The use of XLPE insulation for high voltage and extra high voltage power cables is increasing. The new cable systems are installed in the field and inaccurate assembling of cable accessories could result in the precence of deffects.The after laying test is performed in the new cable system to check the quality of cable system installation.Also partial discharge test is usually carried out after cable system maintenance. In this book the author used a new technology for on-site withstand tests and partial discharge measurement of XLPE underground power cable system.In this book two methods of testing are presented ,power frequency test and variable frequency (20-300 Hz)test.
Le informazioni nella sezione "Riassunto" possono far riferimento a edizioni diverse di questo titolo.
Dr.Ossama El-Sayed Gouda is the professor of electrical Power engineering and high voltage in the Dept.of Electrical power,Faculty of Engineering,Cairo University since 1993.He conducted more than 110 papers in the field of Electrical power and High voltage engineering.Now he is the head of High Voltage Group,Cairo university
Dr.Ossama El-Sayed Gouda is the professor of electrical Power engineering and high voltage in the Dept.of Electrical power,Faculty of Engineering,Cairo University since 1993.He conducted more than 110 papers in the field of Electrical power and High voltage engineering.Now he is the head of High Voltage Group,Cairo university
Le informazioni nella sezione "Su questo libro" possono far riferimento a edizioni diverse di questo titolo.
Da: Lucky's Textbooks, Dallas, TX, U.S.A.
Condizione: New. Codice articolo ABLING22Oct2817100617667
Quantità: Più di 20 disponibili
Da: PBShop.store US, Wood Dale, IL, U.S.A.
PAP. Condizione: New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Codice articolo L0-9783844397994
Quantità: Più di 20 disponibili
Da: PBShop.store UK, Fairford, GLOS, Regno Unito
PAP. Condizione: New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Codice articolo L0-9783844397994
Quantità: Più di 20 disponibili
Da: Ria Christie Collections, Uxbridge, Regno Unito
Condizione: New. In. Codice articolo ria9783844397994_new
Quantità: Più di 20 disponibili
Da: Chiron Media, Wallingford, Regno Unito
Paperback. Condizione: New. Codice articolo 6666-IUK-9783844397994
Quantità: 10 disponibili
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germania
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The use of XLPE insulation for high voltage and extra high voltage power cables is increasing. The new cable systems are installed in the field and inaccurate assembling of cable accessories could result in the precence of deffects.The after laying test is performed in the new cable system to check the quality of cable system installation.Also partial discharge test is usually carried out after cable system maintenance. In this book the author used a new technology for on-site withstand tests and partial discharge measurement of XLPE underground power cable system.In this book two methods of testing are presented ,power frequency test and variable frequency (20-300 Hz)test. 140 pp. Englisch. Codice articolo 9783844397994
Quantità: 2 disponibili
Da: moluna, Greven, Germania
Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Gouda OssamaDr.Ossama El-Sayed Gouda is the professor of electrical Power engineering and high voltage in the Dept.of Electrical power,Faculty of Engineering,Cairo University since 1993.He conducted more than 110 papers in the fie. Codice articolo 5477267
Quantità: Più di 20 disponibili
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germania
Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -The use of XLPE insulation for high voltage and extra high voltage power cables is increasing. The new cable systems are installed in the field and inaccurate assembling of cable accessories could result in the precence of deffects.The after laying test is performed in the new cable system to check the quality of cable system installation.Also partial discharge test is usually carried out after cable system maintenance. In this book the author used a new technology for on-site withstand tests and partial discharge measurement of XLPE underground power cable system.In this book two methods of testing are presented ,power frequency test and variable frequency (20-300 Hz)test.Books on Demand GmbH, Überseering 33, 22297 Hamburg 140 pp. Englisch. Codice articolo 9783844397994
Quantità: 1 disponibili
Da: AHA-BUCH GmbH, Einbeck, Germania
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The use of XLPE insulation for high voltage and extra high voltage power cables is increasing. The new cable systems are installed in the field and inaccurate assembling of cable accessories could result in the precence of deffects.The after laying test is performed in the new cable system to check the quality of cable system installation.Also partial discharge test is usually carried out after cable system maintenance. In this book the author used a new technology for on-site withstand tests and partial discharge measurement of XLPE underground power cable system.In this book two methods of testing are presented ,power frequency test and variable frequency (20-300 Hz)test. Codice articolo 9783844397994
Quantità: 1 disponibili
Da: preigu, Osnabrück, Germania
Taschenbuch. Condizione: Neu. Partial Discharge Testing of XLPE Underground Cables Insulation | Partaage Discharge Testing of High Voltage Underground XLPE Power Cables On-Site by Using New Technology | Ossama Gouda (u. a.) | Taschenbuch | 140 S. | Englisch | 2011 | LAP LAMBERT Academic Publishing | EAN 9783844397994 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. Codice articolo 107007231
Quantità: 5 disponibili