ISBN: 9783656948896 - analytical method development and stability studies of carvedilol (7 risultati)

Perfeziona la tua ricerca

  • Libri (7)

a

Fascia di prezzo personalizzata (EUR)

a

  • Lingua: Inglese

    Editore: Grin Verlag, 2015

    3656948895 / 9783656948896

    • Brossura

    Da: California Books, Miami, FL, U.S.A.California Books

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 41,26

    EUR 2,67 spedizione 
    Spedito in U.S.A.

    Quantità: Più di 20 disponibili

    Condizione: New.

  • Lingua: Inglese

    Editore: GRIN Verlag, GRIN Verlag, 2015

    3656948895 / 9783656948896

    • Brossura

    Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 29,99

    EUR 35,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 1 disponibile

    Taschenbuch. Condizione: Neu. Druck auf Anfrage Neuware - Printed after ordering - Master's Thesis from the year 2011 in the subject Medicine - Pharmacology, grade: 8.0, , course: B.Pharm.,M.Pharm, language: English, abstract: A reverse phase high performance liquid chromatographic method (HPLC) has been developed for the method development validation of Carvedilol in bulk and pharmaceutical formulation by using YMC PACK PRO 4.6 X 150 mm (5µm Particle size). The mobile phase was Buffer: Acetonitrile: (70:30) and pH was adjusted to 2 pumped at a flow rate of 1 ml/min and the eluents were monitored at 320nm. Linearity was obtained in the concentration range of 10-90 mig/ml. The retention time of Carvedilol was found to be 3.2 minute. The method was validated for specificity, accuracy, precision, linearity, and limit of detection, limit of quantification, robustness and solubility stability. LOD and LOQ were found to be 0.001 mig/ml and 0.011mig/ml respectively. The method was statistically validated and RSD was found to be less than 2% indicating high degree of accuracy and precision of the proposed HPLC method. Stability study report revealed that the drug is susceptible for acidic, alkaline, oxidative, photolytic and UV degradation. The drug is stable to thermal degradation. More over the degradants were well separated from its API. Due to its simplicity, rapidness, high precision and accuracy, the proposed HPLC method may be used for determining Carvedilol in bulk drug samples or in pharmaceutical dosage forms.…

  • Lingua: Inglese

    Editore: Grin Verlag, 2015

    3656948895 / 9783656948896

    • Brossura

    Da: Mispah books, Redhill, SURRE, Regno UnitoMispah books

    Venditore con 4 stelle
    Contatta il venditore

    Condizione: Usato - Come nuovo

    EUR 124,79

    EUR 29,99 spedizione 
    Spedito da Regno Unito a U.S.A.

    Quantità: 1 disponibile

    paperback. Condizione: Like New. LIKE NEW. SHIPS FROM MULTIPLE LOCATIONS. book.

  • Lingua: Inglese

    Editore: GRIN Verlag Jun 2015, 2015

    3656948895 / 9783656948896

    • Brossura
    • Print on Demand

    Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermaniaBuchWeltWeit Ludwig Meier e.K.

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 29,99

    EUR 23,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 2 disponibili

    Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Master's Thesis from the year 2011 in the subject Medicine - Pharmacology, grade: 8.0, , course: B.Pharm.,M.Pharm, language: English, abstract: A reverse phase high performance liquid chromatographic method (HPLC) has been developed for the method development validation of Carvedilol in bulk and pharmaceutical formulation by using YMC PACK PRO 4.6 X 150 mm (5µm Particle size). The mobile phase was Buffer: Acetonitrile: (70:30) and pH was adjusted to 2 pumped at a flow rate of 1 ml/min and the eluents were monitored at 320nm. Linearity was obtained in the concentration range of 10-90 mig/ml. The retention time of Carvedilol was found to be 3.2 minute. The method was validated for specificity, accuracy, precision, linearity, and limit of detection, limit of quantification, robustness and solubility stability. LOD and LOQ were found to be 0.001 mig/ml and 0.011mig/ml respectively. The method was statistically validated and RSD was found to be less than 2% indicating high degree of accuracy and precision of the proposed HPLC method. Stability study report revealed that the drug is susceptible for acidic, alkaline, oxidative, photolytic and UV degradation. The drug is stable to thermal degradation. More over the degradants were well separated from its API. Due to its simplicity, rapidness, high precision and accuracy, the proposed HPLC method may be used for determining Carvedilol in bulk drug samples or in pharmaceutical dosage forms. 84 pp. Englisch.…

  • Lingua: Inglese

    Editore: Grin Verlag, 2015

    3656948895 / 9783656948896

    • Brossura
    • Print on Demand

    Da: Majestic Books, Hounslow, Regno UnitoMajestic Books

    Venditore con 4 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 75,08

    EUR 7,80 spedizione 
    Spedito da Regno Unito a U.S.A.

    Quantità: 4 disponibili

    Condizione: New. Print on Demand pp. 84.

  • Lingua: Inglese

    Editore: Grin Verlag, 2015

    3656948895 / 9783656948896

    • Brossura
    • Print on Demand

    Da: Books Puddle, Woodside, NY, U.S.A.Books Puddle

    Venditore con 4 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 79,45

    EUR 3,55 spedizione 
    Spedito in U.S.A.

    Quantità: 4 disponibili

    Condizione: New. Print on Demand pp. 84.

  • Lingua: Inglese

    Editore: Grin Verlag, 2015

    3656948895 / 9783656948896

    • Brossura
    • Print on Demand

    Da: Biblios, frankfurt am main, HESSE, GermaniaBiblios

    Venditore con 4 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 75,94

    EUR 9,95 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 4 disponibili

    Condizione: New. PRINT ON DEMAND pp. 84.