Analytical method development validation di sharma gagan (6 risultati)

- Brossura
Da: preigu, Osnabrück, Germaniapreigu
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 42,65
EUR 70,00 spedizioneSpedito da Germania a U.S.A.Quantità: 5 disponibili
Taschenbuch. Condizione: Neu. Analytical Method Development and Validation | Simultaneous Estimation of Pioglitazone and Glimepiride in Tablet Dosage Form by RP-HPLC | Gagan Sharma (u. a.) | Taschenbuch | 112 S. | Englisch | 2012 | LAP LAMBERT Academic Publishing | EAN 9783659253997 | Verantwortliche Person für die EU: preigu Gm…bH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.

- Brossura
Da: Mispah books, Redhill, SURRE, Regno UnitoMispah books
Contatta il venditoreVenditore con 4 stelleCondizione: Nuovo
EUR 171,96
EUR 29,19 spedizioneSpedito da Regno Unito a U.S.A.Quantità: 1 disponibili
paperback. Condizione: New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book.

- Brossura
- Print on Demand
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermaniaBuchWeltWeit Ludwig Meier e.K.
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 49,00
EUR 23,00 spedizioneSpedito da Germania a U.S.A.Quantità: 2 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -A simple reverse phase liquid Chromatographic method has been developed and subsequently validated for simultaneous determination of Pioglitazone and Glimepiride in combination. The separation was carried out using a mobile phase o…f phosphate buffer (pH-4.5): Acetonitrile (45:55) v/v and using methanol as diluent. The column used was Inertsil ODS (250 mm x 4.6 mm i.d., 5 m) with flow rate of 1 ml/min using UV detection at 225 nm. The described method was linear over a concentration range of 5-50 g/ml and 5-25 g/ml for the assay of Pioglitazone and Glimepiride respectively. The retention times of Pioglitazone and Glimepiride were found to be4.6 and 7.7min respectively. Results of analysis were validated statistically and by recovery studies. The results of the study showed that the proposed RP-HPLC method is simple, rapid, precise and accurate, which is useful for the routine determination of Pioglitazone and Glimepiride bulk drug and in its pharmaceutical dosage form. 112 pp. Englisch.

- Brossura
- Print on Demand
Da: moluna, Greven, Germaniamoluna
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 41,05
EUR 48,99 spedizioneSpedito da Germania a U.S.A.Quantità: Più di 20 disponibili
Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Sharma GaganGagan Sharma is a young dynamic amateur researcher, born on 19 Nov. 1985. Gagan has earned Master of Pharmacy (Pharmaceutical chemistry) from NMIMS University Mumbai (India). Gagan has exte…nsive exposer in pharmaceutical.

- Brossura
- Print on Demand
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germaniabuchversandmimpf2000
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 49,00
EUR 60,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -A simple reverse phase liquid Chromatographic method has been developed and subsequently validated for simultaneous determination of Pioglitazone and Glimepiride in combination. The separation was carried out using a mobile phase of ph…osphate buffer (pH-4.5): Acetonitrile (45:55) v/v and using methanol as diluent. The column used was Inertsil ODS (250 mm x 4.6 mm i.d., 5¿m) with flow rate of 1 ml/min using UV detection at 225 nm. The described method was linear over a concentration range of 5-50¿g/ml and 5-25 ¿g/ml for the assay of Pioglitazone and Glimepiride respectively. The retention times of Pioglitazone and Glimepiride were found to be4.6 and 7.7min respectively. Results of analysis were validated statistically and by recovery studies. The results of the study showed that the proposed RP-HPLC method is simple, rapid, precise and accurate, which is useful for the routine determination of Pioglitazone and Glimepiride bulk drug and in its pharmaceutical dosage form.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 112 pp. Englisch.

- Brossura
- Print on Demand
Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 49,00
EUR 60,93 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibili
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - A simple reverse phase liquid Chromatographic method has been developed and subsequently validated for simultaneous determination of Pioglitazone and Glimepiride in combination. The separation was carried out using a mobile phase of pho…sphate buffer (pH-4.5): Acetonitrile (45:55) v/v and using methanol as diluent. The column used was Inertsil ODS (250 mm x 4.6 mm i.d., 5 m) with flow rate of 1 ml/min using UV detection at 225 nm. The described method was linear over a concentration range of 5-50 g/ml and 5-25 g/ml for the assay of Pioglitazone and Glimepiride respectively. The retention times of Pioglitazone and Glimepiride were found to be4.6 and 7.7min respectively. Results of analysis were validated statistically and by recovery studies. The results of the study showed that the proposed RP-HPLC method is simple, rapid, precise and accurate, which is useful for the routine determination of Pioglitazone and Glimepiride bulk drug and in its pharmaceutical dosage form.