Isbn: 9786204201696 - robust imc/imc-pid controller design: towards load frequency control of perturbed time-delayed power systems using model approximation (5 risultati)

Perfeziona la tua ricerca

  • Libri (5)

  • Nuovo (5)

a

Fascia di prezzo personalizzata (EUR)

a

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing, 2021

    6204201697 / 9786204201696

    • Brossura

    Da: preigu, Osnabrück, Germaniapreigu

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 36,35

    EUR 70,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 5 disponibili

    Taschenbuch. Condizione: Neu. Robust Imc/imc-pid Controller Design | Towards Load Frequency Control of Perturbed Time-delayed Power Systems Using Model Approximation | Vasu Ganji (u. a.) | Taschenbuch | Englisch | 2021 | LAP LAMBERT Academic Publishing | EAN 9786204201696 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing Aug 2021, 2021

    6204201697 / 9786204201696

    • Brossura
    • Print on Demand

    Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermaniaBuchWeltWeit Ludwig Meier e.K.

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 39,90

    EUR 23,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 2 disponibili

    Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Deregulated power system coupled with smart grid technology, for a network Load Frequency Control (LFC) strategy closed-loop feedback is through an open communication channel. The open communication link usually introduces time-delays which degrade the performance of the closed-loop power system and exert to destabilization effect on the overall system. In this book an optimal IMC/IMC-PID control design is proposed for the single-area LFC system with time delay, the design is based on a process reduction control approach, simplifies the design, reduces the computational efforts and also helps in determining the lower order controller. An optimal IMC design methodology is proposed by minimizing ISE between the actual output and the reference input responses of the power system using the EDE algorithm. Finally, PID controller gains are acquired by the least-square model matching with the optimal IMC transfer function. The proposed IMC-PID controller design satisfies reference input tracking performance, robustness in disturbance rejection and improves the dynamic stability of the power system with/without communication delays. 88 pp. Englisch.

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing, 2021

    6204201697 / 9786204201696

    • Brossura
    • Print on Demand

    Da: moluna, Greven, Germaniamoluna

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 34,25

    EUR 48,99 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: Più di 20 disponibili

    Kartoniert / Broschiert. Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Ganji Vasu1) Dr G. Vasu working as an Associate Professor in Raghu Engineering College(A). He published 15-International Journal papers, 08-International and National Conferences, 01-Book. 2) Mr B. Santosh Kumar working as an Assis.

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing, 2021

    6204201697 / 9786204201696

    • Brossura
    • Print on Demand

    Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 58,59

    EUR 35,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 1 disponibili

    Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Deregulated power system coupled with smart grid technology, for a network Load Frequency Control (LFC) strategy closed-loop feedback is through an open communication channel. The open communication link usually introduces time-delays which degrade the performance of the closed-loop power system and exert to destabilization effect on the overall system. In this book an optimal IMC/IMC-PID control design is proposed for the single-area LFC system with time delay, the design is based on a process reduction control approach, simplifies the design, reduces the computational efforts and also helps in determining the lower order controller. An optimal IMC design methodology is proposed by minimizing ISE between the actual output and the reference input responses of the power system using the EDE algorithm. Finally, PID controller gains are acquired by the least-square model matching with the optimal IMC transfer function. The proposed IMC-PID controller design satisfies reference input tracking performance, robustness in disturbance rejection and improves the dynamic stability of the power system with/without communication delays.

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing Aug 2021, 2021

    6204201697 / 9786204201696

    • Brossura
    • Print on Demand

    Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germaniabuchversandmimpf2000

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 39,90

    EUR 60,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 1 disponibili

    Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Deregulated power system coupled with smart grid technology, for a network Load Frequency Control (LFC) strategy closed-loop feedback is through an open communication channel. The open communication link usually introduces time-delays which degrade the performance of the closed-loop power system and exert to destabilization effect on the overall system. In this book an optimal IMC/IMC-PID control design is proposed for the single-area LFC system with time delay, the design is based on a process reduction control approach, simplifies the design, reduces the computational efforts and also helps in determining the lower order controller. An optimal IMC design methodology is proposed by minimizing ISE between the actual output and the reference input responses of the power system using the EDE algorithm. Finally, PID controller gains are acquired by the least-square model matching with the optimal IMC transfer function. The proposed IMC-PID controller design satisfies reference input tracking performance, robustness in disturbance rejection and improves the dynamic stability of the power system with/without communication delays.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 88 pp. Englisch.