Isbn: 9798172040283 - residential duct design handbook: sizing, static pressure, friction rate, and air balancing made practical for hvac contractors, technicians, and homeowners (4 risultati)

Perfeziona la tua ricerca

  • Libri (4)

  • Nuovo (4)

a

Fascia di prezzo personalizzata (EUR)

a

  • Lingua: Inglese

    Editore: Independently published, 2026

    9798172040283

    • Brossura

    Da: PBShop.store UK, Fairford, GLOS, Regno UnitoPBShop.store UK

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 78,45

    EUR 7,86 spedizione 
    Spedito da Regno Unito a U.S.A.

    Quantità: Più di 20 disponibili

    PAP. Condizione: New. New Book. Shipped from UK. Established seller since 2000.

  • Lingua: Inglese

    Editore: Independently Published, 2026

    9798172040283

    • Brossura

    Da: Grand Eagle Retail, Bensenville, IL, U.S.A.Grand Eagle Retail

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 90,48

     Spedizione gratuita 
    Spedito in U.S.A.

    Quantità: 1 disponibili

    Paperback. Condizione: new. Paperback. A duct size can be locally correct and still belong to a poor system. The same bedroom can be starved by an undersized branch, a blocked return path, a loaded filter, a restrictive coil, the wrong blower setting, a closed door, or leakage outside the boundary you thought you were testing. Changing the visible part before the whole path has been mapped is how good money gets spent on the wrong fix.Most residential duct failures are not bad arithmetic. They are a skipped link. A trunk is sized from a guessed tonnage instead of a room load. A fan table is read at the wrong speed or pressure boundary. A filter or coil is counted twice, or not at all. Straight length is mistaken for effective length. Every branch is sized at the same airflow. Flex is selected stretched and installed compressed. The design looks complete while its evidence chain is broken.The Residential Duct Design Handbook rebuilds that chain in eighteen chapters across five parts, from room load to commissioned system. It treats the duct system as one air circuit joined to a fan, coil, filter, terminals, rooms, and doors, and it shows how loads, exact equipment data, a pressure budget, complete supply and return paths, total effective length, a derived friction rate, section sizing, construction details, control states, and field measurements must all agree before a system is finished.Inside, you will learn how to: Build a safe airflow and static-pressure diagnostic map on one page, separating the homeowner observation lane from qualified measurement work.Turn room loads into a reconciled airflow schedule, read blower tables at the right setting, and lock a design airflow the equipment can actually deliver.Calculate total external static pressure from signed readings, budget every component loss exactly once, and derive available static pressure without double subtraction.Measure developed paths, count fittings by actual geometry, find the critical path, and convert available pressure and effective length into a defensible friction rate instead of a universal rule of thumb.Size round, rectangular, flat-oval, and flexible duct at installed conditions, reduce trunk airflow after each takeoff, and check every terminal path against the budget.Design returns that work with closed doors, select grilles, registers, and diffusers from throw and sound data, and carry the design through zoning, variable-speed equipment, heat pumps, and ducted mini-splits in every operating state.Inspect rough-in by critical path, test leakage, measure airflow and pressure with stated uncertainty, balance proportionally, and hand over a package another qualified person can audit.Fifty-five worked examples carry every calculation to a boxed answer. Ninety practice problems are solved in full. All 143 numbered equations are collected in one appendix with their variables, units, and boundaries. Ninety-one figures, more than one hundred tables, six project forms, duct sizing tables, a troubleshooting quick reference, and a subject index support work at the desk and in the crawl space. Four complete cases, a new home, an existing home, a zoned heat pump, and a noise complaint, show the method end to end.Written for HVAC contractors, installers, service technicians, duct designers, commissioning and balancing providers, inspectors, apprentices, and technically engaged homeowners who want to know what qualified work should produce. The workflow follows United States residential practice in inch-pound units with SI equivalents, and an appendix maps units, terminology, and local pathways for Canada, the United Kingdom, Australia, and New Zealand.Stop guessing at the trunk size and start proving the whole path. Click the " Shipping may be from multiple locations in the US or from the UK, depending on stock availability.…

  • Lingua: Inglese

    Editore: Independently Published, 2026

    9798172040283

    • Brossura

    Da: CitiRetail, Stevenage, Regno UnitoCitiRetail

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 84,44

    EUR 43,04 spedizione 
    Spedito da Regno Unito a U.S.A.

    Quantità: 1 disponibili

    Paperback. Condizione: new. Paperback. A duct size can be locally correct and still belong to a poor system. The same bedroom can be starved by an undersized branch, a blocked return path, a loaded filter, a restrictive coil, the wrong blower setting, a closed door, or leakage outside the boundary you thought you were testing. Changing the visible part before the whole path has been mapped is how good money gets spent on the wrong fix.Most residential duct failures are not bad arithmetic. They are a skipped link. A trunk is sized from a guessed tonnage instead of a room load. A fan table is read at the wrong speed or pressure boundary. A filter or coil is counted twice, or not at all. Straight length is mistaken for effective length. Every branch is sized at the same airflow. Flex is selected stretched and installed compressed. The design looks complete while its evidence chain is broken.The Residential Duct Design Handbook rebuilds that chain in eighteen chapters across five parts, from room load to commissioned system. It treats the duct system as one air circuit joined to a fan, coil, filter, terminals, rooms, and doors, and it shows how loads, exact equipment data, a pressure budget, complete supply and return paths, total effective length, a derived friction rate, section sizing, construction details, control states, and field measurements must all agree before a system is finished.Inside, you will learn how to: Build a safe airflow and static-pressure diagnostic map on one page, separating the homeowner observation lane from qualified measurement work.Turn room loads into a reconciled airflow schedule, read blower tables at the right setting, and lock a design airflow the equipment can actually deliver.Calculate total external static pressure from signed readings, budget every component loss exactly once, and derive available static pressure without double subtraction.Measure developed paths, count fittings by actual geometry, find the critical path, and convert available pressure and effective length into a defensible friction rate instead of a universal rule of thumb.Size round, rectangular, flat-oval, and flexible duct at installed conditions, reduce trunk airflow after each takeoff, and check every terminal path against the budget.Design returns that work with closed doors, select grilles, registers, and diffusers from throw and sound data, and carry the design through zoning, variable-speed equipment, heat pumps, and ducted mini-splits in every operating state.Inspect rough-in by critical path, test leakage, measure airflow and pressure with stated uncertainty, balance proportionally, and hand over a package another qualified person can audit.Fifty-five worked examples carry every calculation to a boxed answer. Ninety practice problems are solved in full. All 143 numbered equations are collected in one appendix with their variables, units, and boundaries. Ninety-one figures, more than one hundred tables, six project forms, duct sizing tables, a troubleshooting quick reference, and a subject index support work at the desk and in the crawl space. Four complete cases, a new home, an existing home, a zoned heat pump, and a noise complaint, show the method end to end.Written for HVAC contractors, installers, service technicians, duct designers, commissioning and balancing providers, inspectors, apprentices, and technically engaged homeowners who want to know what qualified work should produce. The workflow follows United States residential practice in inch-pound units with SI equivalents, and an appendix maps units, terminology, and local pathways for Canada, the United Kingdom, Australia, and New Zealand.Stop guessing at the trunk size and start proving the whole path. < Shipping may be from our UK warehouse or from our Australian or US warehouses, depending on stock availability.…

  • Lingua: Inglese

    Editore: Independently published, 2026

    9798172040283

    • Brossura
    • Print on Demand

    Da: California Books, Miami, FL, U.S.A.California Books

    Venditore con 4 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 88,69

     Spedizione gratuita 
    Spedito in U.S.A.

    Quantità: Più di 20 disponibili

    Condizione: New. Print on Demand.