9783659908019 - stability indicating rp-hplc method for combined dosage form: of nebivolol hcl and indapamide di chaki, imran; pujara, naisarg (7 risultati)

- Brossura
Da: Revaluation Books, Exeter, Regno UnitoRevaluation Books
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 103,23
EUR 11,70 spedizioneSpedito da Regno Unito a U.S.A.Quantità: 1 disponibili
Paperback. Condizione: Brand New. 136 pages. 8.66x5.91x0.31 inches. In Stock.

- Brossura
Da: preigu, Osnabrück, Germaniapreigu
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 48,70
EUR 70,00 spedizioneSpedito da Germania a U.S.A.Quantità: 5 disponibili
Taschenbuch. Condizione: Neu. Stability Indicating RP-HPLC Method For Combined Dosage Form | Of Nebivolol HCl and Indapamide | Imran Chaki (u. a.) | Taschenbuch | 136 S. | Englisch | 2016 | LAP LAMBERT Academic Publishing | EAN 9783659908019 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 4907…8 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.

- Brossura
Da: Mispah books, Redhill, SURRE, Regno UnitoMispah books
Contatta il venditoreVenditore con 4 stelleCondizione: Nuovo
EUR 180,81
EUR 29,26 spedizioneSpedito da Regno Unito a U.S.A.Quantità: 1 disponibili
paperback. Condizione: New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book.

- Brossura
- Print on Demand
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermaniaBuchWeltWeit Ludwig Meier e.K.
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 55,90
EUR 23,00 spedizioneSpedito da Germania a U.S.A.Quantità: 2 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -A simple, rapid, accurate, sensitive, precise, and isocratic RP- HPLC method was develop for analysis of Nebivolol Hydrochloride and Indapamide in combined tablet dosage form. The best separation was achieved by C-18 reversed phase… column (250 mm x 4.6 mm, 5mim particle) with 50 mM Potassium dihydrogen phosphate, pH 3.5 adjusted with ortho phosphoric acid, acetonitrile and triethylamine in ratio (30:70:2 v/v) as mobile phase. Flow rate was set 1 ml/min and detection was carried out at 254 nm. Retention time of Nebivolol Hydrochloride and Indapamide was found to be 3.407 min. and 5.470 min. respectively. The Method has been validated for the combination with parameters like linearity, accuracy and precision and rubustness. Linear response for Nebivolol Hydrochloride and Indapamide were in the range of 50-150 mig/ml and 15-45 mig/ml respectively. The Percentage recoveries obtained for Nebivolol Hydrochloride and Indapamide were found to be 99.87 ± 0.20 and 99.93 ± 0.187 respectively. The study further extended to develop stability indicating method where acid, base, oxidation and thermal degradation was performed. 136 pp. Englisch.

- Brossura
- Print on Demand
Da: moluna, Greven, Germaniamoluna
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 46,18
EUR 48,99 spedizioneSpedito da Germania a U.S.A.Quantità: Più di 20 disponibili
Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Chaki ImranImran A. Chaki, Master of Pharmacy, Pharmaceutical Quality Assurance at Gujarat Technological University. Research Associate at Quest Care in Quality Assurance Department.A simple, rapid, ac…curate, sensitive, precise, .

- Brossura
- Print on Demand
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germaniabuchversandmimpf2000
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 55,90
EUR 60,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -A simple, rapid, accurate, sensitive, precise, and isocratic RP- HPLC method was develop for analysis of Nebivolol Hydrochloride and Indapamide in combined tablet dosage form. The best separation was achieved by C-18 reversed phase col…umn (250 mm x 4.6 mm, 5¿m particle) with 50 mM Potassium dihydrogen phosphate, pH 3.5 adjusted with ortho phosphoric acid, acetonitrile and triethylamine in ratio (30:70:2 v/v) as mobile phase. Flow rate was set 1 ml/min and detection was carried out at 254 nm. Retention time of Nebivolol Hydrochloride and Indapamide was found to be 3.407 min. and 5.470 min. respectively. The Method has been validated for the combination with parameters like linearity, accuracy and precision and rubustness. Linear response for Nebivolol Hydrochloride and Indapamide were in the range of 50-150 ¿g/ml and 15-45 ¿g/ml respectively. The Percentage recoveries obtained for Nebivolol Hydrochloride and Indapamide were found to be 99.87 ± 0.20 and 99.93 ± 0.187 respectively. The study further extended to develop stability indicating method where acid, base, oxidation and thermal degradation was performed.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 136 pp. Englisch.

- Brossura
- Print on Demand
Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 55,90
EUR 61,11 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibili
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - A simple, rapid, accurate, sensitive, precise, and isocratic RP- HPLC method was develop for analysis of Nebivolol Hydrochloride and Indapamide in combined tablet dosage form. The best separation was achieved by C-18 reversed phase colu…mn (250 mm x 4.6 mm, 5mim particle) with 50 mM Potassium dihydrogen phosphate, pH 3.5 adjusted with ortho phosphoric acid, acetonitrile and triethylamine in ratio (30:70:2 v/v) as mobile phase. Flow rate was set 1 ml/min and detection was carried out at 254 nm. Retention time of Nebivolol Hydrochloride and Indapamide was found to be 3.407 min. and 5.470 min. respectively. The Method has been validated for the combination with parameters like linearity, accuracy and precision and rubustness. Linear response for Nebivolol Hydrochloride and Indapamide were in the range of 50-150 mig/ml and 15-45 mig/ml respectively. The Percentage recoveries obtained for Nebivolol Hydrochloride and Indapamide were found to be 99.87 ± 0.20 and 99.93 ± 0.187 respectively. The study further extended to develop stability indicating method where acid, base, oxidation and thermal degradation was performed.