ISBN: 9786139448432 - detection of partial discharge sources using acoustic sensor (6 risultati)

Perfeziona la tua ricerca

  • Libri (6)

  • Nuovo (6)

a

Fascia di prezzo personalizzata (EUR)

a

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing, 2019

    6139448433 / 9786139448432

    • Brossura

    Da: preigu, Osnabrück, Germaniapreigu

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 36,35

    EUR 70,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 5 disponibili

    Taschenbuch. Condizione: Neu. Detection of Partial Discharge Sources using Acoustic Sensor | Subrata Biswas | Taschenbuch | 68 S. | Englisch | 2019 | LAP LAMBERT Academic Publishing | EAN 9786139448432 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.…

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing, 2019

    6139448433 / 9786139448432

    • Brossura

    Da: Mispah books, Redhill, SURRE, Regno UnitoMispah books

    Venditore con 4 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 145,20

    EUR 29,87 spedizione 
    Spedito da Regno Unito a U.S.A.

    Quantità: 1 disponibile

    paperback. Condizione: New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book.

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing Feb 2019, 2019

    6139448433 / 9786139448432

    • Brossura
    • Print on Demand

    Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermaniaBuchWeltWeit Ludwig Meier e.K.

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 39,90

    EUR 23,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 2 disponibili

    Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Significant Aspects of the book: In majority of the literature, multiple or more than one partial discharge sources are not considered. But, it is reported that multiple partial discharges occur at the same period of time in many PD cases. In most of the research works emphasis is not given on identification of multiple PD sources within the insulation system. In this book this gap has been bridged by identification and discrimination of multiple PD sources with reasonably good accuracy. To the best of knowledge of the author, the following are original contributions of the book: a) PD source identification has been done within the emulated real life power transformer in laboratory environment. b) Discrimination of single as well as multiple PD signals within the emulated transformer from 'Multi sensor system'. c) Development of a cross-wavelet transform (XWT) aided ensemble binary support vector machine (EB-SVM) based scheme for discrimination or localization of individual and multiple PD sources inside the emulated transformer using acoustic sensor. 68 pp. Englisch.…

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing, 2019

    6139448433 / 9786139448432

    • Brossura
    • Print on Demand

    Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 45,66

    EUR 35,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 1 disponibile

    Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Significant Aspects of the book: In majority of the literature, multiple or more than one partial discharge sources are not considered. But, it is reported that multiple partial discharges occur at the same period of time in many PD cases. In most of the research works emphasis is not given on identification of multiple PD sources within the insulation system. In this book this gap has been bridged by identification and discrimination of multiple PD sources with reasonably good accuracy. To the best of knowledge of the author, the following are original contributions of the book: a) PD source identification has been done within the emulated real life power transformer in laboratory environment. b) Discrimination of single as well as multiple PD signals within the emulated transformer from 'Multi sensor system'. c) Development of a cross-wavelet transform (XWT) aided ensemble binary support vector machine (EB-SVM) based scheme for discrimination or localization of individual and multiple PD sources inside the emulated transformer using acoustic sensor.…

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing, 2019

    6139448433 / 9786139448432

    • Brossura
    • Print on Demand

    Da: moluna, Greven, Germaniamoluna

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 34,25

    EUR 48,99 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: Più di 20 disponibili

    Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Biswas Dr. SubrataSubrata Biswas was born in Kolkata, India in 1978. He obtained his B.E. degree from Burdwan University, M.E.E and Ph. D. degree from Jadavpur University, Kolkata, India in 2002 and 2006 and 2017 respectively. Presen. …

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing Feb 2019, 2019

    6139448433 / 9786139448432

    • Brossura
    • Print on Demand

    Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germaniabuchversandmimpf2000

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 39,90

    EUR 60,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 1 disponibile

    Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Significant Aspects of the book: In majority of the literature, multiple or more than one partial discharge sources are not considered. But, it is reported that multiple partial discharges occur at the same period of time in many PD cases. In most of the research works emphasis is not given on identification of multiple PD sources within the insulation system. In this book this gap has been bridged by identification and discrimination of multiple PD sources with reasonably good accuracy. To the best of knowledge of the author, the following are original contributions of the book: a) PD source identification has been done within the emulated real life power transformer in laboratory environment. b) Discrimination of single as well as multiple PD signals within the emulated transformer from 'Multi sensor system'. c) Development of a cross-wavelet transform (XWT) aided ensemble binary support vector machine (EB-SVM) based scheme for discrimination or localization of individual and multiple PD sources inside the emulated transformer using acoustic sensor.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 68 pp. Englisch.…