Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing, 2011
ISBN 10: 384659850X ISBN 13: 9783846598504
Da: Revaluation Books, Exeter, Regno Unito
EUR 98,86
Quantità: 1 disponibili
Aggiungi al carrelloPaperback. Condizione: Brand New. 116 pages. 8.66x5.91x0.27 inches. In Stock.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing, 2011
ISBN 10: 384659850X ISBN 13: 9783846598504
Da: preigu, Osnabrück, Germania
EUR 43,30
Quantità: 5 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. Modeling Film Boiling and Quenching | Modeling Film Boiling and Quenching on the Outer Surface of a Calandria Tube Following a Critical Break LOCA in a CANDU | Jian Tao Jiang (u. a.) | Taschenbuch | 116 S. | Englisch | 2011 | LAP LAMBERT Academic Publishing | EAN 9783846598504 | Verantwortliche Person für die EU: BoD - Books on Demand, In de Tarpen 42, 22848 Norderstedt, info[at]bod[dot]de | Anbieter: preigu.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing, 2011
ISBN 10: 384659850X ISBN 13: 9783846598504
Da: Mispah books, Redhill, SURRE, Regno Unito
EUR 174,27
Quantità: 1 disponibili
Aggiungi al carrellopaperback. Condizione: New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing Nov 2011, 2011
ISBN 10: 384659850X ISBN 13: 9783846598504
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germania
EUR 49,00
Quantità: 2 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -In a postulated critical break LOCA in a CANDU reactor it is possible that heatup of a pressure tube (PT) causes ballooning contact with the calandria tube (CT). Stored heat can cause dryout of the CT and establishment of pool film boiling on the outer surface. The safety concern is that if the temperature of CT experiencing film boiling gets sufficiently high then failure of the fuel channel may occur. However, quench can limit the extent and duration of film boiling as has been experimentally observed. Current estimates of quench temperatures during pool film boiling are based primarily on experimental correlations. In this dissertation a novel mechanistic model of pool film boiling on the outside of CT has been developed. The model is based in part upon characterizing the vapor film thickness under buoyancy driven natural convection flows around a tube located horizontally in a large liquid pool. A transient equation is developed which quantifies the vapor film thickness and other governing parameters. This mechanistic model can be employed in safety analysis to demarcate the conditions under which fuel channel failure will not occur in a postulated critical break LOCA. 116 pp. Englisch.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing, 2011
ISBN 10: 384659850X ISBN 13: 9783846598504
Da: moluna, Greven, Germania
EUR 41,05
Quantità: Più di 20 disponibili
Aggiungi al carrelloCondizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Jiang Jian TaoMr. Jian Tao Jiang: M.A.Sc, PMP. Worked for AMEC NSS as a safety analyst in Thermal-hydraulic Department from 2007 to 2009. Currently working at Simulator Support Section in Bruce Power.Dr. John C. Luxat: Professor at M.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing Nov 2011, 2011
ISBN 10: 384659850X ISBN 13: 9783846598504
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germania
EUR 49,00
Quantità: 1 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -In a postulated critical break LOCA in a CANDU reactor it is possible that heatup of a pressure tube (PT) causes ballooning contact with the calandria tube (CT). Stored heat can cause dryout of the CT and establishment of pool film boiling on the outer surface. The safety concern is that if the temperature of CT experiencing film boiling gets sufficiently high then failure of the fuel channel may occur. However, quench can limit the extent and duration of film boiling as has been experimentally observed. Current estimates of quench temperatures during pool film boiling are based primarily on experimental correlations. In this dissertation a novel mechanistic model of pool film boiling on the outside of CT has been developed. The model is based in part upon characterizing the vapor film thickness under buoyancy driven natural convection flows around a tube located horizontally in a large liquid pool. A transient equation is developed which quantifies the vapor film thickness and other governing parameters. This mechanistic model can be employed in safety analysis to demarcate the conditions under which fuel channel failure will not occur in a postulated critical break LOCA.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 116 pp. Englisch.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing, 2011
ISBN 10: 384659850X ISBN 13: 9783846598504
Da: AHA-BUCH GmbH, Einbeck, Germania
EUR 49,00
Quantità: 1 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - In a postulated critical break LOCA in a CANDU reactor it is possible that heatup of a pressure tube (PT) causes ballooning contact with the calandria tube (CT). Stored heat can cause dryout of the CT and establishment of pool film boiling on the outer surface. The safety concern is that if the temperature of CT experiencing film boiling gets sufficiently high then failure of the fuel channel may occur. However, quench can limit the extent and duration of film boiling as has been experimentally observed. Current estimates of quench temperatures during pool film boiling are based primarily on experimental correlations. In this dissertation a novel mechanistic model of pool film boiling on the outside of CT has been developed. The model is based in part upon characterizing the vapor film thickness under buoyancy driven natural convection flows around a tube located horizontally in a large liquid pool. A transient equation is developed which quantifies the vapor film thickness and other governing parameters. This mechanistic model can be employed in safety analysis to demarcate the conditions under which fuel channel failure will not occur in a postulated critical break LOCA.