ISBN: 9786202197380 - full diagnostics of an inductive plasma section of an ion thruster (5 risultati)

Perfeziona la tua ricerca

  • Libri (5)

  • Nuovo (5)

a

Fascia di prezzo personalizzata (EUR)

a

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing, 2018

    6202197382 / 9786202197380

    • Brossura

    Da: Revaluation Books, Exeter, Regno UnitoRevaluation Books

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 55,48

    EUR 11,88 spedizione 
    Spedito da Regno Unito a U.S.A.

    Quantità: 1 disponibile

    Paperback. Condizione: Brand New. 112 pages. 8.66x5.91x0.26 inches. In Stock.

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing, 2018

    6202197382 / 9786202197380

    • Brossura

    Da: moluna, Greven, Germaniamoluna

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 26,80

    EUR 48,99 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: Più di 20 disponibili

    Condizione: New.

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing Jan 2018, 2018

    6202197382 / 9786202197380

    • Brossura
    • Print on Demand

    Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermaniaBuchWeltWeit Ludwig Meier e.K.

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 29,90

    EUR 23,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 2 disponibili

    Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Inductive low pressure xenon plasma was generated in an input section of an ion thruster. Its full diagnostics consisted of integral property measurements (Patented) and local plasma parameter determination. Accurate local diagnostics disclosed plasma parameter distributions using cylindrical Langmuir probes. Their leads were protected by conventional bare shields. Subsequent analysis showed that they distorted xenon plasma lowering all its parameters. Then probe diagnostics was specifically arranged with radially movable straight probe-1 and the additional L-shaped probe-2. They both operated in one special position: shield-1 was absent and shield-2 was non-zero disclosing measurement errors which helped to correct probe-1's data. As the result three new probe applications have been proposed: a) elimination of bare probe protective shield's influence on measurement results (Pat. Applic-n); b) measurements of the probe sheath thicknesses and the mean ion mass using cylindrical probes in Maxwellian plasmas (Patented); c) evaluation of ion current density distributions to an ion extracting electrode of an ion thruster arranged by the plane by-wall probe simulator (Pat. Applic-n). 112 pp. Englisch.…

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing, 2018

    6202197382 / 9786202197380

    • Brossura
    • Print on Demand

    Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 35,74

    EUR 35,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 1 disponibile

    Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Inductive low pressure xenon plasma was generated in an input section of an ion thruster. Its full diagnostics consisted of integral property measurements (Patented) and local plasma parameter determination. Accurate local diagnostics disclosed plasma parameter distributions using cylindrical Langmuir probes. Their leads were protected by conventional bare shields. Subsequent analysis showed that they distorted xenon plasma lowering all its parameters. Then probe diagnostics was specifically arranged with radially movable straight probe-1 and the additional L-shaped probe-2. They both operated in one special position: shield-1 was absent and shield-2 was non-zero disclosing measurement errors which helped to correct probe-1's data. As the result three new probe applications have been proposed: a) elimination of bare probe protective shield's influence on measurement results (Pat. Applic-n); b) measurements of the probe sheath thicknesses and the mean ion mass using cylindrical probes in Maxwellian plasmas (Patented); c) evaluation of ion current density distributions to an ion extracting electrode of an ion thruster arranged by the plane by-wall probe simulator (Pat. Applic-n).…

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing Jan 2018, 2018

    6202197382 / 9786202197380

    • Brossura
    • Print on Demand

    Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germaniabuchversandmimpf2000

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 29,90

    EUR 60,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 1 disponibile

    Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Inductive low pressure xenon plasma was generated in an input section of an ion thruster. Its full diagnostics consisted of integral property measurements (Patented) and local plasma parameter determination. Accurate local diagnostics disclosed plasma parameter distributions using cylindrical Langmuir probes. Their leads were protected by conventional bare shields. Subsequent analysis showed that they distorted xenon plasma lowering all its parameters. Then probe diagnostics was specifically arranged with radially movable straight probe-1 and the additional L-shaped probe-2. They both operated in one special position: shield-1 was absent and shield-2 was non-zero disclosing measurement errors which helped to correct probe-1's data. As the result three new probe applications have been proposed: a) elimination of bare probe protective shield's influence on measurement results (Pat. Applic-n); b) measurements of the probe sheath thicknesses and the mean ion mass using cylindrical probes in Maxwellian plasmas (Patented); c) evaluation of ion current density distributions to an ion extracting electrode of an ion thruster arranged by the plane by-wall probe simulator (Pat. Applic-n).VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 112 pp. Englisch.…