Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germania
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Distribution networks are typically of two types; radial or interconnected. A radial network leaves the station and passes through the network area with no normal connection to any other supply. However, an interconnected network will have numerous connections to other points of supply. These points of connection are normally open but allow various configurations by the operating utility by closing and opening switches. In distribution systems, the voltage at buses reduces when we leave from the substation, due to high distribution line current thus resulting high power loss in the line.The I2R loss can be, separated into two parts based on the active and reactive components of branch currents. This thesis work presents a method of minimizing the loss associated with the reactive component of branch currents by an appropriate loss reduction mechanism. It includes the objective of identifying the optimal locations and sizes of loss compensator, to be placed in network with the consideration of net cost savings. Finally, it benefits both the utilities and consumers; by improving power system losses, net cost saving, reducing the belling cost and hence saves their equipment failure. 148 pp. Englisch. Codice articolo 9783659455025
Quantità: 2 disponibili
Da: moluna, Greven, Germania
Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Tella Teshome GoaTeshome Goa. M.Sc. in Electrical Power Engineering, studied at: Adama Science and Technology University, Ethiopia, Electrical Power Engineering Chair holder at Mekelle University, Ethiopia.Distribution networks a. Codice articolo 385767014
Quantità: Più di 20 disponibili
Da: Books Puddle, New York, NY, U.S.A.
Condizione: New. Codice articolo 26377825393
Quantità: 4 disponibili
Da: Majestic Books, Hounslow, Regno Unito
Condizione: New. Print on Demand. Codice articolo 384997294
Quantità: 4 disponibili
Da: Biblios, Frankfurt am main, HESSE, Germania
Condizione: New. PRINT ON DEMAND. Codice articolo 18377825403
Quantità: 4 disponibili
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germania
Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Distribution networks are typically of two types; radial or interconnected. A radial network leaves the station and passes through the network area with no normal connection to any other supply. However, an interconnected network will have numerous connections to other points of supply. These points of connection are normally open but allow various configurations by the operating utility by closing and opening switches. In distribution systems, the voltage at buses reduces when we leave from the substation, due to high distribution line current thus resulting high power loss in the line.The I2R loss can be, separated into two parts based on the active and reactive components of branch currents. This thesis work presents a method of minimizing the loss associated with the reactive component of branch currents by an appropriate loss reduction mechanism. It includes the objective of identifying the optimal locations and sizes of loss compensator, to be placed in network with the consideration of net cost savings. Finally, it benefits both the utilities and consumers; by improving power system losses, net cost saving, reducing the belling cost and hence saves their equipment failure.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 148 pp. Englisch. Codice articolo 9783659455025
Quantità: 1 disponibili
Da: AHA-BUCH GmbH, Einbeck, Germania
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Distribution networks are typically of two types; radial or interconnected. A radial network leaves the station and passes through the network area with no normal connection to any other supply. However, an interconnected network will have numerous connections to other points of supply. These points of connection are normally open but allow various configurations by the operating utility by closing and opening switches. In distribution systems, the voltage at buses reduces when we leave from the substation, due to high distribution line current thus resulting high power loss in the line.The I2R loss can be, separated into two parts based on the active and reactive components of branch currents. This thesis work presents a method of minimizing the loss associated with the reactive component of branch currents by an appropriate loss reduction mechanism. It includes the objective of identifying the optimal locations and sizes of loss compensator, to be placed in network with the consideration of net cost savings. Finally, it benefits both the utilities and consumers; by improving power system losses, net cost saving, reducing the belling cost and hence saves their equipment failure. Codice articolo 9783659455025
Quantità: 1 disponibili
Da: preigu, Osnabrück, Germania
Taschenbuch. Condizione: Neu. An Optimal Power Loss Reduction by Using Shunt Capacitor | Power Loss Reduction by Considering the Cost Savings | Teshome Goa Tella | Taschenbuch | 148 S. | Englisch | 2018 | LAP LAMBERT Academic Publishing | EAN 9783659455025 | Verantwortliche Person für die EU: BoD - Books on Demand, In de Tarpen 42, 22848 Norderstedt, info[at]bod[dot]de | Anbieter: preigu. Codice articolo 113818854
Quantità: 5 disponibili