Isbn: 9783844313055 - design study and development of a scintillation amplifier: a detail description on various parts of scintillation amplifier (5 risultati)

DESIGN STUDY AND DEVELOPMENT OF A SCINTILLATION AMPLIFIER: A detail description on various parts of Scintillation Amplifier
Islam, Mohammad Aminul, Harun-or-Rashid, A.K.M, Naser Wahed,
- Brossura
Da: Mispah books, Redhill, SURRE, Regno UnitoMispah books
Contatta il venditoreVenditore con 4 stelleCondizione: Usato - Come nuovo
EUR 170,12
EUR 29,08 spedizioneSpedito da Regno Unito a U.S.A.Quantità: 1 disponibili
Paperback. Condizione: Like New. LIKE NEW. SHIPS FROM MULTIPLE LOCATIONS. book.

- Brossura
- Print on Demand
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermaniaBuchWeltWeit Ludwig Meier e.K.
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 49,00
EUR 23,00 spedizioneSpedito da Germania a U.S.A.Quantità: 2 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -In the radiation detection system, amplifier is needed from very begging to the end. The first stage in the signal processing chain is the pre-amplifier. This pre-amplifier is usually located as close as possible to the detector to avoid noise pick-up in cables. In the next stage there is the main amplifier. Therefore, amplifier is the most important parts of the nuclear radiation detection system. In this research work a scintillation amplifier has been designed to meet the various requirements in radiation measurement. There are five basic units, which constitute the scintillation amplifier. It is also concerned with the design and construction of scintillation amplifier incorporating the source buffer, pole zero cancellation circuit, a voltage amplifier, a base line restorer circuit and an emitter buffer to give output. To supply power to these circuits a ± 12 V dc stabilized power supply has been also designed. 68 pp. Englisch.…

DESIGN STUDY AND DEVELOPMENT OF A SCINTILLATION AMPLIFIER
Mohammad Aminul Islam|A.K.M Harun-or-Rashid|A.N.M Naser Wahed
- Brossura
- Print on Demand
Da: moluna, Greven, Germaniamoluna
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 41,05
EUR 48,99 spedizioneSpedito da Germania a U.S.A.Quantità: Più di 20 disponibili
Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Islam Mohammad AminulMohammad Aminul Islam was born in Comilla one of the familiar district of Bangladesh. After completion of graduation, he was joined as a lecturer of physics in the International Islamic University Chittagong (IIU.…

- Brossura
- Print on Demand
Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 70,99
EUR 35,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibili
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - In the radiation detection system, amplifier is needed from very begging to the end. The first stage in the signal processing chain is the pre-amplifier. This pre-amplifier is usually located as close as possible to the detector to avoid noise pick-up in cables. In the next stage there is the main amplifier. Therefore, amplifier is the most important parts of the nuclear radiation detection system. In this research work a scintillation amplifier has been designed to meet the various requirements in radiation measurement. There are five basic units, which constitute the scintillation amplifier. It is also concerned with the design and construction of scintillation amplifier incorporating the source buffer, pole zero cancellation circuit, a voltage amplifier, a base line restorer circuit and an emitter buffer to give output. To supply power to these circuits a ± 12 V dc stabilized power supply has been also designed.…

- Brossura
- Print on Demand
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germaniabuchversandmimpf2000
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 49,00
EUR 60,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -In the radiation detection system, amplifier is needed from very begging to the end. The first stage in the signal processing chain is the pre-amplifier. This pre-amplifier is usually located as close as possible to the detector to avoid noise pick-up in cables. In the next stage there is the main amplifier. Therefore, amplifier is the most important parts of the nuclear radiation detection system. In this research work a scintillation amplifier has been designed to meet the various requirements in radiation measurement. There are five basic units, which constitute the scintillation amplifier. It is also concerned with the design and construction of scintillation amplifier incorporating the source buffer, pole zero cancellation circuit, a voltage amplifier, a base line restorer circuit and an emitter buffer to give output. To supply power to these circuits a ± 12 V dc stabilized power supply has been also designed.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 68 pp. Englisch.…