Isbn: 9781528126359 - investigation of extended bulb angle sections under compression: part one, as euler columns; part two, as stiffeners attached to sheet; thesis (classic reprint) (3 risultati)

Perfeziona la tua ricerca

  • Libri (3)

  • Nuovo (3)

a

Fascia di prezzo personalizzata (EUR)

a

  • Lingua: Inglese

    Editore: Forgotten Books, 2018

    1528126351 / 9781528126359

    • Brossura

    Da: PBShop.store US, Wood Dale, IL, U.S.A.PBShop.store US

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 26,46

     Spedizione gratuita 
    Spedito in U.S.A.

    Quantità: 15 disponibili

    PAP. Condizione: New. New Book. Shipped from UK. Established seller since 2000.

  • Lingua: Inglese

    Editore: Forgotten Books, 2018

    1528126351 / 9781528126359

    • Brossura

    Da: PBShop.store UK, Fairford, GLOS, Regno UnitoPBShop.store UK

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 25,47

    EUR 3,88 spedizione 
    Spedito da Regno Unito a U.S.A.

    Quantità: 15 disponibili

    PAP. Condizione: New. New Book. Shipped from UK. Established seller since 2000.

  • Lingua: Inglese

    Editore: Forgotten Books, 2024

    1528126351 / 9781528126359

    • Brossura
    • Print on Demand

    Da: Forgotten Books, London, Regno UnitoForgotten Books

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 16,77

     Spedizione gratuita 
    Spedito da Regno Unito a U.S.A.

    Quantità: Più di 20 disponibili

    Paperback. Condizione: New. Print on Demand. This book investigates the behavior of extruded bulb angle sections when used as columns for possible local plate failure and when acting as stiffeners attached to sheet, as seen in aeronautical construction. The author established that above an effective length/radius of gyration of about 78, extruded bulb angle sections follow the Euler curve. In the short column range, the Straight Line Formula gives a more conservative value than the Johnson Parabolic Formula. From the experimental data, the proportional limit for 24ST extruded sections was found to be 17006 lbs/in2. When investigating extruded bulb angle sections used as columns for possible local plate failure, the author suggests that a value of K equal to 3 be used in the formula of Timoshenko for plate failure, when the ratio length/width is greater than four. The author offers these insights on the basis of experimental plate failures. This book is a reproduction of an important historical work, digitally reconstructed using state-of-the-art technology to preserve the original format. In rare cases, an imperfection in the original, such as a blemish or missing page, may be replicated in the book. print-on-demand item.…