In the recent past, India has seen mass destruction due to failure of structures hit earthquakes and consequently, lost a lot of lives. Hence, it is of utmost importance that attention be given to the evaluation of the adequacy of strength in RC framed structures to resist strong ground motions. In this project, a 15 year old four storey reinforced concrete structure has been considered, which lies in Seismic Zone III according to IS 1893:2002classification of seismic zones in India. For non-structural members masonry infill has been assumed. In the Equivalent Static Method of analysis, the seismic load acting on the structure is assumed to be an equivalent static horizontal force applied to individual frames. The total force applied shall be equal to the product of the acceleration response spectrum and the seismic weight. It is used only for low to high rise buildings without significant coupled lateral-torsional modes.
Le informazioni nella sezione "Riassunto" possono far riferimento a edizioni diverse di questo titolo.
Da: Books Puddle, Woodside, NY, U.S.A.
Condizione: New. Codice articolo 26400903908
Quantità: 4 disponibili
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germania
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware 72 pp. Englisch. Codice articolo 9786207455492
Quantità: 2 disponibili
Da: Majestic Books, Hounslow, Regno Unito
Condizione: New. Print on Demand. Codice articolo 395505979
Quantità: 4 disponibili
Da: Biblios, Frankfurt am main, HESSE, Germania
Condizione: New. PRINT ON DEMAND. Codice articolo 18400903918
Quantità: 4 disponibili
Da: AHA-BUCH GmbH, Einbeck, Germania
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - In the recent past, India has seen mass destruction due to failure of structures hit earthquakes and consequently, lost a lot of lives. Hence, it is of utmost importance that attention be given to the evaluation of the adequacy of strength in RC framed structures to resist strong ground motions. In this project, a 15 year old four storey reinforced concrete structure has been considered, which lies in Seismic Zone III according to IS 1893:2002classification of seismic zones in India. For non-structural members masonry infill has been assumed. In the Equivalent Static Method of analysis, the seismic load acting on the structure is assumed to be an equivalent static horizontal force applied to individual frames. The total force applied shall be equal to the product of the acceleration response spectrum and the seismic weight. It is used only for low to high rise buildings without significant coupled lateral-torsional modes. Codice articolo 9786207455492
Quantità: 1 disponibili
Da: moluna, Greven, Germania
Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Ganesh LakadeProf. Ganesh D. Lakade is Working as Asst. Prof. in Dept. of Civil Engineering at SKNSCOE, Maharashtra. He has expertise in Structural Design. He completed his BE degree in Civil Engineering from PVPIT, Sangli, Maharasht. Codice articolo 1361302056
Quantità: Più di 20 disponibili
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germania
Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -In the recent past, India has seen mass destruction due to failure of structures hit earthquakes and consequently, lost a lot of lives. Hence, it is of utmost importance that attention be given to the evaluation of the adequacy of strength in RC framed structures to resist strong ground motions. In this project, a 15 year old four storey reinforced concrete structure has been considered, which lies in Seismic Zone III according to IS 1893:2002classification of seismic zones in India. For non-structural members masonry infill has been assumed. In the Equivalent Static Method of analysis, the seismic load acting on the structure is assumed to be an equivalent static horizontal force applied to individual frames. The total force applied shall be equal to the product of the acceleration response spectrum and the seismic weight. It is used only for low to high rise buildings without significant coupled lateral-torsional modes.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 72 pp. Englisch. Codice articolo 9786207455492
Quantità: 1 disponibili
Da: preigu, Osnabrück, Germania
Taschenbuch. Condizione: Neu. RC Building Under Dynamic Forces And Suitability Of FRP Strengthening | A Performance Evaluation | Ganesh Lakade | Taschenbuch | Englisch | 2023 | LAP LAMBERT Academic Publishing | EAN 9786207455492 | Verantwortliche Person für die EU: SIA OmniScriptum Publishing, Brivibas Gatve 197, 1039 RIGA, LETTLAND, customerservice[at]vdm-vsg[dot]de | Anbieter: preigu. Codice articolo 128336322
Quantità: 5 disponibili