9783844318074 - modeling and automatic generation control of interconnected thermal unit: power system model design for market based deregulated system di sachdeva, gaurav; shankar, uma (6 risultati)

- Brossura
Da: preigu, Osnabrück, Germaniapreigu
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 43,35
EUR 70,00 spedizioneSpedito da Germania a U.S.A.Quantità: 5 disponibili
Taschenbuch. Condizione: Neu. Modeling and Automatic Generation Control of Interconnected Thermal Unit | Power System Model Design for Market Based Deregulated System | Gaurav Sachdeva (u. a.) | Taschenbuch | 104 S. | Englisch | 2011 | LAP LAMBERT Academic Publishing | EAN 9783844318074 | Verantwortliche Person für die EU: preig…u GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.

- Brossura
Da: Mispah books, Redhill, SURRE, Regno UnitoMispah books
Contatta il venditoreVenditore con 4 stelleCondizione: Usato - Come nuovo
EUR 121,45
EUR 29,19 spedizioneSpedito da Regno Unito a U.S.A.Quantità: 1 disponibili
Paperback. Condizione: Like New. LIKE NEW. SHIPS FROM MULTIPLE LOCATIONS. book.

- Brossura
- Print on Demand
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermaniaBuchWeltWeit Ludwig Meier e.K.
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 49,00
EUR 23,00 spedizioneSpedito da Germania a U.S.A.Quantità: 2 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This book deals with the automatic generation control of interconnected thermal systems with Combination of the automatic voltage control and market based deregulated system. In this Particular work thermal unit is considered with…two area concept. The primary purpose of the AGC is to balance the total system generation against system load and losses so that the desired Frequency and power interchange with neighboring system are maintained. Any mismatch between generation and demand causes the system frequency to deviate from scheduled value. Thus high frequency deviation may lead to system collapse. Further the role of automatic voltage regulator is to hold terminal voltage magnitude of synchronous generator at a specified level. The interaction between frequency deviation and voltage deviation is analyzed in this book. System performance has been evaluated at various loading disturbances and at the last market structure is considered. Availability of frequency based tariff scheme is employed. Demand can be managed by managing the tariff. 104 pp. Englisch.

- Brossura
- Print on Demand
Da: moluna, Greven, Germaniamoluna
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 41,05
EUR 48,99 spedizioneSpedito da Germania a U.S.A.Quantità: Più di 20 disponibili
Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Sachdeva GauravProf. Sachdeva has done B.Tech (Electrical) & M.Tech (Power System). Author has a vast teaching experience at various universities of Punjab.(Punjabi University, Lovely Professional Univ…ersity, Thapar University, Punj.

- Brossura
- Print on Demand
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germaniabuchversandmimpf2000
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 49,00
EUR 60,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -This book deals with the automatic generation control of interconnected thermal systems with Combination of the automatic voltage control and market based deregulated system. In this Particular work thermal unit is considered with two…area concept. The primary purpose of the AGC is to balance the total system generation against system load and losses so that the desired Frequency and power interchange with neighboring system are maintained. Any mismatch between generation and demand causes the system frequency to deviate from scheduled value. Thus high frequency deviation may lead to system collapse. Further the role of automatic voltage regulator is to hold terminal voltage magnitude of synchronous generator at a specified level. The interaction between frequency deviation and voltage deviation is analyzed in this book. System performance has been evaluated at various loading disturbances and at the last market structure is considered. Availability of frequency based tariff scheme is employed. Demand can be managed by managing the tariff.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 104 pp. Englisch.

- Brossura
- Print on Demand
Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 49,59
EUR 60,87 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibili
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This book deals with the automatic generation control of interconnected thermal systems with Combination of the automatic voltage control and market based deregulated system. In this Particular work thermal unit is considered with two a…rea concept. The primary purpose of the AGC is to balance the total system generation against system load and losses so that the desired Frequency and power interchange with neighboring system are maintained. Any mismatch between generation and demand causes the system frequency to deviate from scheduled value. Thus high frequency deviation may lead to system collapse. Further the role of automatic voltage regulator is to hold terminal voltage magnitude of synchronous generator at a specified level. The interaction between frequency deviation and voltage deviation is analyzed in this book. System performance has been evaluated at various loading disturbances and at the last market structure is considered. Availability of frequency based tariff scheme is employed. Demand can be managed by managing the tariff.