ISBN: 9798185528761 - an introduction to refrigeration systems design for professional engineers (4 risultati)

Perfeziona la tua ricerca

  • Libri (4)

  • Nuovo (4)

a

Fascia di prezzo personalizzata (EUR)

a

  • Lingua: Inglese

    Editore: Amazon Digital Services LLC - Kdp Jul 2026, 2026

    9798185528761

    Serie: Libro 24 di 24 - Mechanical Engineering

    • Brossura

    Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 63,45

    EUR 35,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 2 disponibili

    Taschenbuch. Condizione: Neu. Neuware - his section addresses the general requirements for the design and selection of a refrigerated system for cold storage. ASHRAE Standards and Handbook are the basis for refrigeration system design, selection, installation, testing, and operating. For ammonia systems, the standards of the International Institute of Ammonia Refrigerators (IIAR) will apply, and if more stringent than ASHRAE Standards, IIAR will prevail. Design new refrigerated facilities to meet the considerations for building design that are provided in the refrigerated facility design chapter of ASHRAE Handbook - Refrigeration. Cold storage facilities held below freezing can cause under floor ice formation, resulting in floor upheaval. Design sub-floor freeze protection for facilities that are held below freezing, such as air duct systems, electrical heating systems, or heated pipe grids. These systems are detailed in the above-mentioned chapter. Comply with all ASHRAE Standard 15 in its entirety, including but not limited to equipment placement, ventilation design, door and passageway restrictions, refrigerant monitoring, flame devices, pressure relief and purge piping, refrigerant piping, signs, self-contained breathing apparatus (SCBA), and miscellaneous installation restrictions.…

  • Lingua: Inglese

    Editore: Independently Published, 2026

    9798185528761

    Serie: Libro 24 di 24 - Mechanical Engineering

    • Brossura
    • Print on Demand

    Da: Grand Eagle Retail, Bensenville, IL, U.S.A.Grand Eagle Retail

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 48,70

     Spedizione gratuita 
    Spedito in U.S.A.

    Quantità: 1 disponibile

    Paperback. Condizione: new. Paperback. his section addresses the general requirements for the design and selection of a refrigerated system for cold storage. ASHRAE Standards and Handbook are the basis for refrigeration system design, selection, installation, testing, and operating. For ammonia systems, the standards of the International Institute of Ammonia Refrigerators (IIAR) will apply, and if more stringent than ASHRAE Standards, IIAR will prevail. Design new refrigerated facilities to meet the considerations for building design that are provided in the refrigerated facility design chapter of ASHRAE Handbook - Refrigeration. Cold storage facilities held below freezing can cause under floor ice formation, resulting in floor upheaval. Design sub-floor freeze protection for facilities that are held below freezing, such as air duct systems, electrical heating systems, or heated pipe grids. These systems are detailed in the above-mentioned chapter. Comply with all ASHRAE Standard 15 in its entirety, including but not limited to equipment placement, ventilation design, door and passageway restrictions, refrigerant monitoring, flame devices, pressure relief and purge piping, refrigerant piping, signs, self-contained breathing apparatus (SCBA), and miscellaneous installation restrictions. This item is printed on demand. Shipping may be from multiple locations in the US or from the UK, depending on stock availability.…

  • Lingua: Inglese

    Editore: Independently published, 2026

    9798185528761

    Serie: Libro 24 di 24 - Mechanical Engineering

    • Brossura
    • Print on Demand

    Da: California Books, Miami, FL, U.S.A.California Books

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 49,63

    EUR 2,68 spedizione 
    Spedito in U.S.A.

    Quantità: Più di 20 disponibili

    Condizione: New. Print on Demand.

  • Lingua: Inglese

    Editore: Independently Published, 2026

    9798185528761

    Serie: Libro 24 di 24 - Mechanical Engineering

    • Brossura
    • Print on Demand

    Da: CitiRetail, Stevenage, Regno UnitoCitiRetail

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 56,78

    EUR 44,35 spedizione 
    Spedito da Regno Unito a U.S.A.

    Quantità: 1 disponibile

    Paperback. Condizione: new. Paperback. his section addresses the general requirements for the design and selection of a refrigerated system for cold storage. ASHRAE Standards and Handbook are the basis for refrigeration system design, selection, installation, testing, and operating. For ammonia systems, the standards of the International Institute of Ammonia Refrigerators (IIAR) will apply, and if more stringent than ASHRAE Standards, IIAR will prevail. Design new refrigerated facilities to meet the considerations for building design that are provided in the refrigerated facility design chapter of ASHRAE Handbook - Refrigeration. Cold storage facilities held below freezing can cause under floor ice formation, resulting in floor upheaval. Design sub-floor freeze protection for facilities that are held below freezing, such as air duct systems, electrical heating systems, or heated pipe grids. These systems are detailed in the above-mentioned chapter. Comply with all ASHRAE Standard 15 in its entirety, including but not limited to equipment placement, ventilation design, door and passageway restrictions, refrigerant monitoring, flame devices, pressure relief and purge piping, refrigerant piping, signs, self-contained breathing apparatus (SCBA), and miscellaneous installation restrictions. This item is printed on demand. Shipping may be from our UK warehouse or from our Australian or US warehouses, depending on stock availability.…