ISBN: 9786202197380 - full diagnostics of an inductive plasma section of an ion thruster (5 risultati)

Full diagnostics of an inductive plasma section of an ion thruster
Riaby, Valentin/ Pavel Masherov, Vladimir Savinov,/ Yakunin, Valery
- Brossura
Da: Revaluation Books, Exeter, Regno UnitoRevaluation Books
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 55,48
EUR 11,88 spedizioneSpedito da Regno Unito a U.S.A.Quantità: 1 disponibile
Paperback. Condizione: Brand New. 112 pages. 8.66x5.91x0.26 inches. In Stock.

Full diagnostics of an inductive plasma section of an ion thruster
Valentin Riaby|Vladimir Savinov, Pavel Masherov|Valery Yakunin
- Brossura
Da: moluna, Greven, Germaniamoluna
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 26,80
EUR 48,99 spedizioneSpedito da Germania a U.S.A.Quantità: Più di 20 disponibili
Condizione: New.

- Brossura
- Print on Demand
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermaniaBuchWeltWeit Ludwig Meier e.K.
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 29,90
EUR 23,00 spedizioneSpedito da Germania a U.S.A.Quantità: 2 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Inductive low pressure xenon plasma was generated in an input section of an ion thruster. Its full diagnostics consisted of integral property measurements (Patented) and local plasma parameter determination. Accurate local diagnostics disclosed plasma parameter distributions using cylindrical Langmuir probes. Their leads were protected by conventional bare shields. Subsequent analysis showed that they distorted xenon plasma lowering all its parameters. Then probe diagnostics was specifically arranged with radially movable straight probe-1 and the additional L-shaped probe-2. They both operated in one special position: shield-1 was absent and shield-2 was non-zero disclosing measurement errors which helped to correct probe-1's data. As the result three new probe applications have been proposed: a) elimination of bare probe protective shield's influence on measurement results (Pat. Applic-n); b) measurements of the probe sheath thicknesses and the mean ion mass using cylindrical probes in Maxwellian plasmas (Patented); c) evaluation of ion current density distributions to an ion extracting electrode of an ion thruster arranged by the plane by-wall probe simulator (Pat. Applic-n). 112 pp. Englisch.…

- Brossura
- Print on Demand
Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 35,74
EUR 35,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibile
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Inductive low pressure xenon plasma was generated in an input section of an ion thruster. Its full diagnostics consisted of integral property measurements (Patented) and local plasma parameter determination. Accurate local diagnostics disclosed plasma parameter distributions using cylindrical Langmuir probes. Their leads were protected by conventional bare shields. Subsequent analysis showed that they distorted xenon plasma lowering all its parameters. Then probe diagnostics was specifically arranged with radially movable straight probe-1 and the additional L-shaped probe-2. They both operated in one special position: shield-1 was absent and shield-2 was non-zero disclosing measurement errors which helped to correct probe-1's data. As the result three new probe applications have been proposed: a) elimination of bare probe protective shield's influence on measurement results (Pat. Applic-n); b) measurements of the probe sheath thicknesses and the mean ion mass using cylindrical probes in Maxwellian plasmas (Patented); c) evaluation of ion current density distributions to an ion extracting electrode of an ion thruster arranged by the plane by-wall probe simulator (Pat. Applic-n).…

- Brossura
- Print on Demand
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germaniabuchversandmimpf2000
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 29,90
EUR 60,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibile
Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Inductive low pressure xenon plasma was generated in an input section of an ion thruster. Its full diagnostics consisted of integral property measurements (Patented) and local plasma parameter determination. Accurate local diagnostics disclosed plasma parameter distributions using cylindrical Langmuir probes. Their leads were protected by conventional bare shields. Subsequent analysis showed that they distorted xenon plasma lowering all its parameters. Then probe diagnostics was specifically arranged with radially movable straight probe-1 and the additional L-shaped probe-2. They both operated in one special position: shield-1 was absent and shield-2 was non-zero disclosing measurement errors which helped to correct probe-1's data. As the result three new probe applications have been proposed: a) elimination of bare probe protective shield's influence on measurement results (Pat. Applic-n); b) measurements of the probe sheath thicknesses and the mean ion mass using cylindrical probes in Maxwellian plasmas (Patented); c) evaluation of ion current density distributions to an ion extracting electrode of an ion thruster arranged by the plane by-wall probe simulator (Pat. Applic-n).VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 112 pp. Englisch.…