Isbn: 9783659808982 - adaptive control of shunt active power filter: interval type-2 fuzzy control and adaptive backstepping of shunt active power filter (5 risultati)

Perfeziona la tua ricerca

  • Libri (5)

  • Nuovo (5)

a

Fascia di prezzo personalizzata (EUR)

a

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing, 2015

    3659808989 / 9783659808982

    • Brossura

    Da: preigu, Osnabrück, Germaniapreigu

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 64,90

    EUR 70,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 5 disponibili

    Taschenbuch. Condizione: Neu. Adaptive Control of Shunt Active Power Filter | Interval Type-2 Fuzzy Control and Adaptive Backstepping of Shunt Active Power Filter | Ashraf Hagras | Taschenbuch | 236 S. | Englisch | 2015 | LAP LAMBERT Academic Publishing | EAN 9783659808982 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.…

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing Nov 2015, 2015

    3659808989 / 9783659808982

    • Brossura
    • Print on Demand

    Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermaniaBuchWeltWeit Ludwig Meier e.K.

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 76,90

    EUR 23,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 2 disponibili

    Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This research work proposes two new adaptive control techniques for three-phase Shunt Active Power Filter (SAPF); Interval Type-2 Fuzzy Control (IT2FC) and Adaptive Backstepping Nonlinear Control (ABNC). The proposed methods have been compared with conventional linear and nonlinear controllers such as PI and type-1 fuzzy controllers. The simulation results show that the proposed methods improve transient response and reduce THD in both line currents and voltages under the conditions of parameters uncertainties, step load change and unbalanced load currents. However, ABNC provides better current tracking and DC voltage regulation performance than IT2FC. In addition, it provides robustness of performance against step change of load and frequency variations. Moreover, due to the adaptive nature of ABNC, it is possible to work without DC voltage sensor to obtain the permissible limits of THD in line currents and voltages under the same conditions. The experimental implementation proposed new current control strategy for SAPF in the stationary a-b-c frame. This method was proven to be feasible approach for design with new version of the inverter model using Freescale DSP56F807. 236 pp. Englisch.…

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing, 2015

    3659808989 / 9783659808982

    • Brossura
    • Print on Demand

    Da: moluna, Greven, Germaniamoluna

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 61,85

    EUR 48,99 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: Più di 20 disponibili

    Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Hagras AshrafDr. Ashraf Abdalla Hagras is a lecturer in the Cyclotron Project in the Egyptian Atomic Energy Authority. He received his B. Sc. ( with honors) and M. Sc. in power electronics from Benha High Institute of Technology in 1.…

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing, 2015

    3659808989 / 9783659808982

    • Brossura
    • Print on Demand

    Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 77,82

    EUR 35,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 1 disponibile

    Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This research work proposes two new adaptive control techniques for three-phase Shunt Active Power Filter (SAPF); Interval Type-2 Fuzzy Control (IT2FC) and Adaptive Backstepping Nonlinear Control (ABNC). The proposed methods have been compared with conventional linear and nonlinear controllers such as PI and type-1 fuzzy controllers. The simulation results show that the proposed methods improve transient response and reduce THD in both line currents and voltages under the conditions of parameters uncertainties, step load change and unbalanced load currents. However, ABNC provides better current tracking and DC voltage regulation performance than IT2FC. In addition, it provides robustness of performance against step change of load and frequency variations. Moreover, due to the adaptive nature of ABNC, it is possible to work without DC voltage sensor to obtain the permissible limits of THD in line currents and voltages under the same conditions. The experimental implementation proposed new current control strategy for SAPF in the stationary a-b-c frame. This method was proven to be feasible approach for design with new version of the inverter model using Freescale DSP56F807. …

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing Nov 2015, 2015

    3659808989 / 9783659808982

    • Brossura
    • Print on Demand

    Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germaniabuchversandmimpf2000

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 76,90

    EUR 60,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 1 disponibile

    Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -This research work proposes two new adaptive control techniques for three-phase Shunt Active Power Filter (SAPF); Interval Type-2 Fuzzy Control (IT2FC) and Adaptive Backstepping Nonlinear Control (ABNC). The proposed methods have been compared with conventional linear and nonlinear controllers such as PI and type-1 fuzzy controllers. The simulation results show that the proposed methods improve transient response and reduce THD in both line currents and voltages under the conditions of parameters uncertainties, step load change and unbalanced load currents. However, ABNC provides better current tracking and DC voltage regulation performance than IT2FC. In addition, it provides robustness of performance against step change of load and frequency variations. Moreover, due to the adaptive nature of ABNC, it is possible to work without DC voltage sensor to obtain the permissible limits of THD in line currents and voltages under the same conditions. The experimental implementation proposed new current control strategy for SAPF in the stationary a-b-c frame. This method was proven to be feasible approach for design with new version of the inverter model using Freescale DSP56F807.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 236 pp. Englisch. …