Many methods are used for measuring and defining the presence of Parkinson's disease. One important aspect of the disease is gait disturbance, which can be discovered in the early stages of the disease. This disturbance can be measured using three dimensional accelerometers, which are present in the Shimmer device. These devices are light weighted wireless sensor nodes which can be easily mounted on the patient's limbs. Data captured by the device can be streamed to a computer for real-time processing. The Matlab algorithms for step detection are converted to C++ code so they can be used in the EyesWeb environment. Whereas Matlab code can only serve post-processing, the Shimmer's Bluetooth datastream can now be processed in real-time, since the EyesWeb environment supports real-time execution. Hence the Visual Studio environment is needed to design the algorithms into C++ based EyesWeb blocks. This real-time detection algorithm can be applied easily in small and inexpensive lab environments to calculate and obtain the Parkinson's disease severity parameters. Hereby conclusions can be made to prevent the progress of the disease and to treat Parkinson's disorder in early stages.
Le informazioni nella sezione "Riassunto" possono far riferimento a edizioni diverse di questo titolo.
Wouter and Jonas were both students industrial engineering, Wouter with emphasis on IT and Jonas on Electronics. They graduated with distinction. Three and a half years of this education was performed in their home university in Ghent (Belgium). This master's thesis was written in Karlskrona (Sweden) on an abroad student program for half a year.
Le informazioni nella sezione "Su questo libro" possono far riferimento a edizioni diverse di questo titolo.
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germania
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Many methods are used for measuring and defining the presence of Parkinson's disease. One important aspect of the disease is gait disturbance, which can be discovered in the early stages of the disease. This disturbance can be measured using three dimensional accelerometers, which are present in the Shimmer device. These devices are light weighted wireless sensor nodes which can be easily mounted on the patient's limbs. Data captured by the device can be streamed to a computer for real-time processing. The Matlab algorithms for step detection are converted to C++ code so they can be used in the EyesWeb environment. Whereas Matlab code can only serve post-processing, the Shimmer's Bluetooth datastream can now be processed in real-time, since the EyesWeb environment supports real-time execution. Hence the Visual Studio environment is needed to design the algorithms into C++ based EyesWeb blocks. This real-time detection algorithm can be applied easily in small and inexpensive lab environments to calculate and obtain the Parkinson's disease severity parameters. Hereby conclusions can be made to prevent the progress of the disease and to treat Parkinson's disorder in early stages. 96 pp. Englisch. Codice articolo 9783846591673
Quantità: 2 disponibili
Da: Books Puddle, New York, NY, U.S.A.
Condizione: New. pp. 96. Codice articolo 2698160961
Quantità: 4 disponibili
Da: Majestic Books, Hounslow, Regno Unito
Condizione: New. Print on Demand pp. 96 2:B&W 6 x 9 in or 229 x 152 mm Perfect Bound on Creme w/Gloss Lam. Codice articolo 95317662
Quantità: 4 disponibili
Da: Biblios, Frankfurt am main, HESSE, Germania
Condizione: New. PRINT ON DEMAND pp. 96. Codice articolo 1898160971
Quantità: 4 disponibili
Da: moluna, Greven, Germania
Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Speybrouck WouterWouter and Jonas were both students industrial engineering, Wouter with emphasis on IT and Jonas on Electronics. They graduated with distinction. Three and a half years of this education was performed in their home u. Codice articolo 5501780
Quantità: Più di 20 disponibili
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germania
Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Many methods are used for measuring and defining the presence of Parkinson's disease. One important aspect of the disease is gait disturbance, which can be discovered in the early stages of the disease. This disturbance can be measured using three dimensional accelerometers, which are present in the Shimmer device. These devices are light weighted wireless sensor nodes which can be easily mounted on the patient's limbs. Data captured by the device can be streamed to a computer for real-time processing. The Matlab algorithms for step detection are converted to C++ code so they can be used in the EyesWeb environment. Whereas Matlab code can only serve post-processing, the Shimmer's Bluetooth datastream can now be processed in real-time, since the EyesWeb environment supports real-time execution. Hence the Visual Studio environment is needed to design the algorithms into C++ based EyesWeb blocks. This real-time detection algorithm can be applied easily in small and inexpensive lab environments to calculate and obtain the Parkinson's disease severity parameters. Hereby conclusions can be made to prevent the progress of the disease and to treat Parkinson's disorder in early stages.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 96 pp. Englisch. Codice articolo 9783846591673
Quantità: 1 disponibili
Da: AHA-BUCH GmbH, Einbeck, Germania
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Many methods are used for measuring and defining the presence of Parkinson's disease. One important aspect of the disease is gait disturbance, which can be discovered in the early stages of the disease. This disturbance can be measured using three dimensional accelerometers, which are present in the Shimmer device. These devices are light weighted wireless sensor nodes which can be easily mounted on the patient's limbs. Data captured by the device can be streamed to a computer for real-time processing. The Matlab algorithms for step detection are converted to C++ code so they can be used in the EyesWeb environment. Whereas Matlab code can only serve post-processing, the Shimmer's Bluetooth datastream can now be processed in real-time, since the EyesWeb environment supports real-time execution. Hence the Visual Studio environment is needed to design the algorithms into C++ based EyesWeb blocks. This real-time detection algorithm can be applied easily in small and inexpensive lab environments to calculate and obtain the Parkinson's disease severity parameters. Hereby conclusions can be made to prevent the progress of the disease and to treat Parkinson's disorder in early stages. Codice articolo 9783846591673
Quantità: 1 disponibili
Da: preigu, Osnabrück, Germania
Taschenbuch. Condizione: Neu. Implementing real-time step detection algorithm in EyesWeb environment | Monitoring the gait of Parkinson's patients | Wouter Speybrouck (u. a.) | Taschenbuch | 96 S. | Englisch | 2011 | LAP LAMBERT Academic Publishing | EAN 9783846591673 | Verantwortliche Person für die EU: BoD - Books on Demand, In de Tarpen 42, 22848 Norderstedt, info[at]bod[dot]de | Anbieter: preigu. Codice articolo 106671828
Quantità: 5 disponibili