Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing, 2013
ISBN 10: 3659317438 ISBN 13: 9783659317439
Da: preigu, Osnabrück, Germania
EUR 51,00
Quantità: 5 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. Optimal Placement of Var Compensators in Transmission Networks | Using Heuristic Optimization Techniques | Reza Sirjani (u. a.) | Taschenbuch | 128 S. | Englisch | 2013 | LAP LAMBERT Academic Publishing | EAN 9783659317439 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing, 2013
ISBN 10: 3659317438 ISBN 13: 9783659317439
Da: Mispah books, Redhill, SURRE, Regno Unito
EUR 138,07
Quantità: 1 disponibili
Aggiungi al carrelloPaperback. Condizione: Like New. LIKE NEW. SHIPS FROM MULTIPLE LOCATIONS. book.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing Jan 2013, 2013
ISBN 10: 3659317438 ISBN 13: 9783659317439
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germania
EUR 59,00
Quantità: 2 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Reactive power compensation has been widely used to increase the steady state transmittable power by controlling the voltage profile along the transmission lines in power systems. A number of reactive compensation devices such as shunt capacitor, static Var compensator (SVC) and static synchronous compensator (STATCOM) have long been applied by electric power utilities for this purpose. However, the benefits of reactive power compensation depend greatly on the placement and size of the compensators. In this book, heuristic optimization techniques are employed to determine the optimal location and size of Var compensators such as shunt capacitor, SVC and STATCOM in transmission networks to enhance voltage stability and improve voltage profile by minimizing power loss and total cost. A comparative study has also been done to evaluate the effectiveness of the different Var compensators. 128 pp. Englisch.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing, 2013
ISBN 10: 3659317438 ISBN 13: 9783659317439
Da: moluna, Greven, Germania
EUR 48,50
Quantità: Più di 20 disponibili
Aggiungi al carrelloCondizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Sirjani Rezareceived his B.Sc in Electrical Engineering (Power Systems) from K.N.Toosi University of Technology,Iran in 2006 M.Sc degree from SRBIAU,Iran in 2008 and PhD from National University of Malaysia (UKM) in 2012. He is a m.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing, 2013
ISBN 10: 3659317438 ISBN 13: 9783659317439
Da: AHA-BUCH GmbH, Einbeck, Germania
EUR 59,00
Quantità: 1 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Reactive power compensation has been widely used to increase the steady state transmittable power by controlling the voltage profile along the transmission lines in power systems. A number of reactive compensation devices such as shunt capacitor, static Var compensator (SVC) and static synchronous compensator (STATCOM) have long been applied by electric power utilities for this purpose. However, the benefits of reactive power compensation depend greatly on the placement and size of the compensators. In this book, heuristic optimization techniques are employed to determine the optimal location and size of Var compensators such as shunt capacitor, SVC and STATCOM in transmission networks to enhance voltage stability and improve voltage profile by minimizing power loss and total cost. A comparative study has also been done to evaluate the effectiveness of the different Var compensators.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing Jan 2013, 2013
ISBN 10: 3659317438 ISBN 13: 9783659317439
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germania
EUR 59,00
Quantità: 1 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Reactive power compensation has been widely used to increase the steady state transmittable power by controlling the voltage profile along the transmission lines in power systems. A number of reactive compensation devices such as shunt capacitor, static Var compensator (SVC) and static synchronous compensator (STATCOM) have long been applied by electric power utilities for this purpose. However, the benefits of reactive power compensation depend greatly on the placement and size of the compensators. In this book, heuristic optimization techniques are employed to determine the optimal location and size of Var compensators such as shunt capacitor, SVC and STATCOM in transmission networks to enhance voltage stability and improve voltage profile by minimizing power loss and total cost. A comparative study has also been done to evaluate the effectiveness of the different Var compensators.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 128 pp. Englisch.