The present work also investigates active protection of the steel embedded in concrete that is treated with surface bonded carbon FRP. The electrically conductive carbon fiber is used as anode while the reinforcing bar is used as cathode in the present active protection. Anodic current was passed through the reinforcement in both specimens to initiate cracking in concrete. Carbon FRP sheets have been adhesively bonded to the cylinders. The adhesive has been modified to impart electrical conductivity. Specimens were exposed to highly corrosive environment for specified times. Several performance metrics have been reported and the relative efficiency of active and passive protection have been studied. The active protection technique is very effective in retarding the corrosion of steel. However, an optimum current density must be maintained to avoid damages at the interfaces of steel and concrete.
Le informazioni nella sezione "Riassunto" possono far riferimento a edizioni diverse di questo titolo.
EUR 9,70 per la spedizione da Germania a Italia
Destinazione, tempi e costiDa: moluna, Greven, Germania
Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Singh Abhishek KumarAbhishek Kumar Singh and Honey Gaur both are working in Kalinga University, Raipur as an Assistant Professor in Civil Engineering Department. Both the faculties published many International Journal Papers and had . Codice articolo 385874324
Quantità: Più di 20 disponibili
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germania
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The present work also investigates active protection of the steel embedded in concrete that is treated with surface bonded carbon FRP. The electrically conductive carbon fiber is used as anode while the reinforcing bar is used as cathode in the present active protection. Anodic current was passed through the reinforcement in both specimens to initiate cracking in concrete. Carbon FRP sheets have been adhesively bonded to the cylinders. The adhesive has been modified to impart electrical conductivity. Specimens were exposed to highly corrosive environment for specified times. Several performance metrics have been reported and the relative efficiency of active and passive protection have been studied. The active protection technique is very effective in retarding the corrosion of steel. However, an optimum current density must be maintained to avoid damages at the interfaces of steel and concrete. 128 pp. Englisch. Codice articolo 9786139851980
Quantità: 2 disponibili
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germania
Taschenbuch. Condizione: Neu. Neuware -The present work also investigates active protection of the steel embedded in concrete that is treated with surface bonded carbon FRP. The electrically conductive carbon fiber is used as anode while the reinforcing bar is used as cathode in the present active protection. Anodic current was passed through the reinforcement in both specimens to initiate cracking in concrete. Carbon FRP sheets have been adhesively bonded to the cylinders. The adhesive has been modified to impart electrical conductivity. Specimens were exposed to highly corrosive environment for specified times. Several performance metrics have been reported and the relative efficiency of active and passive protection have been studied. The active protection technique is very effective in retarding the corrosion of steel. However, an optimum current density must be maintained to avoid damages at the interfaces of steel and concrete.Books on Demand GmbH, Überseering 33, 22297 Hamburg 128 pp. Englisch. Codice articolo 9786139851980
Quantità: 2 disponibili
Da: AHA-BUCH GmbH, Einbeck, Germania
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The present work also investigates active protection of the steel embedded in concrete that is treated with surface bonded carbon FRP. The electrically conductive carbon fiber is used as anode while the reinforcing bar is used as cathode in the present active protection. Anodic current was passed through the reinforcement in both specimens to initiate cracking in concrete. Carbon FRP sheets have been adhesively bonded to the cylinders. The adhesive has been modified to impart electrical conductivity. Specimens were exposed to highly corrosive environment for specified times. Several performance metrics have been reported and the relative efficiency of active and passive protection have been studied. The active protection technique is very effective in retarding the corrosion of steel. However, an optimum current density must be maintained to avoid damages at the interfaces of steel and concrete. Codice articolo 9786139851980
Quantità: 1 disponibili