Accuracy Of Working Length Using Radiographic Method And Root Zx: Comparing Accuracy Of Working Length Determination Using Two Different Method-In Vivo Study. Questo articolo non è disponibile.
Lingua: inglese
Editore: Lap Lambert Academic Publishing, 2012
- Brossura
- Nuovo

Da: Revaluation Books, Exeter, Regno UnitoRevaluation Books
Venditore con 5 stelle
Venditore AbeBooks dal 6 gennaio 2003
Non disponibile
Brossura
Condizione: Nuovo
EUR 99,31
Descrizione dell’articolo da parte del venditore
60 pages. 8.66x5.91x0.14 inches. In Stock.
Codice articolo 365914102X
- Titolo
- Accuracy Of Working Length Using Radiographic Method And Root Zx: Comparing Accuracy Of Working Length Determination Using Two Different Method-In Vivo Study
- Autore
- Santosh, Ashwini; Shetty, Ashish; Meena, N.; Santosh, Ashwini; Shetty, Ashish; Meena, N.
- Editore
- Lap Lambert Academic Publishing
- Anno di pubblicazione
- 2012
- Condizione
- Brand New
- Rilegatura
- Paperback
- Lingua
- inglese
- ISBN 10
- 365914102X
- ISBN 13
- 9783659141027
- Peso dell'articolo
- 0,14 chilogrammi
The determination of an accurate working length is one of the most critical steps of endodontic therapy. The radiographic method has been the standard means of determining the working length.Number of circumstances make this less than ideal method as it is impossible to consistently detect the major and minor foramina or cemento-dentinal junction (CDJ). Electronic root canal measuring devices were developed to reduce the number of radiographs during the treatment, improve the accuracy of the root canal measurement and to save time during the procedure. Many studies have shown that the current generation of electronic devices are accurate between 82-92% when compared to radiographically determined root canal lengths. A study was done evaluate the accuracy of working length determined using conventional radiograph followed by apex locator in the same tooth and comparing these findings post extraction with the natural apical constriction, after decalcifying the tooth. A stereomicroscope and image analysis unit was used to measure the differences and the results were tabulated and analyzed.
"Riassunto" può appartenere a un’altra edizione di questo titolo.
L'autore
Dr.Ashwini.P*Sr LecturerDr.Ashish ShettyProfessorDr.N.Meena,*Professorcontributing authorsDr.Usha.H.L*PrincipalDr.Santosh.R*ProfessorDr.Ashwin.D.P*ProfessorDr.Deepak Mehta*Associate profDr.Priya*Associate prof* V.S.Dental College and HospitalBangalore, India
"Descrizione articolo" può appartenere a un’altra edizione di questo titolo.