A Comparison in the Accuracy of Mapping Nuclear Fallout Patterns Using HPAC, HYSPLIT, DELFIC FPT and an AFIT FORTRAN95 Fallout Deposition Code

Miller, April D.

ISBN 10: 124960138X ISBN 13: 9781249601388
Editore: BiblioScholar, 2012
Usato Paperback

Da Mispah books, Redhill, SURRE, Regno Unito Valutazione del venditore 4 su 5 stelle 4 stelle, Maggiori informazioni sulle valutazioni dei venditori

Venditore AbeBooks dal 15 aprile 2021

Questa copia non è più disponibile. Ecco le corrispondenze migliori per A Comparison in the Accuracy of Mapping Nuclear Fallout Patterns Using HPAC, HYSPLIT, DELFIC FPT and an AFIT FORTRAN95 Fallout Deposition Code di Miller, April D..

Riguardo questo articolo

Descrizione:

Like New. Codice articolo ERICA796124960138X6

Segnala questo articolo

Riassunto:

Four nuclear fallout mapping tools are studied to determine which tool predicts the most accurate fallout dose-rate contours with low computation time and resources. The four programs consist of the FORTRAN95 based Fallout Deposition Code (FDC), the Hazard Prediction and Assessment Capability's (HPAC) Nuclear Weapon (NWPN), the Defense Land Fallout Interpretative Code (DELFIC) Fallout Planning Tool (FPT) and the Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) Model. The models were compared to the Defense Nuclear Agency's (DNA) DNA 1251-1-EX, Compilation of Local Fallout Data from Test Detonations 1945-1962 Extracted from DASA 1251, using Warner and Platt's Measure of Effectiveness (MOE) method. In order to accurately compare models the use of the FDC and low resolution weather data was validated. HYSPLIT trials were studied varying the vertical distribution, horizontal distribution, emission rate, emission time and number of equal activity particle groups. HPAC trials were run varying the use of terrain and the terrain resolution and the DELFIC FPT trials were ran varying the length of time the ground zero winds were incorporated. The best results of each of the four nuclear mapping tools were compared with the results culminating in the determination that the DELFIC FPT is the preferred nuclear mapping tool.

Le informazioni nella sezione "Su questo libro" possono far riferimento a edizioni diverse di questo titolo.

Dati bibliografici

Titolo: A Comparison in the Accuracy of Mapping ...
Casa editrice: BiblioScholar
Data di pubblicazione: 2012
Legatura: Paperback
Condizione: Like New
Tipologia articolo: book

I migliori risultati di ricerca su AbeBooks

Vedi altre 11 copie di questo libro

Vedi tutti i risultati per questo libro