9783330073364 - contingency analysis and power system security: contingency methods and application of facts devices di patel, niraj; chaudhary, raju (6 risultati)
Contingency Analysis and Power System Security: Contingency Methods and Application of FACTS Devices
- Brossura
Da: Revaluation Books, Exeter, Regno UnitoRevaluation Books
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 101,19
EUR 11,69 spedizioneSpedito da Regno Unito a U.S.A.Quantità: 1 disponibili
Paperback. Condizione: Brand New. 124 pages. 8.66x5.91x0.28 inches. In Stock.
- Altre immagini
- Brossura
Da: preigu, Osnabrück, Germaniapreigu
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 44,05
EUR 70,00 spedizioneSpedito da Germania a U.S.A.Quantità: 5 disponibili
Taschenbuch. Condizione: Neu. Contingency Analysis and Power System Security | Contingency Methods and Application of FACTS Devices | Niraj Patel (u. a.) | Taschenbuch | 124 S. | Englisch | 2017 | LAP LAMBERT Academic Publishing | EAN 9783330073364 | Verantwortliche Person für die EU: BoD - Books on Demand, In de Tarpen 42, 2284…8 Norderstedt, info[at]bod[dot]de | Anbieter: preigu.
- Altre immagini
- Brossura
- Print on Demand
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermaniaBuchWeltWeit Ludwig Meier e.K.
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 49,90
EUR 23,00 spedizioneSpedito da Germania a U.S.A.Quantità: 2 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This book presents contingency analysis of power system is to predict the line outage, generator outage and to keep the system secure and reliable. Whenever the maximum violation occurs in Power system, line and generator are outag…e elements. For the system, security can be assessed using contingency analysis. It also describes the power flow analysis of power system network using Matpower 5.0 and estimating the real and reactive power flows, power losses in the entire network and phase angle using Matpower 5.0. This book shows the example of 5 bus test system and IEEE-14 bus power system, on which N-1 contingency sensitivity factors found out by MATLAB. N-1-1 contingency sensitivity factors are found out by Power World Simulator 11.0 by making 5-bus test system in it. For the corrective actions, FACTS devices like TCSC, FC are installed on line by finding proper location by sensitivity analysis method based on real power performance index by AC load flow. After installed FACTS device, GSF and LODF sensitivity factors are compared for TCSC and FC conditions. FC can improve sensitivity factors more than the TCSC and cheaper also than TCSC, but it has higher losses than TCSC. 124 pp. Englisch.
- Altre immagini
- Brossura
- Print on Demand
Da: moluna, Greven, Germaniamoluna
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 41,71
EUR 48,99 spedizioneSpedito da Germania a U.S.A.Quantità: Più di 20 disponibili
Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Patel NirajNiraj Patel did his Masters in Electrical Engineering (Electrical Power System) from Gujarat Technological University, Ahmedabad. He did his Bachelors in Electrical Engineering from Vishwaka…rma Government Engineering Colle.
- Altre immagini
- Brossura
- Print on Demand
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germaniabuchversandmimpf2000
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 49,90
EUR 60,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -This book presents contingency analysis of power system is to predict the line outage, generator outage and to keep the system secure and reliable. Whenever the maximum violation occurs in Power system, line and generator are outage el…ements. For the system, security can be assessed using contingency analysis. It also describes the power flow analysis of power system network using Matpower 5.0 and estimating the real and reactive power flows, power losses in the entire network and phase angle using Matpower 5.0. This book shows the example of 5 bus test system and IEEE-14 bus power system, on which N-1 contingency sensitivity factors found out by MATLAB. N-1-1 contingency sensitivity factors are found out by Power World Simulator 11.0 by making 5-bus test system in it. For the corrective actions, FACTS devices like TCSC, FC are installed on line by finding proper location by sensitivity analysis method based on real power performance index by AC load flow. After installed FACTS device, GSF and LODF sensitivity factors are compared for TCSC and FC conditions. FC can improve sensitivity factors more than the TCSC and cheaper also than TCSC, but it has higher losses than TCSC.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 124 pp. Englisch.
- Altre immagini
- Brossura
- Print on Demand
Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 49,90
EUR 61,02 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibili
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This book presents contingency analysis of power system is to predict the line outage, generator outage and to keep the system secure and reliable. Whenever the maximum violation occurs in Power system, line and generator are outage ele…ments. For the system, security can be assessed using contingency analysis. It also describes the power flow analysis of power system network using Matpower 5.0 and estimating the real and reactive power flows, power losses in the entire network and phase angle using Matpower 5.0. This book shows the example of 5 bus test system and IEEE-14 bus power system, on which N-1 contingency sensitivity factors found out by MATLAB. N-1-1 contingency sensitivity factors are found out by Power World Simulator 11.0 by making 5-bus test system in it. For the corrective actions, FACTS devices like TCSC, FC are installed on line by finding proper location by sensitivity analysis method based on real power performance index by AC load flow. After installed FACTS device, GSF and LODF sensitivity factors are compared for TCSC and FC conditions. FC can improve sensitivity factors more than the TCSC and cheaper also than TCSC, but it has higher losses than TCSC.





