ISBN: 9798185528761 - an introduction to refrigeration systems design for professional engineers (4 risultati)

Lingua: Inglese
Editore: Amazon Digital Services LLC - Kdp Jul 2026, 2026
- Brossura
Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 63,45
EUR 35,00 spedizioneSpedito da Germania a U.S.A.Quantità: 2 disponibili
Taschenbuch. Condizione: Neu. Neuware - his section addresses the general requirements for the design and selection of a refrigerated system for cold storage. ASHRAE Standards and Handbook are the basis for refrigeration system design, selection, installation, testing, and operating. For ammonia systems, the standards of the International Institute of Ammonia Refrigerators (IIAR) will apply, and if more stringent than ASHRAE Standards, IIAR will prevail. Design new refrigerated facilities to meet the considerations for building design that are provided in the refrigerated facility design chapter of ASHRAE Handbook - Refrigeration. Cold storage facilities held below freezing can cause under floor ice formation, resulting in floor upheaval. Design sub-floor freeze protection for facilities that are held below freezing, such as air duct systems, electrical heating systems, or heated pipe grids. These systems are detailed in the above-mentioned chapter. Comply with all ASHRAE Standard 15 in its entirety, including but not limited to equipment placement, ventilation design, door and passageway restrictions, refrigerant monitoring, flame devices, pressure relief and purge piping, refrigerant piping, signs, self-contained breathing apparatus (SCBA), and miscellaneous installation restrictions.…

Lingua: Inglese
Editore: Independently Published, 2026
- Brossura
- Print on Demand
Da: Grand Eagle Retail, Bensenville, IL, U.S.A.Grand Eagle Retail
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 48,70
Spedizione gratuitaSpedito in U.S.A.Quantità: 1 disponibile
Paperback. Condizione: new. Paperback. his section addresses the general requirements for the design and selection of a refrigerated system for cold storage. ASHRAE Standards and Handbook are the basis for refrigeration system design, selection, installation, testing, and operating. For ammonia systems, the standards of the International Institute of Ammonia Refrigerators (IIAR) will apply, and if more stringent than ASHRAE Standards, IIAR will prevail. Design new refrigerated facilities to meet the considerations for building design that are provided in the refrigerated facility design chapter of ASHRAE Handbook - Refrigeration. Cold storage facilities held below freezing can cause under floor ice formation, resulting in floor upheaval. Design sub-floor freeze protection for facilities that are held below freezing, such as air duct systems, electrical heating systems, or heated pipe grids. These systems are detailed in the above-mentioned chapter. Comply with all ASHRAE Standard 15 in its entirety, including but not limited to equipment placement, ventilation design, door and passageway restrictions, refrigerant monitoring, flame devices, pressure relief and purge piping, refrigerant piping, signs, self-contained breathing apparatus (SCBA), and miscellaneous installation restrictions. This item is printed on demand. Shipping may be from multiple locations in the US or from the UK, depending on stock availability.…

Lingua: Inglese
Editore: Independently published, 2026
- Brossura
- Print on Demand
Da: California Books, Miami, FL, U.S.A.California Books
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 49,63
EUR 2,68 spedizioneSpedito in U.S.A.Quantità: Più di 20 disponibili
Condizione: New. Print on Demand.

Lingua: Inglese
Editore: Independently Published, 2026
- Brossura
- Print on Demand
Da: CitiRetail, Stevenage, Regno UnitoCitiRetail
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 56,78
EUR 44,35 spedizioneSpedito da Regno Unito a U.S.A.Quantità: 1 disponibile
Paperback. Condizione: new. Paperback. his section addresses the general requirements for the design and selection of a refrigerated system for cold storage. ASHRAE Standards and Handbook are the basis for refrigeration system design, selection, installation, testing, and operating. For ammonia systems, the standards of the International Institute of Ammonia Refrigerators (IIAR) will apply, and if more stringent than ASHRAE Standards, IIAR will prevail. Design new refrigerated facilities to meet the considerations for building design that are provided in the refrigerated facility design chapter of ASHRAE Handbook - Refrigeration. Cold storage facilities held below freezing can cause under floor ice formation, resulting in floor upheaval. Design sub-floor freeze protection for facilities that are held below freezing, such as air duct systems, electrical heating systems, or heated pipe grids. These systems are detailed in the above-mentioned chapter. Comply with all ASHRAE Standard 15 in its entirety, including but not limited to equipment placement, ventilation design, door and passageway restrictions, refrigerant monitoring, flame devices, pressure relief and purge piping, refrigerant piping, signs, self-contained breathing apparatus (SCBA), and miscellaneous installation restrictions. This item is printed on demand. Shipping may be from our UK warehouse or from our Australian or US warehouses, depending on stock availability.…