia
Destinazione, tempi e costi

Quantità: Più di 20 disponibili

Aggiungi al carrello

Foto dell'editore

Ehlers, Ulrich
Editore: Springer, 1987
ISBN 10: 354017592X ISBN 13: 9783540175926
Nuovo Brossura

Da: California Books, Miami, FL, U.S.A.

Valutazione del venditore 5 su 5 stelle 5 stelle, Maggiori informazioni sulle valutazioni dei venditori

Condizione: New. Codice articolo I-9783540175926

Contatta il venditore

Compra nuovo

EUR 126,67
Convertire valuta
Spese di spedizione: EUR 7,69
Da: U.S.A. a: Italia
Destinazione, tempi e costi

Quantità: Più di 20 disponibili

Aggiungi al carrello

Foto dell'editore

David G. Robinson David G. Robinson
Editore: Springer, 1987
ISBN 10: 354017592X ISBN 13: 9783540175926
Nuovo Brossura

Da: Books Puddle, New York, NY, U.S.A.

Valutazione del venditore 4 su 5 stelle 4 stelle, Maggiori informazioni sulle valutazioni dei venditori

Condizione: New. pp. 212. Codice articolo 2658586049

Contatta il venditore

Compra nuovo

EUR 143,15
Convertire valuta
Spese di spedizione: EUR 7,69
Da: U.S.A. a: Italia
Destinazione, tempi e costi

Quantità: 4 disponibili

Aggiungi al carrello

Vedi altre 5 copie di questo libro

Vedi tutti i risultati per questo libro