9783330976313 - effect of distributed generation on electric power system quality: technical and economic study di attia, abla; boghdady, ghada; mahmoud, hassan (7 risultati)

- Brossura
Da: preigu, Osnabrück, Germaniapreigu
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 48,60
EUR 70,00 spedizioneSpedito da Germania a U.S.A.Quantità: 5 disponibili
Taschenbuch. Condizione: Neu. Effect of Distributed Generation on Electric Power system Quality | Technical and Economic Study | Abla Attia (u. a.) | Taschenbuch | 128 S. | Englisch | 2017 | Noor Publishing | EAN 9783330976313 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, ma…il[at]preigu[dot]de | Anbieter: preigu.

- Brossura
Da: Revaluation Books, Exeter, , Regno UnitoRevaluation Books
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 112,18
EUR 11,59 spedizioneSpedito da Regno Unito a U.S.A.Quantità: 1 disponibili
Paperback. Condizione: Brand New. 128 pages. 8.66x5.91x0.29 inches. In Stock.

- Brossura
Da: Mispah books, Redhill, SURRE, Regno UnitoMispah books
Contatta il venditoreVenditore con 4 stelleCondizione: Nuovo
EUR 177,81
EUR 28,97 spedizioneSpedito da Regno Unito a U.S.A.Quantità: 1 disponibili
paperback. Condizione: New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book.

- Brossura
- Print on Demand
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, , GermaniaBuchWeltWeit Ludwig Meier e.K.
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 55,90
EUR 23,00 spedizioneSpedito da Germania a U.S.A.Quantità: 2 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Nowadays, distributed generation (DG) is considered as a good alternative to large centralized generation plants. This is also motivated according to the world trend of eliminating transmission and distribution costs, reducing the…greenhouse gas emissions, deferring capital costs and improving the availability and reliability of electrical networks. In this thesis, two main studies are presented: The first is the study of interruption as one of the power quality indices. The static behavior and the impact of a customer load has been discussed through simulating a part of the Egyptian unified power system. Many scenarios for customer load with and without existence of DG units for different types of faults has been presented. The second is a techno-economical study on typical isolated area, required to be reclaimed and cultivated considering the agricultural and industrial loads depends on the crops and the housing of the employees. The break-even analysis, the internal rate of return calculations and how a customer could increase the efficiency of his DG units have been carried out. These studies prove the effectiveness and benefits of adding DG units to an existing system. 128 pp. Englisch.

- Brossura
- Print on Demand
Da: moluna, Greven, , Germaniamoluna
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 46,18
EUR 48,99 spedizioneSpedito da Germania a U.S.A.Quantità: Più di 20 disponibili
Kartoniert / Broschiert. Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Attia AblaDr. Abla Attia is a Prof. of Electrical Power System Analysis. She received her Ph.D. from Ain-Shams Univ., Egypt, 1992. She published many papers and supervised many… M.SC & Ph.D theses in her field. She joined EFFAT Univ...

- Brossura
- Print on Demand
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germaniabuchversandmimpf2000
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 55,90
EUR 60,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Nowadays, distributed generation (DG) is considered as a good alternative to large centralized generation plants. This is also motivated according to the world trend of eliminating transmission and distribution costs, reducing the gree…nhouse gas emissions, deferring capital costs and improving the availability and reliability of electrical networks. In this thesis, two main studies are presented: The first is the study of interruption as one of the power quality indices. The static behavior and the impact of a customer load has been discussed through simulating a part of the Egyptian unified power system. Many scenarios for customer load with and without existence of DG units for different types of faults has been presented. The second is a techno-economical study on typical isolated area, required to be reclaimed and cultivated considering the agricultural and industrial loads depends on the crops and the housing of the employees. The break-even analysis, the internal rate of return calculations and how a customer could increase the efficiency of his DG units have been carried out. These studies prove the effectiveness and benefits of adding DG units to an existing system.Books on Demand GmbH, Überseering 33, 22297 Hamburg 128 pp. Englisch.

- Brossura
- Print on Demand
Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 55,90
EUR 61,05 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibili
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Nowadays, distributed generation (DG) is considered as a good alternative to large centralized generation plants. This is also motivated according to the world trend of eliminating transmission and distribution costs, reducing the green…house gas emissions, deferring capital costs and improving the availability and reliability of electrical networks. In this thesis, two main studies are presented: The first is the study of interruption as one of the power quality indices. The static behavior and the impact of a customer load has been discussed through simulating a part of the Egyptian unified power system. Many scenarios for customer load with and without existence of DG units for different types of faults has been presented. The second is a techno-economical study on typical isolated area, required to be reclaimed and cultivated considering the agricultural and industrial loads depends on the crops and the housing of the employees. The break-even analysis, the internal rate of return calculations and how a customer could increase the efficiency of his DG units have been carried out. These studies prove the effectiveness and benefits of adding DG units to an existing system.