Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing, 2017
ISBN 10: 3330023945 ISBN 13: 9783330023949
Da: Books Puddle, New York, NY, U.S.A.
Condizione: New.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing, 2017
ISBN 10: 3330023945 ISBN 13: 9783330023949
Da: Revaluation Books, Exeter, Regno Unito
EUR 50,38
Quantità: 1 disponibili
Aggiungi al carrelloPaperback. Condizione: Brand New. 52 pages. 8.66x5.91x0.12 inches. In Stock.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing Jan 2017, 2017
ISBN 10: 3330023945 ISBN 13: 9783330023949
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germania
EUR 28,90
Quantità: 2 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. Neuware -Plan optimization and verification in complex treatment delivery techniques such as IMRT and VMAT have been the two major subjects. Because the importance of precise treatment planning and accurate dose delivery is imperative to minimize any possible error in leaf speed, dose rate and gantry rotation. In this work, first the effectiveness of MONACO, which has EUD-based biological optimization combined with physical and radiobiological cost functions and some important parameters in VMAT plan optimization have been studied. Then, dose delivery of different VMAT plans such as Head and Neck (SIB: Simultaneously Integrated Boost), lung (SBRT: Stereotactic Body Radiation Therapy) and prostate (Hypo-fractionated intensity modulated arc therapy) with the Octavius 4D system has been evaluated using gamma index analysis.Books on Demand GmbH, Überseering 33, 22297 Hamburg 52 pp. Englisch.
Lingua: Spagnolo
Editore: Ediciones Nuestro Conocimiento, 2023
ISBN 10: 6206426610 ISBN 13: 9786206426615
Da: moluna, Greven, Germania
EUR 24,99
Quantità: Più di 20 disponibili
Aggiungi al carrelloCondizione: New.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing, 2017
ISBN 10: 3330023945 ISBN 13: 9783330023949
Da: preigu, Osnabrück, Germania
EUR 26,30
Quantità: 5 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. VMAT plans and delivery verification using MONACO TPS and Octavius 4D | Evaluation of simple to more complex VMAT Plans | Hossein Aslian (u. a.) | Taschenbuch | 52 S. | Englisch | 2017 | LAP LAMBERT Academic Publishing | EAN 9783330023949 | Verantwortliche Person für die EU: BoD - Books on Demand, In de Tarpen 42, 22848 Norderstedt, info[at]bod[dot]de | Anbieter: preigu.
Lingua: Spagnolo
Editore: Ediciones Nuestro Conocimiento Sep 2023, 2023
ISBN 10: 6206426610 ISBN 13: 9786206426615
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germania
EUR 28,90
Quantità: 2 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. Neuware -La optimización y verificación de planes en técnicas complejas de administración de tratamientos como IMRT y VMAT han sido los dos temas principales. Porque la importancia de una planificación precisa del tratamiento y una administración exacta de la dosis es imperativa para minimizar cualquier posible error en la velocidad de la hoja, la tasa de dosis y la rotación del gantry. En este trabajo, primero se ha estudiado la eficacia de MONACO, que tiene una optimización biológica basada en EUD combinada con funciones de coste físicas y radiobiológicas y algunos parámetros importantes en la optimización del plan VMAT. A continuación, se ha evaluado la administración de dosis de diferentes planes de VMAT como cabeza y cuello (SIB: Simultaneously Integrated Boost), pulmón (SBRT: Stereotactic Body Radiation Therapy) y próstata (Hypo-fractionated intensity modulated arc therapy) con el sistema Octavius 4D mediante el análisis del índice gamma.Books on Demand GmbH, Überseering 33, 22297 Hamburg 52 pp. Spanisch.
Da: moluna, Greven, Germania
EUR 24,99
Quantità: Più di 20 disponibili
Aggiungi al carrelloCondizione: New.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing, 2017
ISBN 10: 3330023945 ISBN 13: 9783330023949
Da: Mispah books, Redhill, SURRE, Regno Unito
EUR 115,45
Quantità: 1 disponibili
Aggiungi al carrellopaperback. Condizione: New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book.
Lingua: Francese
Editore: Editions Notre Savoir Sep 2023, 2023
ISBN 10: 6206426602 ISBN 13: 9786206426608
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germania
EUR 28,90
Quantità: 2 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. Neuware -L'optimisation et la vérification des plans dans les techniques de traitement complexes telles que l'IMRT et le VMAT ont été les deux sujets principaux. L'importance d'une planification précise du traitement et d'une administration exacte de la dose est impérative pour minimiser toute erreur possible dans la vitesse du vantail, le débit de dose et la rotation du portique. Dans ce travail, nous avons d'abord étudié l'efficacité de MONACO, qui a une optimisation biologique basée sur l'EUD combinée à des fonctions de coûts physiques et radiobiologiques, ainsi que certains paramètres importants dans l'optimisation du plan VMAT. Ensuite, la dose délivrée par différents plans VMAT tels que tête et cou (SIB : Simultaneously Integrated Boost), poumon (SBRT : Stereotactic Body Radiation Therapy) et prostate (Hypo-fractionated intensity modulated arc therapy) avec le système Octavius 4D a été évaluée à l'aide de l'analyse de l'indice gamma.Books on Demand GmbH, Überseering 33, 22297 Hamburg 52 pp. Französisch.
Da: preigu, Osnabrück, Germania
EUR 26,30
Quantità: 5 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. Plans VMAT et vérification des livraisons à l'aide de MONACO TPS et Octavius 4D | Évaluation de plans VMAT simples à plus complexes | Hossein Aslian (u. a.) | Taschenbuch | Französisch | 2023 | Editions Notre Savoir | EAN 9786206426608 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.
Lingua: Portoghese
Editore: Edições Nosso Conhecimento, 2023
ISBN 10: 6206426637 ISBN 13: 9786206426639
Da: moluna, Greven, Germania
EUR 24,99
Quantità: Più di 20 disponibili
Aggiungi al carrelloCondizione: New.
Lingua: Italiano
Editore: Edizioni Sapienza Sep 2023, 2023
ISBN 10: 6206426629 ISBN 13: 9786206426622
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germania
EUR 28,90
Quantità: 2 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. Neuware -L'ottimizzazione e la verifica dei piani in tecniche di trattamento complesse come IMRT e VMAT sono stati i due argomenti principali. L'importanza di una pianificazione precisa del trattamento e di un'erogazione accurata della dose è fondamentale per ridurre al minimo ogni possibile errore nella velocità della foglia, nel rateo di dose e nella rotazione del gantry. In questo lavoro, in primo luogo è stata studiata l'efficacia di MONACO, che ha un'ottimizzazione biologica basata su EUD combinata con funzioni di costo fisiche e radiobiologiche e alcuni parametri importanti nell'ottimizzazione del piano VMAT. In seguito, è stata valutata l'erogazione della dose di diversi piani di VMAT, quali testa e collo (SIB: Simultaneously Integrated Boost), polmone (SBRT: Stereotactic Body Radiation Therapy) e prostata (Hypo-fractionated intensity modulated arc therapy) con il sistema Octavius 4D, utilizzando l'analisi dell'indice gamma.Books on Demand GmbH, Überseering 33, 22297 Hamburg 52 pp. Italienisch.
Lingua: Tedesco
Editore: Verlag Unser Wissen Sep 2023, 2023
ISBN 10: 6206426599 ISBN 13: 9786206426592
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germania
EUR 28,90
Quantità: 2 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. Neuware -Die Optimierung und Überprüfung von Plänen bei komplexen Behandlungstechniken wie IMRT und VMAT sind die beiden Hauptthemen. Die Bedeutung einer präzisen Behandlungsplanung und einer exakten Dosisabgabe ist unabdingbar, um mögliche Fehler bei der Flügelgeschwindigkeit, der Dosisleistung und der Gantry-Rotation zu minimieren. In dieser Arbeit wurde zunächst die Effektivität von MONACO, einer EUD-basierten biologischen Optimierung in Kombination mit physikalischen und radiobiologischen Kostenfunktionen und einigen wichtigen Parametern bei der VMAT-Planoptimierung, untersucht. Anschließend wurde die Dosisabgabe verschiedener VMAT-Pläne wie Kopf und Hals (SIB: Simultaneously Integrated Boost), Lunge (SBRT: Stereotactic Body Radiation Therapy) und Prostata (Hypo-fraktionierte intensitätsmodulierte Lichtbogentherapie) mit dem Octavius 4D-System anhand der Gamma-Index-Analyse bewertet.Books on Demand GmbH, Überseering 33, 22297 Hamburg 52 pp. Deutsch.
Lingua: Portoghese
Editore: Edições Nosso Conhecimento Sep 2023, 2023
ISBN 10: 6206426637 ISBN 13: 9786206426639
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germania
EUR 28,90
Quantità: 2 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. Neuware -A otimização e verificação do plano em técnicas de aplicação de tratamento complexas, como a IMRT e a VMAT, têm sido os dois principais temas. A importância de um planeamento preciso do tratamento e de uma aplicação exacta da dose é imperativa para minimizar qualquer erro possível na velocidade da lâmina, na taxa de dose e na rotação da gantry. Neste trabalho, começou por se estudar a eficácia do MONACO, que tem uma otimização biológica baseada na EUD combinada com funções de custo físicas e radiobiológicas, e alguns parâmetros importantes na otimização do plano VMAT. Em seguida, foi avaliada a entrega de dose de diferentes planos VMAT, tais como Cabeça e Pescoço (SIB: Simultaneously Integrated Boost), pulmão (SBRT: Stereotactic Body Radiation Therapy) e próstata (Hypo-fractionated intensity modulated arc therapy) com o sistema Octavius 4D, utilizando a análise do índice gama.Books on Demand GmbH, Überseering 33, 22297 Hamburg 52 pp. Portugiesisch.
Lingua: Portoghese
Editore: Edições Nosso Conhecimento, 2023
ISBN 10: 6206426637 ISBN 13: 9786206426639
Da: preigu, Osnabrück, Germania
EUR 26,30
Quantità: 5 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. Planos VMAT e verificação da entrega utilizando o MONACO TPS e o Octavius 4D | Avaliação de planos VMAT simples a mais complexos | Hossein Aslian (u. a.) | Taschenbuch | Portugiesisch | 2023 | Edições Nosso Conhecimento | EAN 9786206426639 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.
Da: preigu, Osnabrück, Germania
EUR 26,30
Quantità: 5 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. Piani VMAT e verifica della consegna con MONACO TPS e Octavius 4D | Valutazione di piani VMAT da semplici a più complessi | Hossein Aslian (u. a.) | Taschenbuch | Italienisch | 2023 | Edizioni Sapienza | EAN 9786206426622 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.
Da: preigu, Osnabrück, Germania
EUR 28,90
Quantità: 5 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. VMAT-Pläne und Überprüfung der Lieferung mit MONACO TPS und Octavius 4D | Bewertung von einfachen bis hin zu komplexeren VMAT-Plänen | Hossein Aslian (u. a.) | Taschenbuch | 52 S. | Deutsch | 2023 | Verlag Unser Wissen | EAN 9786206426592 | Verantwortliche Person für die EU: BoD - Books on Demand, In de Tarpen 42, 22848 Norderstedt, info[at]bod[dot]de | Anbieter: preigu.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing, 2017
ISBN 10: 3330023945 ISBN 13: 9783330023949
Da: Majestic Books, Hounslow, Regno Unito
EUR 44,06
Quantità: 4 disponibili
Aggiungi al carrelloCondizione: New. Print on Demand.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing Jan 2017, 2017
ISBN 10: 3330023945 ISBN 13: 9783330023949
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germania
EUR 28,90
Quantità: 2 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Plan optimization and verification in complex treatment delivery techniques such as IMRT and VMAT have been the two major subjects. Because the importance of precise treatment planning and accurate dose delivery is imperative to minimize any possible error in leaf speed, dose rate and gantry rotation. In this work, first the effectiveness of MONACO, which has EUD-based biological optimization combined with physical and radiobiological cost functions and some important parameters in VMAT plan optimization have been studied. Then, dose delivery of different VMAT plans such as Head and Neck (SIB: Simultaneously Integrated Boost), lung (SBRT: Stereotactic Body Radiation Therapy) and prostate (Hypo-fractionated intensity modulated arc therapy) with the Octavius 4D system has been evaluated using gamma index analysis. 52 pp. Englisch.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing, 2017
ISBN 10: 3330023945 ISBN 13: 9783330023949
Da: Biblios, Frankfurt am main, HESSE, Germania
EUR 46,21
Quantità: 4 disponibili
Aggiungi al carrelloCondizione: New. PRINT ON DEMAND.
Lingua: Spagnolo
Editore: Ediciones Nuestro Conocimiento Sep 2023, 2023
ISBN 10: 6206426610 ISBN 13: 9786206426615
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germania
EUR 28,90
Quantità: 2 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -La optimización y verificación de planes en técnicas complejas de administración de tratamientos como IMRT y VMAT han sido los dos temas principales. Porque la importancia de una planificación precisa del tratamiento y una administración exacta de la dosis es imperativa para minimizar cualquier posible error en la velocidad de la hoja, la tasa de dosis y la rotación del gantry. En este trabajo, primero se ha estudiado la eficacia de MONACO, que tiene una optimización biológica basada en EUD combinada con funciones de coste físicas y radiobiológicas y algunos parámetros importantes en la optimización del plan VMAT. A continuación, se ha evaluado la administración de dosis de diferentes planes de VMAT como cabeza y cuello (SIB: Simultaneously Integrated Boost), pulmón (SBRT: Stereotactic Body Radiation Therapy) y próstata (Hypo-fractionated intensity modulated arc therapy) con el sistema Octavius 4D mediante el análisis del índice gamma. 52 pp. Spanisch.
Lingua: Francese
Editore: Editions Notre Savoir Sep 2023, 2023
ISBN 10: 6206426602 ISBN 13: 9786206426608
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germania
EUR 28,90
Quantità: 2 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -L'optimisation et la vérification des plans dans les techniques de traitement complexes telles que l'IMRT et le VMAT ont été les deux sujets principaux. L'importance d'une planification précise du traitement et d'une administration exacte de la dose est impérative pour minimiser toute erreur possible dans la vitesse du vantail, le débit de dose et la rotation du portique. Dans ce travail, nous avons d'abord étudié l'efficacité de MONACO, qui a une optimisation biologique basée sur l'EUD combinée à des fonctions de coûts physiques et radiobiologiques, ainsi que certains paramètres importants dans l'optimisation du plan VMAT. Ensuite, la dose délivrée par différents plans VMAT tels que tête et cou (SIB : Simultaneously Integrated Boost), poumon (SBRT : Stereotactic Body Radiation Therapy) et prostate (Hypo-fractionated intensity modulated arc therapy) avec le système Octavius 4D a été évaluée à l'aide de l'analyse de l'indice gamma. 52 pp. Französisch.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing, 2017
ISBN 10: 3330023945 ISBN 13: 9783330023949
Da: moluna, Greven, Germania
EUR 26,05
Quantità: Più di 20 disponibili
Aggiungi al carrelloCondizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Aslian HosseinI got my first university degree in Biomedical Engineering.Having Graduated,I got a seat in master of medical radiation engineering in my homeland IRAN.I then pursued my education in master of advanced studies in Medica.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing, 2017
ISBN 10: 3330023945 ISBN 13: 9783330023949
Da: AHA-BUCH GmbH, Einbeck, Germania
EUR 28,90
Quantità: 1 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Plan optimization and verification in complex treatment delivery techniques such as IMRT and VMAT have been the two major subjects. Because the importance of precise treatment planning and accurate dose delivery is imperative to minimize any possible error in leaf speed, dose rate and gantry rotation. In this work, first the effectiveness of MONACO, which has EUD-based biological optimization combined with physical and radiobiological cost functions and some important parameters in VMAT plan optimization have been studied. Then, dose delivery of different VMAT plans such as Head and Neck (SIB: Simultaneously Integrated Boost), lung (SBRT: Stereotactic Body Radiation Therapy) and prostate (Hypo-fractionated intensity modulated arc therapy) with the Octavius 4D system has been evaluated using gamma index analysis.
Lingua: Tedesco
Editore: Verlag Unser Wissen Sep 2023, 2023
ISBN 10: 6206426599 ISBN 13: 9786206426592
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germania
EUR 28,90
Quantità: 2 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Die Optimierung und Überprüfung von Plänen bei komplexen Behandlungstechniken wie IMRT und VMAT sind die beiden Hauptthemen. Die Bedeutung einer präzisen Behandlungsplanung und einer exakten Dosisabgabe ist unabdingbar, um mögliche Fehler bei der Flügelgeschwindigkeit, der Dosisleistung und der Gantry-Rotation zu minimieren. In dieser Arbeit wurde zunächst die Effektivität von MONACO, einer EUD-basierten biologischen Optimierung in Kombination mit physikalischen und radiobiologischen Kostenfunktionen und einigen wichtigen Parametern bei der VMAT-Planoptimierung, untersucht. Anschließend wurde die Dosisabgabe verschiedener VMAT-Pläne wie Kopf und Hals (SIB: Simultaneously Integrated Boost), Lunge (SBRT: Stereotactic Body Radiation Therapy) und Prostata (Hypo-fraktionierte intensitätsmodulierte Lichtbogentherapie) mit dem Octavius 4D-System anhand der Gamma-Index-Analyse bewertet. 52 pp. Deutsch.
Lingua: Italiano
Editore: Edizioni Sapienza Sep 2023, 2023
ISBN 10: 6206426629 ISBN 13: 9786206426622
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germania
EUR 28,90
Quantità: 2 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -L'ottimizzazione e la verifica dei piani in tecniche di trattamento complesse come IMRT e VMAT sono stati i due argomenti principali. L'importanza di una pianificazione precisa del trattamento e di un'erogazione accurata della dose è fondamentale per ridurre al minimo ogni possibile errore nella velocità della foglia, nel rateo di dose e nella rotazione del gantry. In questo lavoro, in primo luogo è stata studiata l'efficacia di MONACO, che ha un'ottimizzazione biologica basata su EUD combinata con funzioni di costo fisiche e radiobiologiche e alcuni parametri importanti nell'ottimizzazione del piano VMAT. In seguito, è stata valutata l'erogazione della dose di diversi piani di VMAT, quali testa e collo (SIB: Simultaneously Integrated Boost), polmone (SBRT: Stereotactic Body Radiation Therapy) e prostata (Hypo-fractionated intensity modulated arc therapy) con il sistema Octavius 4D, utilizzando l'analisi dell'indice gamma. 52 pp. Italienisch.
Lingua: Portoghese
Editore: Edições Nosso Conhecimento Sep 2023, 2023
ISBN 10: 6206426637 ISBN 13: 9786206426639
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germania
EUR 28,90
Quantità: 2 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -A otimização e verificação do plano em técnicas de aplicação de tratamento complexas, como a IMRT e a VMAT, têm sido os dois principais temas. A importância de um planeamento preciso do tratamento e de uma aplicação exacta da dose é imperativa para minimizar qualquer erro possível na velocidade da lâmina, na taxa de dose e na rotação da gantry. Neste trabalho, começou por se estudar a eficácia do MONACO, que tem uma otimização biológica baseada na EUD combinada com funções de custo físicas e radiobiológicas, e alguns parâmetros importantes na otimização do plano VMAT. Em seguida, foi avaliada a entrega de dose de diferentes planos VMAT, tais como Cabeça e Pescoço (SIB: Simultaneously Integrated Boost), pulmão (SBRT: Stereotactic Body Radiation Therapy) e próstata (Hypo-fractionated intensity modulated arc therapy) com o sistema Octavius 4D, utilizando a análise do índice gama. 52 pp. Portugiesisch.
Lingua: Spagnolo
Editore: Ediciones Nuestro Conocimiento, 2023
ISBN 10: 6206426610 ISBN 13: 9786206426615
Da: AHA-BUCH GmbH, Einbeck, Germania
EUR 30,73
Quantità: 1 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - La optimización y verificación de planes en técnicas complejas de administración de tratamientos como IMRT y VMAT han sido los dos temas principales. Porque la importancia de una planificación precisa del tratamiento y una administración exacta de la dosis es imperativa para minimizar cualquier posible error en la velocidad de la hoja, la tasa de dosis y la rotación del gantry. En este trabajo, primero se ha estudiado la eficacia de MONACO, que tiene una optimización biológica basada en EUD combinada con funciones de coste físicas y radiobiológicas y algunos parámetros importantes en la optimización del plan VMAT. A continuación, se ha evaluado la administración de dosis de diferentes planes de VMAT como cabeza y cuello (SIB: Simultaneously Integrated Boost), pulmón (SBRT: Stereotactic Body Radiation Therapy) y próstata (Hypo-fractionated intensity modulated arc therapy) con el sistema Octavius 4D mediante el análisis del índice gamma.
Da: AHA-BUCH GmbH, Einbeck, Germania
EUR 30,73
Quantità: 1 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - L'optimisation et la vérification des plans dans les techniques de traitement complexes telles que l'IMRT et le VMAT ont été les deux sujets principaux. L'importance d'une planification précise du traitement et d'une administration exacte de la dose est impérative pour minimiser toute erreur possible dans la vitesse du vantail, le débit de dose et la rotation du portique. Dans ce travail, nous avons d'abord étudié l'efficacité de MONACO, qui a une optimisation biologique basée sur l'EUD combinée à des fonctions de coûts physiques et radiobiologiques, ainsi que certains paramètres importants dans l'optimisation du plan VMAT. Ensuite, la dose délivrée par différents plans VMAT tels que tête et cou (SIB : Simultaneously Integrated Boost), poumon (SBRT : Stereotactic Body Radiation Therapy) et prostate (Hypo-fractionated intensity modulated arc therapy) avec le système Octavius 4D a été évaluée à l'aide de l'analyse de l'indice gamma.
Da: moluna, Greven, Germania
EUR 24,99
Quantità: Più di 20 disponibili
Aggiungi al carrelloCondizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Aslian HosseinHo conseguito la mia prima laurea in ingegneria biomedica e, dopo la laurea, ho ottenuto un posto nel master in ingegneria delle radiazioni mediche nel mio paese d origine, l IRAN. Ho poi proseguito la mia formazione in.