Isbn: 9783846598504 - modeling film boiling and quenching: modeling film boiling and quenching on the outer surface of a calandria tube following a critical break loca in a candu (7 risultati)

- Brossura
Da: Revaluation Books, Exeter, Regno UnitoRevaluation Books
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 101,72
EUR 11,77 spedizioneSpedito da Regno Unito a U.S.A.Quantità: 1 disponibile
Paperback. Condizione: Brand New. 116 pages. 8.66x5.91x0.27 inches. In Stock.

- Brossura
Da: preigu, Osnabrück, Germaniapreigu
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 43,40
EUR 70,00 spedizioneSpedito da Germania a U.S.A.Quantità: 5 disponibili
Taschenbuch. Condizione: Neu. Modeling Film Boiling and Quenching | Modeling Film Boiling and Quenching on the Outer Surface of a Calandria Tube Following a Critical Break LOCA in a CANDU | Jian Tao Jiang (u. a.) | Taschenbuch | 116 S. | Englisch | 2011 | LAP LAMBERT Academic Publishing | EAN 9783846598504 | Verantwortliche Person für die EU: BoD - Books on Demand, In de Tarpen 42, 22848 Norderstedt, info[at]bod[dot]de | Anbieter: preigu.…

- Brossura
Da: Mispah books, Redhill, SURRE, Regno UnitoMispah books
Contatta il venditoreVenditore con 4 stelleCondizione: Nuovo
EUR 176,95
EUR 29,42 spedizioneSpedito da Regno Unito a U.S.A.Quantità: 1 disponibile
paperback. Condizione: New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book.

- Brossura
- Print on Demand
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermaniaBuchWeltWeit Ludwig Meier e.K.
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 49,00
EUR 23,00 spedizioneSpedito da Germania a U.S.A.Quantità: 2 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -In a postulated critical break LOCA in a CANDU reactor it is possible that heatup of a pressure tube (PT) causes ballooning contact with the calandria tube (CT). Stored heat can cause dryout of the CT and establishment of pool film boiling on the outer surface. The safety concern is that if the temperature of CT experiencing film boiling gets sufficiently high then failure of the fuel channel may occur. However, quench can limit the extent and duration of film boiling as has been experimentally observed. Current estimates of quench temperatures during pool film boiling are based primarily on experimental correlations. In this dissertation a novel mechanistic model of pool film boiling on the outside of CT has been developed. The model is based in part upon characterizing the vapor film thickness under buoyancy driven natural convection flows around a tube located horizontally in a large liquid pool. A transient equation is developed which quantifies the vapor film thickness and other governing parameters. This mechanistic model can be employed in safety analysis to demarcate the conditions under which fuel channel failure will not occur in a postulated critical break LOCA. 116 pp. Englisch.…

- Brossura
- Print on Demand
Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 49,59
EUR 35,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibile
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - In a postulated critical break LOCA in a CANDU reactor it is possible that heatup of a pressure tube (PT) causes ballooning contact with the calandria tube (CT). Stored heat can cause dryout of the CT and establishment of pool film boiling on the outer surface. The safety concern is that if the temperature of CT experiencing film boiling gets sufficiently high then failure of the fuel channel may occur. However, quench can limit the extent and duration of film boiling as has been experimentally observed. Current estimates of quench temperatures during pool film boiling are based primarily on experimental correlations. In this dissertation a novel mechanistic model of pool film boiling on the outside of CT has been developed. The model is based in part upon characterizing the vapor film thickness under buoyancy driven natural convection flows around a tube located horizontally in a large liquid pool. A transient equation is developed which quantifies the vapor film thickness and other governing parameters. This mechanistic model can be employed in safety analysis to demarcate the conditions under which fuel channel failure will not occur in a postulated critical break LOCA.…

- Brossura
- Print on Demand
Da: moluna, Greven, Germaniamoluna
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 41,05
EUR 48,99 spedizioneSpedito da Germania a U.S.A.Quantità: Più di 20 disponibili
Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Jiang Jian TaoMr. Jian Tao Jiang: M.A.Sc, PMP. Worked for AMEC NSS as a safety analyst in Thermal-hydraulic Department from 2007 to 2009. Currently working at Simulator Support Section in Bruce Power.Dr. John C. Luxat: Professor at M.…

- Brossura
- Print on Demand
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germaniabuchversandmimpf2000
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 49,00
EUR 60,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibile
Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -In a postulated critical break LOCA in a CANDU reactor it is possible that heatup of a pressure tube (PT) causes ballooning contact with the calandria tube (CT). Stored heat can cause dryout of the CT and establishment of pool film boiling on the outer surface. The safety concern is that if the temperature of CT experiencing film boiling gets sufficiently high then failure of the fuel channel may occur. However, quench can limit the extent and duration of film boiling as has been experimentally observed. Current estimates of quench temperatures during pool film boiling are based primarily on experimental correlations. In this dissertation a novel mechanistic model of pool film boiling on the outside of CT has been developed. The model is based in part upon characterizing the vapor film thickness under buoyancy driven natural convection flows around a tube located horizontally in a large liquid pool. A transient equation is developed which quantifies the vapor film thickness and other governing parameters. This mechanistic model can be employed in safety analysis to demarcate the conditions under which fuel channel failure will not occur in a postulated critical break LOCA.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 116 pp. Englisch.…