ISBN: 9786202199988 - earthquake response of isolated elevated liquid storage steel tank: analysis using variable frequency pendulum isolator (6 risultati)

- Brossura
Da: Revaluation Books, Exeter, Regno UnitoRevaluation Books
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 66,05
EUR 12,00 spedizioneSpedito da Regno Unito a U.S.A.Quantità: 1 disponibile
Paperback. Condizione: Brand New. 84 pages. 8.66x5.91x0.19 inches. In Stock.

- Brossura
Da: preigu, Osnabrück, Germaniapreigu
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 33,50
EUR 70,00 spedizioneSpedito da Germania a U.S.A.Quantità: 5 disponibili
Taschenbuch. Condizione: Neu. Earthquake Response of Isolated Elevated Liquid Storage Steel Tank | Analysis Using Variable Frequency Pendulum Isolator | Vinayak B. Sutar (u. a.) | Taschenbuch | 84 S. | Englisch | 2018 | LAP LAMBERT Academic Publishing | EAN 9786202199988 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.…

- Brossura
- Print on Demand
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermaniaBuchWeltWeit Ludwig Meier e.K.
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 35,90
EUR 23,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibile
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The seismic response of liquid storage steel tanks with the variable frequency pendulum isolator (VFPI) is compared with that of the same liquid storage steel tanks isolated using the linear elastomeric bearings under real earthquake ground motion. In order to measure the effectiveness of isolation system, the seismic response of isolated steel tanks is compared with that of the non-isolated steel tanks. Two types of isolated tank models are considered in which the bearings are placed at the base and top of the steel tower structure. The seismic response is obtained by the Newmark's step-by-step method. The response of two types of tanks, namely slender and broad tanks, is obtained and a parametric study is carried out to study the effects of important system parameters on the effectiveness of seismic isolation. The parametric study has been carried out to examine the behavior of liquid storage steel tanks isolated with VFPIs. The important parameters considered are the friction coefficient of the VFPI, the Frequency Variation Factor (FVF) and the tank aspect ratio. In less computational efforts the analysis of seismic response for elevated steel tanks is accurately obtained. 84 pp. Englisch.…

- Brossura
- Print on Demand
Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 41,69
EUR 35,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibile
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The seismic response of liquid storage steel tanks with the variable frequency pendulum isolator (VFPI) is compared with that of the same liquid storage steel tanks isolated using the linear elastomeric bearings under real earthquake ground motion. In order to measure the effectiveness of isolation system, the seismic response of isolated steel tanks is compared with that of the non-isolated steel tanks. Two types of isolated tank models are considered in which the bearings are placed at the base and top of the steel tower structure. The seismic response is obtained by the Newmark's step-by-step method. The response of two types of tanks, namely slender and broad tanks, is obtained and a parametric study is carried out to study the effects of important system parameters on the effectiveness of seismic isolation. The parametric study has been carried out to examine the behavior of liquid storage steel tanks isolated with VFPIs. The important parameters considered are the friction coefficient of the VFPI, the Frequency Variation Factor (FVF) and the tank aspect ratio. In less computational efforts the analysis of seismic response for elevated steel tanks is accurately obtained.…

- Brossura
- Print on Demand
Da: moluna, Greven, Germaniamoluna
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 31,27
EUR 48,99 spedizioneSpedito da Germania a U.S.A.Quantità: Più di 20 disponibili
Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Sutar Vinayak B.Mr. Vinayak B. Sutar working as assistant professor in DKTE s TEI, Ichalkaranji, India from last nine years. His research areas are Digital Image Processing, VLSI & Embedded system. This research work is completed in .…

- Brossura
- Print on Demand
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germaniabuchversandmimpf2000
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 35,90
EUR 60,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibile
Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -The seismic response of liquid storage steel tanks with the variable frequency pendulum isolator (VFPI) is compared with that of the same liquid storage steel tanks isolated using the linear elastomeric bearings under real earthquake ground motion. In order to measure the effectiveness of isolation system, the seismic response of isolated steel tanks is compared with that of the non-isolated steel tanks. Two types of isolated tank models are considered in which the bearings are placed at the base and top of the steel tower structure. The seismic response is obtained by the Newmark's step-by-step method. The response of two types of tanks, namely slender and broad tanks, is obtained and a parametric study is carried out to study the effects of important system parameters on the effectiveness of seismic isolation. The parametric study has been carried out to examine the behavior of liquid storage steel tanks isolated with VFPIs. The important parameters considered are the friction coefficient of the VFPI, the Frequency Variation Factor (FVF) and the tank aspect ratio. In less computational efforts the analysis of seismic response for elevated steel tanks is accurately obtained.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 84 pp. Englisch.…