In order to rea1ize real-time medica1 imaging systems, such as are used for computed tomography, automated miscroscopy, dynamic radioisotope imaging, etc., special techno1ogy is required. The high-speed image sour ce must be successfu11y married with the u1tra high-speed computer. Usua11y the ordinary genera1-purpose computer is found to be inadequate to the image generation and/or image pro cessing task. The ordinary computer executes instructions at be tween 1 and 10 million per second. Speed has improved by only about a factor of 10 during the past 20 years. In contrast a typical com puter used in recognizing blood cell images at 10,000 per hour must execute instructions at between 1 billion and 10 billion per second. Simi1ar execution rates are required to construct a computed tomogra phy image in real-time (1 to 10 seconds). For the reasons given above, engineering development in image generation and processing in the field of biomedicine has become a discipline unto itself; a discipline wherein the computer engineer is driven to design extremely high-speed machines that far surpass the ordinary computer and the x-ray, radioisotope, or microscope scanner designer must also produce equipment whose specifications extend far beyond the state-of-the-art.
Le informazioni nella sezione "Riassunto" possono far riferimento a edizioni diverse di questo titolo.
General.- Towards an Image Analysis Center for Medicine.- Cellular Computers and Biomedical Image Processing.- Radiology.- Ultra High-Speed Reconstruction Processors for X-Ray Computed Tomography of the Heart and Circulation.- Computer Analysis of the Ultrasonic Echocardiogram.- Toward Computed Detection of Nodules in Chest Radiographs.- A Parallel Processing System for the Three-Dimensional Display of Serial Tomograms.- Dynamic Computed Tomography for the Heart.- Efficient Analysis of Dynamic Images Using Plans.- Real-Time Image Processing in CT-Convolver and Back Projector.- Histology and Cytology.- Detection of the Spherical Size Distribution of Hormone Secretory Granules from Electron Micrographs.- The Abbott Laboratories ADC-500T.M..- An Approach to Automated Cytotoxicity Testing by Means of Digital Image Processing.- The diff3T.M. Analyzer: A Parallel/Serial Golay Image Processor.- Computer-Aided Tissue Stereology.- Interactive System for Medical Image Processing.- Real-Time Image Processing in Automated Cytology.- The Development of a New Model Cyto-Prescreener for Cervical Cancer.- Author Index.
Le informazioni nella sezione "Su questo libro" possono far riferimento a edizioni diverse di questo titolo.
Da: Brook Bookstore On Demand, Napoli, NA, Italia
Condizione: new. Questo è un articolo print on demand. Codice articolo F0WNYKW2NA
Quantità: Più di 20 disponibili
Da: GreatBookPrices, Columbia, MD, U.S.A.
Condizione: New. Codice articolo 21687739-n
Quantità: 15 disponibili
Da: California Books, Miami, FL, U.S.A.
Condizione: New. Codice articolo I-9781475701234
Quantità: Più di 20 disponibili
Da: Chiron Media, Wallingford, Regno Unito
PF. Condizione: New. This item is printed on demand. Brand new book, sourced directly from publisher. Dispatch time is 6-7 days from our warehouse. Book will be sent in robust, secure packaging to ensure it reaches you securely. Codice articolo 6666-IUK-9781475701234
Quantità: 20 disponibili
Da: GreatBookPrices, Columbia, MD, U.S.A.
Condizione: As New. Unread book in perfect condition. Codice articolo 21687739
Quantità: 15 disponibili
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germania
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -In order to rea1ize real-time medica1 imaging systems, such as are used for computed tomography, automated miscroscopy, dynamic radioisotope imaging, etc., special techno1ogy is required. The high-speed image sour ce must be successfu11y married with the u1tra high-speed computer. Usua11y the ordinary genera1-purpose computer is found to be inadequate to the image generation and/or image pro cessing task. The ordinary computer executes instructions at be tween 1 and 10 million per second. Speed has improved by only about a factor of 10 during the past 20 years. In contrast a typical com puter used in recognizing blood cell images at 10,000 per hour must execute instructions at between 1 billion and 10 billion per second. Simi1ar execution rates are required to construct a computed tomogra phy image in real-time (1 to 10 seconds). For the reasons given above, engineering development in image generation and processing in the field of biomedicine has become a discipline unto itself; a discipline wherein the computer engineer is driven to design extremely high-speed machines that far surpass the ordinary computer and the x-ray, radioisotope, or microscope scanner designer must also produce equipment whose specifications extend far beyond the state-of-the-art. 272 pp. Englisch. Codice articolo 9781475701234
Quantità: 2 disponibili
Da: Ria Christie Collections, Uxbridge, Regno Unito
Condizione: New. In English. Codice articolo ria9781475701234_new
Quantità: Più di 20 disponibili
Da: Books Puddle, Woodside, NY, U.S.A.
Condizione: New. pp. 272. Codice articolo 26127087033
Quantità: 4 disponibili
Da: Revaluation Books, Exeter, Regno Unito
Paperback. Condizione: Brand New. reprint edition. 260 pages. 10.00x7.01x0.64 inches. In Stock. Codice articolo x-1475701233
Quantità: 2 disponibili
Da: Majestic Books, Hounslow, Regno Unito
Condizione: New. Print on Demand pp. 272. Codice articolo 132419174
Quantità: 4 disponibili