9783838152301 - finite element simulation techniques for fluid structure interaction: applications to bio-engineering and optimization di razzaq, mudassar (5 risultati)

Lingua: Inglese
Editore: Südwestdeutscher Verlag für Hochschulschriften, 2016
- Brossura
Da: preigu, Osnabrück, Germaniapreigu
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 40,20
EUR 70,00 spedizioneSpedito da Germania a U.S.A.Quantità: 5 disponibili
Taschenbuch. Condizione: Neu. Finite element simulation techniques for fluid structure interaction | Applications to bio-engineering and optimization | Mudassar Razzaq | Taschenbuch | 152 S. | Englisch | 2016 | Südwestdeutscher Verlag für Hochschulschriften | EAN 9783838152301 | Verantwortliche Person für die EU: preigu GmbH & C…o. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.

Lingua: Inglese
Editore: Südwestdeutscher Verlag Für Hochschulschriften Mai 2016, 2016
- Brossura
- Print on Demand
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermaniaBuchWeltWeit Ludwig Meier e.K.
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 44,90
EUR 23,00 spedizioneSpedito da Germania a U.S.A.Quantità: 2 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Fluid-structure interaction physical processes are very complex, non linear in nature and can not be solved analytically. In fact experimental setups are essential to provide reliable data. However, these are generally associated w…ith enormous costs, which is why the demand for numerical simulations as development tool is increasing rapidly. In this study, an Arbitrary Lagrangian-Eulerian (ALE) formulation is employed in a fully coupled monolithic way, considering the problem as one continuum. The mathematical description and the numerical schemes are designed in such a way that more complicated constitutive relations (and more realistic for biomechanics applications) for the fluid as well as the structural part can be easily incorporated. The aim is to study the interaction of the elastic walls of the aneurysm with the geometrical shape of the implanted stent structure. This study can be seen as a basic step towards the understanding of the resulting complex flow phenomena so that in future aneurysm rupture shall be suppressed by an optimal setting for the implanted stent geometry. The optimization of fluid structure interaction problems are also investigated to set the benchmark. 152 pp. Englisch.

Lingua: Inglese
Editore: Südwestdeutscher Verlag für Hochschulschriften, 2016
- Brossura
- Print on Demand
Da: moluna, Greven, Germaniamoluna
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 37,98
EUR 48,99 spedizioneSpedito da Germania a U.S.A.Quantità: Più di 20 disponibili
Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Razzaq MudassarHe has received his doctorate degree from TU Dortmund in 2011. He is scholarship holder of DAAD for PhD studies. He was part of the projects funded by BMBF. He is working as a senior sci…entific researcher with addition.

Lingua: Inglese
Editore: Südwestdeutscher Verlag Für Hochschulschriften Mai 2016, 2016
- Brossura
- Print on Demand
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germaniabuchversandmimpf2000
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 44,90
EUR 60,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Fluid-structure interaction physical processes are very complex, non linear in nature and can not be solved analytically. In fact experimental setups are essential to provide reliable data. However, these are generally associated with…enormous costs, which is why the demand for numerical simulations as development tool is increasing rapidly. In this study, an Arbitrary Lagrangian-Eulerian (ALE) formulation is employed in a fully coupled monolithic way, considering the problem as one continuum. The mathematical description and the numerical schemes are designed in such a way that more complicated constitutive relations (and more realistic for biomechanics applications) for the fluid as well as the structural part can be easily incorporated. The aim is to study the interaction of the elastic walls of the aneurysm with the geometrical shape of the implanted stent structure. This study can be seen as a basic step towards the understanding of the resulting complex flow phenomena so that in future aneurysm rupture shall be suppressed by an optimal setting for the implanted stent geometry. The optimization of fluid structure interaction problems are also investigated to set the benchmark.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 152 pp. Englisch.

- Brossura
- Print on Demand
Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 45,52
EUR 61,22 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibili
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Fluid-structure interaction physical processes are very complex, non linear in nature and can not be solved analytically. In fact experimental setups are essential to provide reliable data. However, these are generally associated with e…normous costs, which is why the demand for numerical simulations as development tool is increasing rapidly. In this study, an Arbitrary Lagrangian-Eulerian (ALE) formulation is employed in a fully coupled monolithic way, considering the problem as one continuum. The mathematical description and the numerical schemes are designed in such a way that more complicated constitutive relations (and more realistic for biomechanics applications) for the fluid as well as the structural part can be easily incorporated. The aim is to study the interaction of the elastic walls of the aneurysm with the geometrical shape of the implanted stent structure. This study can be seen as a basic step towards the understanding of the resulting complex flow phenomena so that in future aneurysm rupture shall be suppressed by an optimal setting for the implanted stent geometry. The optimization of fluid structure interaction problems are also investigated to set the benchmark.