ISBN: 9798173517258 - protective relay testing and commissioning: practical methods for protection verification, troubleshooting, and substation energization (6 risultati)

- Brossura
Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 139,21
EUR 35,00 spedizioneSpedito da Germania a U.S.A.Quantità: 2 disponibili
Taschenbuch. Condizione: Neu. Neuware - A protective relay does nothing visible for almost all of its service life. It measures, compares, and waits - and then, in the brief and violent moment a fault arrives, everything depends on whether the protection was proven correctly before it went into service. The gap between a relay that is configured correctly and a protection scheme that actually works is wide, and it is where commissioning failures hide. A setting that is right on paper means little if a current transformer is wired with reversed polarity, if a trip contact lands on the wrong breaker, if a communications channel behaves unexpectedly, or if a single logic equation is wrong. Rote, menu-driven procedures collapse the moment the equipment, scheme, or symptom differs from the example.>What you will be able to do: - Verify the full measurement-to-trip chain, from instrument transformers through relay logic to breaker operation.- Test overcurrent (50/51), differential (87), and distance (21) protection, including inverse-time curves, restraint characteristics, harmonic/inrush security, and boundary searches.- Prove synchronism-check, dead-bus/dead-line logic, and communications-assisted scheme behaviour end to end.- Carry out safe secondary and primary injection with correct isolation, test blocks, and trip-path control.- Plan and time distributed, multi-terminal end-to-end tests, then move a scheme through pre-energization readiness, staged energization, and clean handover.- Investigate misoperations with event timelines, oscillography, and a competing-hypotheses method, and build a maintenance programme that keeps protection dependable.>Written for relay test technicians, protection and control engineers, and substation commissioning engineers - and suitable for advanced students entering the field - this is the first-principles reference for anyone who must prove a scheme before it is trusted. Take the next step toward testing and commissioning protection with clarity and confidence: open the book and start building tests that are rigorous, repeatable, and understood.…

- Brossura
- Print on Demand
Da: Grand Eagle Retail, Bensenville, IL, U.S.A.Grand Eagle Retail
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 80,81
Spedizione gratuitaSpedito in U.S.A.Quantità: 1 disponibile
Paperback. Condizione: new. Paperback. A protective relay does nothing visible for almost all of its service life. It measures, compares, and waits - and then, in the brief and violent moment a fault arrives, everything depends on whether the protection was proven correctly before it went into service. The gap between a relay that is configured correctly and a protection scheme that actually works is wide, and it is where commissioning failures hide. A setting that is right on paper means little if a current transformer is wired with reversed polarity, if a trip contact lands on the wrong breaker, if a communications channel behaves unexpectedly, or if a single logic equation is wrong. Rote, menu-driven procedures collapse the moment the equipment, scheme, or symptom differs from the example.This comprehensive, practical guide closes that gap. It treats testing and commissioning as a disciplined process of establishing evidence that a protection scheme behaves exactly as its approved design requires. Every protection function is developed from its operating principle - through the quantities and logic you must verify - to suitable test methods and the interpretation of results, so you can reason about an unfamiliar relay instead of memorising one model's buttons. What you will be able to do: Verify the full measurement-to-trip chain, from instrument transformers through relay logic to breaker operation.Test overcurrent (50/51), differential (87), and distance (21) protection, including inverse-time curves, restraint characteristics, harmonic/inrush security, and boundary searches.Prove synchronism-check, dead-bus/dead-line logic, and communications-assisted scheme behaviour end to end.Carry out safe secondary and primary injection with correct isolation, test blocks, and trip-path control.Plan and time distributed, multi-terminal end-to-end tests, then move a scheme through pre-energization readiness, staged energization, and clean handover.Investigate misoperations with event timelines, oscillography, and a competing-hypotheses method, and build a maintenance programme that keeps protection dependable.The treatment is deliberately manufacturer-neutral, so the methods stay valid across relay generations and vendors while you take specific settings and tolerances from your own controlling documents. Worked examples, practice problems, answer keys, and standards references appear throughout. Written for relay test technicians, protection and control engineers, and substation commissioning engineers - and suitable for advanced students entering the field - this is the first-principles reference for anyone who must prove a scheme before it is trusted. Take the next step toward testing and commissioning protection with clarity and confidence: open the book and start building tests that are rigorous, repeatable, and understood. This item is printed on demand. Shipping may be from multiple locations in the US or from the UK, depending on stock availability.…

- Brossura
- Print on Demand
Da: California Books, Miami, FL, U.S.A.California Books
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 79,99
EUR 2,68 spedizioneSpedito in U.S.A.Quantità: Più di 20 disponibili
Condizione: New. Print on Demand.

- Brossura
- Print on Demand
Da: PBShop.store US, Wood Dale, IL, U.S.A.PBShop.store US
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 100,23
Spedizione gratuitaSpedito in U.S.A.Quantità: Più di 20 disponibili
PAP. Condizione: New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000.

- Brossura
- Print on Demand
Da: PBShop.store UK, Fairford, GLOS, Regno UnitoPBShop.store UK
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 94,96
EUR 5,99 spedizioneSpedito da Regno Unito a U.S.A.Quantità: Più di 20 disponibili
PAP. Condizione: New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000.

- Brossura
- Print on Demand
Da: CitiRetail, Stevenage, Regno UnitoCitiRetail
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 91,00
EUR 44,18 spedizioneSpedito da Regno Unito a U.S.A.Quantità: 1 disponibile
Paperback. Condizione: new. Paperback. A protective relay does nothing visible for almost all of its service life. It measures, compares, and waits - and then, in the brief and violent moment a fault arrives, everything depends on whether the protection was proven correctly before it went into service. The gap between a relay that is configured correctly and a protection scheme that actually works is wide, and it is where commissioning failures hide. A setting that is right on paper means little if a current transformer is wired with reversed polarity, if a trip contact lands on the wrong breaker, if a communications channel behaves unexpectedly, or if a single logic equation is wrong. Rote, menu-driven procedures collapse the moment the equipment, scheme, or symptom differs from the example.This comprehensive, practical guide closes that gap. It treats testing and commissioning as a disciplined process of establishing evidence that a protection scheme behaves exactly as its approved design requires. Every protection function is developed from its operating principle - through the quantities and logic you must verify - to suitable test methods and the interpretation of results, so you can reason about an unfamiliar relay instead of memorising one model's buttons. What you will be able to do: Verify the full measurement-to-trip chain, from instrument transformers through relay logic to breaker operation.Test overcurrent (50/51), differential (87), and distance (21) protection, including inverse-time curves, restraint characteristics, harmonic/inrush security, and boundary searches.Prove synchronism-check, dead-bus/dead-line logic, and communications-assisted scheme behaviour end to end.Carry out safe secondary and primary injection with correct isolation, test blocks, and trip-path control.Plan and time distributed, multi-terminal end-to-end tests, then move a scheme through pre-energization readiness, staged energization, and clean handover.Investigate misoperations with event timelines, oscillography, and a competing-hypotheses method, and build a maintenance programme that keeps protection dependable.The treatment is deliberately manufacturer-neutral, so the methods stay valid across relay generations and vendors while you take specific settings and tolerances from your own controlling documents. Worked examples, practice problems, answer keys, and standards references appear throughout. Written for relay test technicians, protection and control engineers, and substation commissioning engineers - and suitable for advanced students entering the field - this is the first-principles reference for anyone who must prove a scheme before it is trusted. Take the next step toward testing and commissioning protection with clarity and confidence: open the book and start building tests that are rigorous, repeatable, and understood. This item is printed on demand. Shipping may be from our UK warehouse or from our Australian or US warehouses, depending on stock availability.…