Concrete structures with non-rectangular specially shaped thin columns found out as an alternative to the above said problem and it is found out that non-rectangular specially shaped thin columns performs well structurally with all analysis results within acceptable limits. This kind of structure satisfies spatial requirements of corners as well as intersection of corners so that no visible edges or prominent column would appear in the buildings. This expands the actual usable floor area and more furniture can be placed into the buildings. For this reason, frame structure with specially shaped column is suitable blooms, especially for multi-storey buildings. This work explains the behaviour of buildings with Rectangular columns and buildings with specially shaped columns and values of various parameters like story drift, story displacement, story stiffness etc. on the basis of lateral loadsSome of the complex geometric conditions and building irregularities requires experimental and analytical approaches for different material properties and sectional properties. Such parameters cannot be directly covered by the design code books and guidelines.
Le informazioni nella sezione "Riassunto" possono far riferimento a edizioni diverse di questo titolo.
EUR 9,70 per la spedizione da Germania a Italia
Destinazione, tempi e costiDa: moluna, Greven, Germania
Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Concrete structures with non-rectangular specially shaped thin columns found out as an alternative to the above said problem and it is found out that non-rectangular specially shaped thin columns performs well structurally with all analysis results within a. Codice articolo 978655268
Quantità: Più di 20 disponibili
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germania
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Concrete structures with non-rectangular specially shaped thin columns found out as an alternative to the above said problem and it is found out that non-rectangular specially shaped thin columns performs well structurally with all analysis results within acceptable limits. This kind of structure satisfies spatial requirements of corners as well as intersection of corners so that no visible edges or prominent column would appear in the buildings. This expands the actual usable floor area and more furniture can be placed into the buildings. For this reason, frame structure with specially shaped column is suitable blooms, especially for multi-storey buildings. This work explains the behaviour of buildings with Rectangular columns and buildings with specially shaped columns and values of various parameters like story drift, story displacement, story stiffness etc. on the basis of lateral loadsSome of the complex geometric conditions and building irregularities requires experimental and analytical approaches for different material properties and sectional properties. Such parameters cannot be directly covered by the design code books and guidelines. 52 pp. Englisch. Codice articolo 9786206183822
Quantità: 2 disponibili
Da: Books Puddle, New York, NY, U.S.A.
Condizione: New. Codice articolo 26404702559
Quantità: 4 disponibili
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germania
Taschenbuch. Condizione: Neu. Neuware -Concrete structures with non-rectangular specially shaped thin columns found out as an alternative to the above said problem and it is found out that non-rectangular specially shaped thin columns performs well structurally with all analysis results within acceptable limits. This kind of structure satisfies spatial requirements of corners as well as intersection of corners so that no visible edges or prominent column would appear in the buildings. This expands the actual usable floor area and more furniture can be placed into the buildings. For this reason, frame structure with specially shaped column is suitable blooms, especially for multi-storey buildings. This work explains the behaviour of buildings with Rectangular columns and buildings with specially shaped columns and values of various parameters like story drift, story displacement, story stiffness etc. on the basis of lateral loadsSome of the complex geometric conditions and building irregularities requires experimental and analytical approaches for different material properties and sectional properties. Such parameters cannot be directly covered by the design code books and guidelines.Books on Demand GmbH, Überseering 33, 22297 Hamburg 52 pp. Englisch. Codice articolo 9786206183822
Quantità: 2 disponibili
Da: Majestic Books, Hounslow, Regno Unito
Condizione: New. Print on Demand. Codice articolo 409533056
Quantità: 4 disponibili
Da: Biblios, Frankfurt am main, HESSE, Germania
Condizione: New. PRINT ON DEMAND. Codice articolo 18404702549
Quantità: 4 disponibili
Da: AHA-BUCH GmbH, Einbeck, Germania
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Concrete structures with non-rectangular specially shaped thin columns found out as an alternative to the above said problem and it is found out that non-rectangular specially shaped thin columns performs well structurally with all analysis results within acceptable limits. This kind of structure satisfies spatial requirements of corners as well as intersection of corners so that no visible edges or prominent column would appear in the buildings. This expands the actual usable floor area and more furniture can be placed into the buildings. For this reason, frame structure with specially shaped column is suitable blooms, especially for multi-storey buildings. This work explains the behaviour of buildings with Rectangular columns and buildings with specially shaped columns and values of various parameters like story drift, story displacement, story stiffness etc. on the basis of lateral loadsSome of the complex geometric conditions and building irregularities requires experimental and analytical approaches for different material properties and sectional properties. Such parameters cannot be directly covered by the design code books and guidelines. Codice articolo 9786206183822
Quantità: 1 disponibili