In high voltage (HV) electrical power systems; varieties of materials (solid, liquid and gaseous) are used for insulation purpose to protect the early failure in High Voltage power equipment. Most of the insulating materials are not perfect in all respect and contain some impurities. The presence of air bubble is one of such impurities in insulating materials which is highly undesirable. Insulation of the HV power equipment gradually degrades due to the cumulative effect of electrical, chemical and thermal stress and aging. Due to the high voltage stress, the weak zone inside the insulator causes partial discharge (PD).This deteriorates the insulator. In this paper, an electrical circuit model of the solid insulator with void is used to study the PD activity leading to breakdown inside the insulator. Among the models (namely the capacitive model and induced charge concept model), the capacitive model is adopted in present work. The Simulink capacitive model implemented, effectively demonstrates the partial discharge process. The model is used to study and demonstrate the effect of the permittivity of cavity/impurity and breakdown inception voltage level of the impurity.
Le informazioni nella sezione "Riassunto" possono far riferimento a edizioni diverse di questo titolo.
Da: PBShop.store US, Wood Dale, IL, U.S.A.
PAP. Condizione: New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Codice articolo L0-9786139452811
Quantità: Più di 20 disponibili
Da: California Books, Miami, FL, U.S.A.
Condizione: New. Codice articolo I-9786139452811
Quantità: Più di 20 disponibili
Da: PBShop.store UK, Fairford, GLOS, Regno Unito
PAP. Condizione: New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Codice articolo L0-9786139452811
Quantità: Più di 20 disponibili
Da: Ria Christie Collections, Uxbridge, Regno Unito
Condizione: New. In English. Codice articolo ria9786139452811_new
Quantità: Più di 20 disponibili
Da: Chiron Media, Wallingford, Regno Unito
PF. Condizione: New. Codice articolo 6666-IUK-9786139452811
Quantità: 10 disponibili
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germania
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -In high voltage (HV) electrical power systems; varieties of materials (solid, liquid and gaseous) are used for insulation purpose to protect the early failure in High Voltage power equipment. Most of the insulating materials are not perfect in all respect and contain some impurities. The presence of air bubble is one of such impurities in insulating materials which is highly undesirable. Insulation of the HV power equipment gradually degrades due to the cumulative effect of electrical, chemical and thermal stress and aging. Due to the high voltage stress, the weak zone inside the insulator causes partial discharge (PD).This deteriorates the insulator. In this paper, an electrical circuit model of the solid insulator with void is used to study the PD activity leading to breakdown inside the insulator. Among the models (namely the capacitive model and induced charge concept model), the capacitive model is adopted in present work. The Simulink capacitive model implemented, effectively demonstrates the partial discharge process. The model is used to study and demonstrate the effect of the permittivity of cavity/impurity and breakdown inception voltage level of the impurity. 52 pp. Englisch. Codice articolo 9786139452811
Quantità: 1 disponibili
Da: Books Puddle, Woodside, NY, U.S.A.
Condizione: New. Codice articolo 26388021116
Quantità: 4 disponibili
Da: AHA-BUCH GmbH, Einbeck, Germania
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - In high voltage (HV) electrical power systems; varieties of materials (solid, liquid and gaseous) are used for insulation purpose to protect the early failure in High Voltage power equipment. Most of the insulating materials are not perfect in all respect and contain some impurities. The presence of air bubble is one of such impurities in insulating materials which is highly undesirable. Insulation of the HV power equipment gradually degrades due to the cumulative effect of electrical, chemical and thermal stress and aging. Due to the high voltage stress, the weak zone inside the insulator causes partial discharge (PD).This deteriorates the insulator. In this paper, an electrical circuit model of the solid insulator with void is used to study the PD activity leading to breakdown inside the insulator. Among the models (namely the capacitive model and induced charge concept model), the capacitive model is adopted in present work. The Simulink capacitive model implemented, effectively demonstrates the partial discharge process. The model is used to study and demonstrate the effect of the permittivity of cavity/impurity and breakdown inception voltage level of the impurity. Codice articolo 9786139452811
Quantità: 1 disponibili
Da: Majestic Books, Hounslow, Regno Unito
Condizione: New. Print on Demand. Codice articolo 391578787
Quantità: 4 disponibili
Da: Biblios, Frankfurt am main, HESSE, Germania
Condizione: New. PRINT ON DEMAND. Codice articolo 18388021110
Quantità: 4 disponibili