Isbn: 9786200587725 - computerized data processing: -an auditory prosthesis system (6 risultati)

- Brossura
Da: preigu, Osnabrück, Germaniapreigu
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 57,20
EUR 70,00 spedizioneSpedito da Germania a U.S.A.Quantità: 5 disponibili
Taschenbuch. Condizione: Neu. Computerized Data Processing | -An Auditory Prosthesis System | V Hanuman Kumar (u. a.) | Taschenbuch | 300 S. | Englisch | 2020 | LAP LAMBERT Academic Publishing | EAN 9786200587725 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. …

- Brossura
Da: Revaluation Books, Exeter, Regno UnitoRevaluation Books
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 119,19
EUR 11,81 spedizioneSpedito da Regno Unito a U.S.A.Quantità: 1 disponibile
Paperback. Condizione: Brand New. 300 pages. 8.66x5.91x0.68 inches. In Stock.

- Brossura
- Print on Demand
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermaniaBuchWeltWeit Ludwig Meier e.K.
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 66,90
EUR 23,00 spedizioneSpedito da Germania a U.S.A.Quantità: 2 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Computer based bionic systems are used for replacement of damaged human parts such as Bionic-ear for deafness, Bionic-eye for blindness, Deep Brain stimulator for diseases of the brain, and Bionic-arm for arm prostheses. For Auditory Prosthesis(Bionic-ear), a new communication protocols were designed and implemented between heterogeneous systems named Speech data processor, Internal receiver stimulator and Clinical Programming Software (CPS). CPS is used to provide the interface between computers and data processor unit. After the surgical implantation of internal unit of auditory prosthesis on deafened brain stem, the audiologist must find out the number of active electrode contacts. The impedance of each active electrode contacts are used to fit the Threshold Level (THL) and Most Comfort levels (MCL) of hearing of the particular patient. The Fitting information with the channel numbers should be saved in the CPS-text file. The generated CPS- text file downloaded into speech data processor through CPS then the speech processor is ready to process the speech or sound information with respect to that particular patient hearing levels. 300 pp. Englisch.…

- Brossura
- Print on Demand
Da: moluna, Greven, Germaniamoluna
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 54,39
EUR 48,99 spedizioneSpedito da Germania a U.S.A.Quantità: Più di 20 disponibili
Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Kumar Dr. V HanumanDr. V. Hanuman, A Computer Science and Engineering professional with strong expertise with Data Processing and Machine Learning Algorithms, Computerized Bionics, Data Analytics and Engineering. Dr. V., graduated wi.…

- Brossura
- Print on Demand
Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 72,49
EUR 35,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibile
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Computer based bionic systems are used for replacement of damaged human parts such as Bionic-ear for deafness, Bionic-eye for blindness, Deep Brain stimulator for diseases of the brain, and Bionic-arm for arm prostheses. For Auditory Prosthesis(Bionic-ear), a new communication protocols were designed and implemented between heterogeneous systems named Speech data processor, Internal receiver stimulator and Clinical Programming Software (CPS). CPS is used to provide the interface between computers and data processor unit. After the surgical implantation of internal unit of auditory prosthesis on deafened brain stem, the audiologist must find out the number of active electrode contacts. The impedance of each active electrode contacts are used to fit the Threshold Level (THL) and Most Comfort levels (MCL) of hearing of the particular patient. The Fitting information with the channel numbers should be saved in the CPS-text file. The generated CPS- text file downloaded into speech data processor through CPS then the speech processor is ready to process the speech or sound information with respect to that particular patient hearing levels.…

- Brossura
- Print on Demand
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germaniabuchversandmimpf2000
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 66,90
EUR 60,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibile
Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Computer based bionic systems are used for replacement of damaged human parts such as Bionic-ear for deafness, Bionic-eye for blindness, Deep Brain stimulator for diseases of the brain, and Bionic-arm for arm prostheses. For Auditory Prosthesis(Bionic-ear), a new communication protocols were designed and implemented between heterogeneous systems named Speech data processor, Internal receiver stimulator and Clinical Programming Software (CPS). CPS is used to provide the interface between computers and data processor unit. After the surgical implantation of internal unit of auditory prosthesis on deafened brain stem, the audiologist must find out the number of active electrode contacts. The impedance of each active electrode contacts are used to fit the Threshold Level (THL) and Most Comfort levels (MCL) of hearing of the particular patient. The Fitting information with the channel numbers should be saved in the CPS-text file. The generated CPS- text file downloaded into speech data processor through CPS then the speech processor is ready to process the speech or sound information with respect to that particular patient hearing levels.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 300 pp. Englisch.…