ISBN: 9783639718942 - fault identification in non-linear dynamic systems (8 risultati)

Lingua: Inglese
Editore: VDM Verlag Dr. Mueller Aktiengesellschaft & Co. KG, 2014
- Brossura
Da: Books Puddle, Woodside, NY, U.S.A.Books Puddle
Contatta il venditoreVenditore con 4 stelleCondizione: Nuovo
EUR 141,85
EUR 3,55 spedizioneSpedito in U.S.A.Quantità: 4 disponibili
Condizione: New. pp. 208.

- Brossura
Da: preigu, Osnabrück, Germaniapreigu
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 359,60
EUR 70,00 spedizioneSpedito da Germania a U.S.A.Quantità: 5 disponibili
Taschenbuch. Condizione: Neu. Fault Identification in Non-linear Dynamic Systems | Yimin Zhou | Taschenbuch | 208 S. | Englisch | 2014 | Scholars' Press | EAN 9783639718942 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.…

- Brossura
- Print on Demand
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermaniaBuchWeltWeit Ludwig Meier e.K.
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 89,90
EUR 23,00 spedizioneSpedito da Germania a U.S.A.Quantità: 2 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -There has been considerable interest in fault detection and identification recently due to the increasing complexity of automation processes. A more suitable strategy of using knowledge-based techniques instead of traditional linearization techniques is used to produce a model of a non-linear system. A method to generate the training data is presented. A fuzzy relational sliding mode observer (FRSMO) and proportional integral observer (FRPIO) are proposed to estimate the magnitude of incipient faults in information-poor and non-linear systems. In the fuzzy PIO, fault size can be obtained from the error passing the PI feedback compensation. In the fuzzy SMO, the equivalent injection is used to compensate for the fault thus obtaining the fault magnitude. To reduce modelling errors, an on-line learning fault identification scheme is used to update the model and identify the fault in a periodical mode with different time intervals during the whole procedure. The performance of the proposed methods is evaluated using a cooling-coil subsystem of an air-conditioning plant to identify the typical actuator fault and flow reduction fault in a simulation environment. 208 pp. Englisch.…

- Brossura
- Print on Demand
Da: moluna, Greven, Germaniamoluna
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 72,70
EUR 48,99 spedizioneSpedito da Germania a U.S.A.Quantità: Più di 20 disponibili
Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Zhou YiminYimin Zhou, DPhil, graduated from University of Oxford, UK at 2008. Currently, she is an Associate Professor working at Shenzhen Institutes of Advanced Technology, Chinese Academy Sciences, China. Her research interest incl.…

- Brossura
- Print on Demand
Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 89,90
EUR 35,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibile
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - There has been considerable interest in fault detection and identification recently due to the increasing complexity of automation processes. A more suitable strategy of using knowledge-based techniques instead of traditional linearization techniques is used to produce a model of a non-linear system. A method to generate the training data is presented. A fuzzy relational sliding mode observer (FRSMO) and proportional integral observer (FRPIO) are proposed to estimate the magnitude of incipient faults in information-poor and non-linear systems. In the fuzzy PIO, fault size can be obtained from the error passing the PI feedback compensation. In the fuzzy SMO, the equivalent injection is used to compensate for the fault thus obtaining the fault magnitude. To reduce modelling errors, an on-line learning fault identification scheme is used to update the model and identify the fault in a periodical mode with different time intervals during the whole procedure. The performance of the proposed methods is evaluated using a cooling-coil subsystem of an air-conditioning plant to identify the typical actuator fault and flow reduction fault in a simulation environment.…

Lingua: Inglese
Editore: VDM Verlag Dr. Mueller Aktiengesellschaft & Co. KG, 2014
- Brossura
- Print on Demand
Da: Majestic Books, Hounslow, Regno UnitoMajestic Books
Contatta il venditoreVenditore con 4 stelleCondizione: Nuovo
EUR 147,75
EUR 7,75 spedizioneSpedito da Regno Unito a U.S.A.Quantità: 4 disponibili
Condizione: New. Print on Demand pp. 208 2:B&W 6 x 9 in or 229 x 152 mm Perfect Bound on Creme w/Gloss Lam.

Lingua: Inglese
Editore: VDM Verlag Dr. Mueller Aktiengesellschaft & Co. KG, 2014
- Brossura
- Print on Demand
Da: Biblios, frankfurt am main, HESSE, GermaniaBiblios
Contatta il venditoreVenditore con 4 stelleCondizione: Nuovo
EUR 148,77
EUR 9,95 spedizioneSpedito da Germania a U.S.A.Quantità: 4 disponibili
Condizione: New. PRINT ON DEMAND pp. 208.

- Brossura
- Print on Demand
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germaniabuchversandmimpf2000
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 359,60
EUR 60,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibile
Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -There has been considerable interest in fault detection and identification recently due to the increasing complexity of automation processes. A more suitable strategy of using knowledge-based techniques instead of traditional linearization techniques is used to produce a model of a non-linear system. A method to generate the training data is presented. A fuzzy relational sliding mode observer (FRSMO) and proportional integral observer (FRPIO) are proposed to estimate the magnitude of incipient faults in information-poor and non-linear systems. In the fuzzy PIO, fault size can be obtained from the error passing the PI feedback compensation. In the fuzzy SMO, the equivalent injection is used to compensate for the fault thus obtaining the fault magnitude. To reduce modelling errors, an on-line learning fault identification scheme is used to update the model and identify the fault in a periodical mode with different time intervals during the whole procedure. The performance of the proposed methods is evaluated using a cooling-coil subsystem of an air-conditioning plant to identify the typical actuator fault and flow reduction fault in a simulation environment.OmniScriptum SRL, Str. Armeneasca 28/1, office 1, 2012 Chisinau 208 pp. Englisch.…