ISBN: 9783838345284 - system modelling for 3d whole body positron emission tomography: an approach to unified system modelling of scatter and attenuation (6 risultati)

- Brossura
Da: preigu, Osnabrück, Germaniapreigu
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 58,05
EUR 70,00 spedizioneSpedito da Germania a U.S.A.Quantità: 5 disponibili
Taschenbuch. Condizione: Neu. System Modelling For 3D Whole Body Positron Emission Tomography | An Approach To Unified System Modelling Of Scatter And Attenuation | Pawel Markiewicz (u. a.) | Taschenbuch | 192 S. | Englisch | 2010 | LAP LAMBERT Academic Publishing | EAN 9783838345284 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.…

- Brossura
Da: Mispah books, Redhill, SURRE, Regno UnitoMispah books
Contatta il venditoreVenditore con 4 stelleCondizione: Usato - Come nuovo
EUR 158,24
EUR 29,54 spedizioneSpedito da Regno Unito a U.S.A.Quantità: 1 disponibile
Paperback. Condizione: Like New. LIKE NEW. SHIPS FROM MULTIPLE LOCATIONS. book.

- Brossura
- Print on Demand
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermaniaBuchWeltWeit Ludwig Meier e.K.
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 68,00
EUR 23,00 spedizioneSpedito da Germania a U.S.A.Quantità: 2 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This book concerns the development of accurate modelling of geometric detection efficiencies, photon attenuation and scatter in 3D whole body positron emission tomography (PET). In particular, large patient studies are considered where a vast majority of emitted photon pairs from around the centre of the patient is scattered and therefore attenuated from the original (true) photon trajectories. Central to this work is modelling of the scatter component by the means of a scatter transfer matrix. The matrix describes the detection of scatter events in every line of response (LOR) in terms of absolute probabilities for every individual voxel. However, to utilise the full potential of the scatter model, the true component modelling is also based on the calculation of absolute photon detection probabilities, thus allowing unification of photon scatter and attenuation. 192 pp. Englisch.…

- Brossura
- Print on Demand
Da: moluna, Greven, Germaniamoluna
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 55,21
EUR 48,99 spedizioneSpedito da Germania a U.S.A.Quantità: Più di 20 disponibili
Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Markiewicz PawelPawel Markiewicz is a postdoctoral research associate in PET imaging, based in Wolfson Molecular Imaging Centre, University of Manchester, UK. Dr Andrew Reader is a Canada Research Chair in PET imaging, based at th.…

- Brossura
- Print on Demand
Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 75,50
EUR 35,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibile
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This book concerns the development of accurate modelling of geometric detection efficiencies, photon attenuation and scatter in 3D whole body positron emission tomography (PET). In particular, large patient studies are considered where a vast majority of emitted photon pairs from around the centre of the patient is scattered and therefore attenuated from the original (true) photon trajectories. Central to this work is modelling of the scatter component by the means of a scatter transfer matrix. The matrix describes the detection of scatter events in every line of response (LOR) in terms of absolute probabilities for every individual voxel. However, to utilise the full potential of the scatter model, the true component modelling is also based on the calculation of absolute photon detection probabilities, thus allowing unification of photon scatter and attenuation.…

- Brossura
- Print on Demand
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germaniabuchversandmimpf2000
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 68,00
EUR 60,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibile
Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -This book concerns the development of accurate modelling of geometric detection efficiencies, photon attenuation and scatter in 3D whole body positron emission tomography (PET). In particular, large patient studies are considered where a vast majority of emitted photon pairs from around the centre of the patient is scattered and therefore attenuated from the original (true) photon trajectories. Central to this work is modelling of the scatter component by the means of a scatter transfer matrix. The matrix describes the detection of scatter events in every line of response (LOR) in terms of absolute probabilities for every individual voxel. However, to utilise the full potential of the scatter model, the true component modelling is also based on the calculation of absolute photon detection probabilities, thus allowing unification of photon scatter and attenuation.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 192 pp. Englisch.…