Magnetic Resonance in Food Science
Venduto da PBShop.store US, Wood Dale, IL, U.S.A.
Venditore AbeBooks dal 7 aprile 2005
Nuovi - Rilegato
Condizione: Nuovo
Spedito in U.S.A.
Quantità: 15 disponibili
Aggiungere al carrelloVenduto da PBShop.store US, Wood Dale, IL, U.S.A.
Venditore AbeBooks dal 7 aprile 2005
Condizione: Nuovo
Quantità: 15 disponibili
Aggiungere al carrelloNew Book. Shipped from UK. Established seller since 2000.
Codice articolo CX-9781849736343
There are many challenges and problems in food science and magnetic resonance methods may be used to provide answers and deepen both fundamental and practical knowledge. This book presents the latest innovations in magnetic resonance and in particular new applications to understanding the functionality of foods, their processing and stability and their impact on health, perception and behaviour. Drawing on expert knowledge from academia and industry, coverage includes structure and function, emphasizing respectively applications of spectroscopy/relaxometry and imaging/diffusometry; high resolution NMR spectroscopy as applied to quality and safety and foodomics; and, for the first time, dedicated information on perception and behaviour demonstrating the progress that has been made in applications of fMRI in this field. Providing a resource for any newcomer to the field or for those in need of a rapid update of the latest developments, this title will be an indispensable reference tool.
Data Processing and Analysis,
Evaluation of approaches for quantitative targeted profiling of complex compositions using ID 1H NMR spectroscopy D.M. Jacobs, E. van Velzen and V. Mihaleva, 3,
Alignment of ID NMR data using the iCOSHIFT tool: a tutorial F. Savorani, G. Tomasi and S.B. Engelsen, 14,
Laplace inversion for NMR data analysis Y. Song, 25,
Structure and Function, Spectroscopy/Relaxometry,
The effect of crystal size and encapsulation of salt on sodium distribution and mobility in bread as studied with 23Na double quantum filtering NMR M. Guojónsdóttir, A. Traoré and, J-P. Renou, 35,
In situ quantitative proton nuclear magnetic resonance spectroscopy analysis of milk fat fusion R. Bouteille, J. Perez, F. Khifer, D. Jouan-Rimbaud-Bouveresse, B. Lecanu and H. This, 44,
Multi-nuclear solid-state NMR as a tool to assess hydration properties of polysaccharides – regioselectively etherified celluloses Flemming H. Larsen, Michael Schöbitz and Jens Schaller, 53,
Domain sizes in triglyceride networks by 1H spin-diffusion NMR M. A. Voda, G.-J. Goudappel, R. den Adel and J. van Duynhoven, 61,
A 1H nuclear magnetic resonance (NMR) study of the changes occurring during pound cake storage E. Wilderjans, A. Luyts, I. Van Haesendonck, K. Brijs, C.M. Courtin and J.A. Delcour, 72,
Investigating depth profiles from porcine adipose tissue by HR MAS NMR spectroscopy N. Viereck, K.M. Sørensen and S.B. Engelsen, 81,
Structure and Function, Imaging/Diffusometry,
Structures in food: possibilities of imaging and diffusometry R. Bernewitz, M. Horvat, H. P. Schuchmann and G. Guthausen, 93,
Non-invasive determination of functional and structural properties of materials M.L.H. Gruwel, P. Latta and B. Tomanek, 103,
The effect of structure and imbibition mode on the rehydration kinetics of freeze-dried carrots F. Vergeldt, A. Duijster, R. van der Sman, A. Voda, S. Khalloufi, G. van Dalen, L. van Vliet, J. van Duynhoven and H. Van As, 112,
Permeability and stability of microcapsules S. Henning, D. Edelhoff, S. Leick, H. Rehage and D. Suter, 122,
MRI and bidimensional relaxometry sequences for macro and microstructure assessment in food models A. Melado-Herreros, P.Barreiro, M.E. Fernandez-Valle, T. Jimenez-Ariza, E.C. Correa, N. Campos, V. Diaz-Barcos, E.M. Rivas, M.I. Silóinz and B. Hills, 130,
Quality and Safety,
NMR approach to the study of food metabolites: practical aspects L. Mannina, A.P. Sobolev, N. Proietti, and D. Capitani, 141,
Certification of primary standards for Solid Fat Content (SFC) determination A. Bernreuther, H. Schimmel and J. van Duynhoven, 150,
Identification and semi-quantification of polysaccharides in complex food matrices by NMR E. van Velzen, N. de Roo, R. Poort, L. van Adrichem, K. Brunt, H. Schols, Y. Westphal, L. Mariani, C. Gru'n and J. van Duynhoven, 156,
High resolution-magic angle spinning NMR study of olive leaves E. Manolopoulou, A. Spinella, E. Caponetti, P. Dais, and A. Spyros, 164,
FoodOmics,
Metabolomics in a move towards personalised nutrition L. Brennan, 173,
The large scale identification and quantification of conjugates of intact and gut microbial bioconversion products of polyphenols J.J.J. van der Hooft, R.C.H. de Vos, R.J. Bino, V. Mihaleva, L. Ridder, N. de Roo, D. M. Jacobs, J. van Duynhoven, and J. Vervoort, 177,
Comprehensive analysis of coffee bean extracts by NMR spectroscopy: time course of changes in composition F. Wei, K. Furihata, T.Miyakawa, M. Koda, F. Hu and M. Tanokura, 183,
Impact of different cultivation methods on the metabolic profile of apples studied by 1H HR-MAS NMR spectroscopy M. Vermathen, M. Marzorati, D. Baumgartner, C. Good and P. Vermathen, 193,
Time domain measurements and high resolution spectroscopy are powerful Nuclear Magnetic Resonance approaches suitable to evaluate the in vitro digestion of protein-rich food products L. Laghi, E. Babini, A. Bordoni, A. Ciampa, F. Danesi, M. DiNunzio, G. Picone, V. Valli and F. Capozzi, 201,
Perception and Behaviour,
Central processing of behaviorally relevant odors in the brain of awake rats, as revealed by functional Manganese-enhanced MRI. B. Lehallier, O. Rampin, A. Saint-Albin, N. Jerome, C. Ouali, Y. Maurin, J.-M. Bonny, 215,
Appetite in the brain P.A.M. Smeets, 221,
Subject Index, 231,
EVALUATION OF APPROACHES FOR QUANTITATIVE TARGETED PROFILING OF COMPLEX COMPOSITIONS USING 1D 1H NMR SPECTROSCOPY
Doris M. Jacobs, Ewoud van Velzen, Velitchka Mihaleva
1. INTRODUCTION
Profiling of low molecular weight (LMW) compounds provides an 'unbiased' and broad view on the composition of foods and biofluids and thus is a promising approach to control the quality and safety of foods ' as well as to assess the effect of foods/nutrients in biological systems. One-dimensional (1D) 1H NMR-based profiling of LMW compounds is a common method, as it allows for simultaneously measuring a wide range of compounds with different physico-chemical properties in foods and biological fluids. It is often preferred over other analytical techniques such as LC/MS because of its speed, reproducibility and versatility despite its low sensitivity (approx > 0.1 mg/g). In addition, NMR spectroscopy delivers quantitative information by using internal or external calibrants such as chemical compounds (trimethylsilyl propionate (TSP-d6), 4,4-dimethyl-4-silapentane-1-sulfonic acid (DSS-d6) or maleic acid) or an electronic signal (ERETIC). In particular, recent advances in instrumental performance such as the PULCON (PUlse Length based CONcentration determination) method provide accurate concentrations using external calibrants. Notably, NMR spectroscopy does not require compound-specific external standards for absolute quantification, which often limits MS analysis if these standards are not commercially available.
Although quantitative NMR (qNMR) has been applied for decades mainly for structural elucidation of pure organic compounds, qNMR has only recently gained in importance for mixture analysis due to the higher resolution and sensitivity of the modern NMR instruments. Yet, the quantification of LMW compounds from 1D 1H NMR profiles nowadays still is a major hurdle because of the signal overlap preventing the accurate integration of NMR signals. This signal overlap can be reduced by acquiring two-dimensional (2D) NMR spectra, in which information is spread out to the second dimension. For example, the 2D 1H-13C heteronuclear single quantum correlation (HSQC) NMR experiments have been applied to quantify a number of metabolites in human urine. However, the data acquisition time is longer and the sensitivity of the 2D spectra is lower compared to 1D 1H NMR spectra. Alternatively, solid phase extraction (SPE) or liquid chromatography (LC) methods can be connected prior to NMR data acquisition to isolate specific compounds or compound classes. This method has mainly been applied to clean up samples, to enhance signals for better identification and quantification of compounds. Recently, SPE-NMR has also been applied to generate complementary, less complex sub-profiles from human urine samples. However, the time saving for the analysis of these sub-profiles goes at the expense of more time for sample preparation when compared to conventional NMR-based metabolite profiling of urine.
Spectral fitting of overlaid signals in 1D 1H NMR profiles is a third option and relies on fitting procedures based on certain constraints, prior knowledge, iterative procedures and convergence criteria. It is probably the most promising option, considering that fitting algorithms can in principle be applied in automation for a series of NMR profiles, in this way retaining the advantages of fast NMR data acquisition and minor sample preparation. Several software programs are currently used for spectral fitting such as AMIX (Bruker Biospin GmbH, Germany), Chenomx NMR Suite (v7.1, Chenomx, Inc Edmonton, Canada), PERCH NMR software (PERCH Solutions Ltd., Kuopio, Finland) and Mnova (MestreLab Research S.L.). Herein, we briefly demonstrate the performances of the two software packages Chenomx NMR Suite and PERCH NMR software for the quantification of compounds in food extracts and serum, respectively. Both software programs are well recognized in the field of metabolomics and quality control of natural products. Yet, they differ in fitting algorithms, automation routines, and user-friendliness. In the following we discuss the most relevant features of both software packages and indicate some limitations. We do not intend to give a detailed description of their operation procedures.
2. DISCUSSION
2.1 Quantitative Targeted Profiling Using Chenomx NMR Suite
Chenomx NMR Suite is composed of several modules. The Profiler module is used to identify and quantify compounds in the experimental spectrum. The 1H NMR spectra can be directly imported into the Profiler module or after processing using the Processor module. In the Processor module the spectra are calibrated to the signal of a Chemical Shape Indicator (TSP, DSS or Formate) to determine the concentration of individual compounds. Compounds are identified and quantified using a frequency-dependent (in this case 600-MHz) library of individual spectra, that were acquired at a temperature of 298 K using a noesypr sequence with an acquisition time of 4 s, a mixing time of 0.1 s, a water suppression delay of 0.99 s (at 58 dB), a sweep width of 12 ppm, and a relaxation delay of 1 s. The Chenomx library includes 1H NMR reference models of 302 metabolites which are managed in the Library Manager module. To quantify and identify the compounds, a Lorentzian peak shape simulation of each reference compound is superimposed upon the corresponding signals of the actual experimental spectrum. The linear combination of the selected reference components from the Chenomx library gives rise to the total spectral fit, which can be evaluated with a summation line.
The collection of I Lorentzian reference models in the Chenomx library is actually a series of quantitative reference spectra si with concentrations ci and relative response factors Florini. The determination of Florini for component i is based on the total spectral integral asi relative to the integral of the internal standard IS (as,ISi) with concentration cISi according to equation 1.
[MATHEMATICAL EXPRESSION OMITTED] (1)
Here ri is a (1 × J) row vector of J response factors of component i, ari and ar,ISi represent the integral values of the response factors of component i and internal standard IS. as,ISi and as,ISi are calculated similarly to asi and ari.
The relative response factors ([Florin]i) can be used to predict concentration levels in unknown samples provided that the same experimental conditions were applied. When standardizing against an internal standard, Florini translates the NMR signal intensities into absolute concentrations. In case the experimental conditions are not identical, Florini may be adjusted with a factor φi according to equation 2:
[MATHEMATICAL EXPRESSION OMITTED] (2)
where [??] is the integral value of the fitted component model from the Chenomx library in an unknown sample, [??] is the integral value of the fitted internal standard model in an unknown sample, εi is the residual error and φi is a constant accounting for experimental bias such as water suppression, T1 and T2 relaxation, properties of the fluid (e.g. salt concentrations, buffer strength, etc.). The linear combination of N fitted model spectra [??](1 × J) from the Chenomx library are matched with the experimental spectrum e (1 × J) by minimizing the sum of squared differences according to equation 3:
[MATHEMATICAL EXPRESSION OMITTED] (3)
Here, [??](1 × J) is a single fitted model spectrum from the Chenomx database. In the Chenomx Profiler module the least squares optimization can either be performed in an interactive or an automatic mode.
Chenomx NMR Suite has many assets, which makes this software attractive for many users. In particular, it stands out due to its user-friendliness. The user interface is programmed as 'what you see is what you get' and allows interactive fitting. Thus, this software is of interest especially for non-NMR experts. Moreover, the export functions allow for a convenient export of the concentrations to other formats for further statistical analysis.
Initially, the automatic fit routine provides estimated concentrations of all metabolites identified from the library. However, these estimated concentrations and the identification of metabolites need to be checked by visual inspection and if necessary manually adapted. Practical experience taught that most estimated concentrations need to be corrected. Usually 14 compounds can be manually fit within 2 min per spectrum. Another drawback is that Chenomx NMR Suite does not work in batch mode. Thus, the quantification of compounds in a series of NMR spectra may become a tedious endeavor.
The library comprises a large number of compounds, which is a particular asset considering that the matching of the experimental spectra with the reference spectra generally is the most convenient approach to identify compounds. The compounds in the library are metabolites from biological fluids such as urine and plasma. This implies that the library may be of limited applicability to other complex mixtures. Nevertheless, many compounds present in natural product such as vegetable extracts can still be quantified using the metabolite library. Figure 1 shows an example for a French beans extract in D2O. Even low abundant compounds such as trigonelline can be identified and quantified.
It is notable, that the library can be complemented by other compounds of interest. The Spin Simulator and Compound Builder modules are tools to create simulations and signatures of own quantitative compounds. The use of these models requires some knowledge of NMR theory. They offer a high degree of freedom, which can be useful for the quantification of polysaccharides with barely-known composition. For example, guar gum is a polysaccharide composed of a linear backbone chain of β (1-4)-linked D-mannose residues to which short 1,6-side-branches of α-D-galactose residues are linked. It is a mixture with variable length of the backbone chains and side branches. Similarly, the locust bean gum (LBG) is a high-molecular-weight hydrocolloidal polysaccharide composed of galactose and mannose units combined through (l-6)-glycosidic linkages. The complete NMR signature of these polysaccharides is only partially known. Nevertheless, reference spectra of these polysaccharide standards can be acquired, built in the Compound Builder model and subsequently incorporated into the library. These reference spectra can be used to determine their ratios in products (Figure 2).
It is notable that Chenomx NMR Suite comes with some special features that allow for certain corrections: First of all, the chemical shift position of the reference compound can be adjusted within a certain pH range (pH 4-9). This is helpful for urine analysis knowing that urine is subject to considerable variations in pH values. However, caution is demanded for reference compounds with multi-spin system: Since the chemical shift positions of the individual signals can be adjusted independently from each other, there is no control whether each signal has been shifted to the same pH value. Secondly, differences in line width between the experimental and reference spectra can be adjusted using the 'shim correction' function correcting some types of systematic errors in the experimental spectrum that may have occurred during acquisition.
Furthermore, it is noteworthy that the reference spectra were acquired under certain experimental conditions which may not be appropriate for the experimental spectrum. For example, differences in the irradiation strength for water suppression or relaxation delays may affect the signal intensities thus leading to deviating concentrations. Therefore, it is advisable to check the validity of equation (2) and, if necessary, to correct the relative response factor fi with φ according to the own experimental conditions. With this φ adjustment, a good agreement (slope = 0.94) and linearity (R2 = 0.99) between known concentrations of several compounds given by the initial weight and those determined by Chemomx NMR Suite was found (Figure 3). Moreover, the Profiler module is capable of determining concentrations from overlaid spectral regions by matching the total spectral fit to the line shape of the experimental spectrum. However, the adjustment of the concentrations may be subjective, especially if not all components of the overlaid regions are known.
Excerpted from Magnetic Resonance in Food Science by J. van Duynhoven, H. Van As, P.S. Belton, G.A. Webb. Copyright © 2013 The Royal Society of Chemistry. Excerpted by permission of The Royal Society of Chemistry.
All rights reserved. No part of this excerpt may be reproduced or reprinted without permission in writing from the publisher.
Excerpts are provided by Dial-A-Book Inc. solely for the personal use of visitors to this web site.
Le informazioni nella sezione "Su questo libro" possono far riferimento a edizioni diverse di questo titolo.
Visita la pagina della libreria
Returns Policy
We ask all customers to contact us for authorisation should they wish to return their order. Orders returned without authorisation may not be credited.
If you wish to return, please contact us within 14 days of receiving your order to obtain authorisation.
Returns requested beyond this time will not be authorised.
Our team will provide full instructions on how to return your order and once received our returns department will process your refund.
Please note the cost to return any...
Se sei un consumatore, puoi esercitare il tuo diritto di recesso seguendo le istruzioni riportate di seguito. Per "consumatore" si intende qualsiasi persona fisica che agisca per fini che non rientrano nel quadro della sua attività commerciale, industriale, artigianale o professionale.
Informazioni relative al diritto di recesso
Diritto di recesso
Hai il diritto di recedere dal presente contratto, senza indicarne le ragioni, entro 14 giorni.
Il periodo di recesso scade dopo 14 giorni dal giorno in cui
tu acquisisci, o un terzo designato diverso dal vettore e da te acquisisce, il possesso fisico dell'ultimo bene o l'ultimo lotto o pezzo.
Per esercitare il diritto di recesso, sei tenuto a informare Paperbackshop-US, 901 Penhorn Avenue, Unit 6, 07094, Secaucus, New Jersey, U.S.A., 44 1285 712917, della tua decisione di recedere dal presente contratto tramite una dichiarazione esplicita (ad esempio lettera inviata per posta, fax o posta elettronica). A tal fine puoi utilizzare il modulo tipo di recesso, ma non e' obbligatorio. Puoi anche compilare e inviare elettronicamente il modulo tipo di recesso o qualsiasi altra esplicita dichiarazione sul nostro sito web, dalla sezione "Ordini" nel "Mio Account". Nel caso scegliessi questa opzione, ti trasmetteremo senza indugio una conferma di ricevimento su un supporto durevole (ad esempio per posta elettronica).
Per rispettare il termine di recesso, é sufficiente inviare la comunicazione relativa all'esercizio del diritto di recesso prima della scadenza del periodo di recesso.
Effetti del recesso
Se recedi dal presente contratto, ti saranno rimborsati tutti i pagamenti che hai effettuato a nostro favore, compresi i costi di consegna (ad eccezione dei costi supplementari derivanti dalla tua eventuale scelta di un tipo di consegna diverso dal tipo meno costoso di consegna standard da noi offerto). Potremo trattenere dal rimborso le somme derivanti da una diminuzione del valore del prodotto risultante da una tua non necessaria manipolazione.
I rimborsi verranno effettuati senza indebito ritardo e in ogni caso non oltre 14 giorni dal giorno in cui siamo stati informati della tua decisione di recedere dal presente contratto.
Detti rimborsi saranno effettuati utilizzando lo stesso mezzo di pagamento da te usato per la transazione iniziale, salvo che tu non abbia espressamente convenuto altrimenti; in ogni caso, non dovrai sostenere alcun costo quale conseguenza di tale rimborso. Il rimborso può essere sospeso fino al ricevimento dei beni oppure fino all'avvenuta dimostrazione da parte tua di aver rispedito i beni, se precedente.
Ti preghiamo di rispedire i beni o di consegnarli a Paperbackshop-US, PaperbackShopUS, 801 Penhorn Avenue Unit 5, 07094, Secaucus, New Jersey, U.S.A., 44 1285 712917, senza indebiti ritardi e in ogni caso entro 14 giorni dal giorno in cui hai comunicato il tuo recesso dal presente contratto. Il termine è rispettato se rispedisci i beni prima della scadenza del periodo di 14 giorni. I costi diretti della restituzione dei beni saranno a tuo carico. Sei responsabile solo della diminuzione del valore dei beni risultante da una manipolazione del bene diversa da quella necessaria per stabilire la natura, le caratteristiche e il funzionamento dei beni.
Eccezioni al diritto di recesso
Il diritto di recesso non si applica in caso di:
Modulo di recesso tipo
(Compilare e restituire il presente modulo solo se si desidera recedere dal contratto)
Destinatario: (Paperbackshop-US, 901 Penhorn Avenue, Unit 6, 07094, Secaucus, New Jersey, U.S.A., 44 1285 712917)
Con la presente io/noi (*) notifichiamo il recesso dal mio/nostro (*) contratto di vendita dei seguenti beni/servizi (*)
Ordinato il (*) /ricevuto il (*)
Nome del/dei consumatore(i)
Indirizzo del/dei consumatore(i)
Firma del/dei consumatore(i) (solo se il presente modulo è notificato in versione cartacea)
Data
(*) Cancellare la dicitura inutile.
Books are shipped from our US or UK warehouses. Delivery estimates allow for delivery from either location.
| Quantità dell?ordine | Da 7 a 14 giorni lavorativi | Da 7 a 14 giorni lavorativi |
|---|---|---|
| Primo articolo | EUR 0.00 | EUR 0.00 |
I tempi di consegna sono stabiliti dai venditori e variano in base al corriere e al paese. Gli ordini che devono attraversare una dogana possono subire ritardi e spetta agli acquirenti pagare eventuali tariffe o dazi associati. I venditori possono contattarti in merito ad addebiti aggiuntivi dovuti a eventuali maggiorazioni dei costi di spedizione dei tuoi articoli.