Transient voltages occur on the terminals of superconducting coils and may lead to internal over-voltages. The main objective of this work was to calculate the transient electrical behaviour and internal voltage distribution within the ITER poloidal field (PF) coils at four scenarios and was made using the PF 3 and PF 6 coils as examples. The calculated maximum voltages will be used for definition of amplitudes and voltage waveforms for the tests of the high-voltage insulation of the coils.
Le informazioni nella sezione "Riassunto" possono far riferimento a edizioni diverse di questo titolo.
Da: avelibro OHG, Dinkelscherben, Germania
8° kart. Condizione: Sehr gut. 165 S. : Ill., graph. Darst. ; 24 cm, 300 g Unbenutzt und ungelesen, geringe Lagerspuren können vorhanden sein. DE-10-08 Sprache: Englisch Gewicht in Gramm: 378. Codice articolo 1835029
Quantità: 1 disponibili
Da: PBShop.store US, Wood Dale, IL, U.S.A.
PAP. Condizione: New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Codice articolo L0-9783866445956
Quantità: Più di 20 disponibili
Da: PBShop.store UK, Fairford, GLOS, Regno Unito
PAP. Condizione: New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Codice articolo L0-9783866445956
Quantità: Più di 20 disponibili
Da: Ria Christie Collections, Uxbridge, Regno Unito
Condizione: New. In English. Codice articolo ria9783866445956_new
Quantità: Più di 20 disponibili
Da: Chiron Media, Wallingford, Regno Unito
PF. Condizione: New. Codice articolo 6666-IUK-9783866445956
Quantità: 10 disponibili
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germania
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Transient voltages occur on the terminals of superconducting coils and may lead to internal over-voltages. The main objective of this work was to calculate the transient electrical behaviour and internal voltage distribution within the ITER poloidal field (PF) coils at four scenarios and was made using the PF 3 and PF 6 coils as examples. The calculated maximum voltages will be used for definition of amplitudes and voltage waveforms for the tests of the high-voltage insulation of the coils. 180 pp. Englisch. Codice articolo 9783866445956
Quantità: 2 disponibili
Da: California Books, Miami, FL, U.S.A.
Condizione: New. Codice articolo I-9783866445956
Quantità: Più di 20 disponibili
Da: moluna, Greven, Germania
Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Transient voltages occur on the terminals of superconducting coils and may lead to internal over-voltages. The main objective of this work was to calculate the transient electrical behaviour and internal voltage distribution within the ITER poloidal field (. Codice articolo 5587941
Quantità: Più di 20 disponibili
Da: Revaluation Books, Exeter, Regno Unito
Paperback. Condizione: Brand New. 180 pages. 9.29x6.61x0.39 inches. In Stock. Codice articolo x-3866445954
Quantità: 2 disponibili
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germania
Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Transient voltages occur on the terminals of superconducting coils and may lead to internal over-voltages. The main objective of this work was to calculate the transient electrical behaviour and internal voltage distribution within the ITER poloidal field (PF) coils at four scenarios and was made using the PF 3 and PF 6 coils as examples. The calculated maximum voltages will be used for definition of amplitudes and voltage waveforms for the tests of the high-voltage insulation of the coils.Books on Demand GmbH, Überseering 33, 22297 Hamburg 180 pp. Englisch. Codice articolo 9783866445956
Quantità: 1 disponibili