The major problem in grid-connected power transmission and distribution networks is the quality issues due to the unbalance loads. The power quality issues related to the current and voltage-based issues generated at the PCC (point of common coupling). Some of the current issues related to reactive power extraction, poor zero voltage regulation, harmonic currents, undesired neutral current, and low power factor. Several D-STATCOM compensation techniques have been introduced for the compensation of power quality issues in the three-phase and four-wire system. The proposed work focuses on D-STATCOM soft computing techniques such as widrow-Hoff least mean square, vectorial filter, discrete adaptive filter, and quasi-Newton control algorithms. The proposed algorithms controlled the switching pulses to drive the voltage source converter (VSC) section in the network thereby mitigating the D-STATCOM reactive power generation in the grid-connected photovoltaic (PV) system. The soft computing techniques have maintained constant DC bus coupling capacitor voltage and common voltage maintaining unity power factor, zero voltage regulation for linear and non-linear loads.
Le informazioni nella sezione "Riassunto" possono far riferimento a edizioni diverse di questo titolo.
I tuoi diritti di garanzia legale: Ogni consumatore nell'UE beneficia di almeno 2 anni di garanzia legale per qualsiasi bene di consumo venduto nell'UE. Scopri di più
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germania
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The major problem in grid-connected power transmission and distribution networks is the quality issues due to the unbalance loads. The power quality issues related to the current and voltage-based issues generated at the PCC (point of common coupling). Some of the current issues related to reactive power extraction, poor zero voltage regulation, harmonic currents, undesired neutral current, and low power factor. Several D-STATCOM compensation techniques have been introduced for the compensation of power quality issues in the three-phase and four-wire system. The proposed work focuses on D-STATCOM soft computing techniques such as widrow-Hoff least mean square, vectorial filter, discrete adaptive filter, and quasi-Newton control algorithms. The proposed algorithms controlled the switching pulses to drive the voltage source converter (VSC) section in the network thereby mitigating the D-STATCOM reactive power generation in the grid-connected photovoltaic (PV) system. The soft computing techniques have maintained constant DC bus coupling capacitor voltage and common voltage maintaining unity power factor, zero voltage regulation for linear and non-linear loads. 172 pp. Englisch. Codice articolo 9786203869255
Quantità: 2 disponibili
Da: moluna, Greven, Germania
Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Pragathi BellamkondaBellamkonda Pragathi working as an Associate Professor at MIC college of technology. I have received a doctoral degree from KL University. I have published papers in Scopus, ESCI and SCI.The major problem in g. Codice articolo 498116796
Quantità: Più di 20 disponibili
Da: AHA-BUCH GmbH, Einbeck, Germania
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The major problem in grid-connected power transmission and distribution networks is the quality issues due to the unbalance loads. The power quality issues related to the current and voltage-based issues generated at the PCC (point of common coupling). Some of the current issues related to reactive power extraction, poor zero voltage regulation, harmonic currents, undesired neutral current, and low power factor. Several D-STATCOM compensation techniques have been introduced for the compensation of power quality issues in the three-phase and four-wire system. The proposed work focuses on D-STATCOM soft computing techniques such as widrow-Hoff least mean square, vectorial filter, discrete adaptive filter, and quasi-Newton control algorithms. The proposed algorithms controlled the switching pulses to drive the voltage source converter (VSC) section in the network thereby mitigating the D-STATCOM reactive power generation in the grid-connected photovoltaic (PV) system. The soft computing techniques have maintained constant DC bus coupling capacitor voltage and common voltage maintaining unity power factor, zero voltage regulation for linear and non-linear loads. Codice articolo 9786203869255
Quantità: 1 disponibili
Da: Books Puddle, Woodside, NY, U.S.A.
Condizione: New. Codice articolo 26401141132
Quantità: 4 disponibili
Da: preigu, Osnabrück, Germania
Taschenbuch. Condizione: Neu. Mitigation of Power quality issues for the PV systems using FPGA | Power Quality Assessment of Grid-Connected PV System | Bellamkonda Pragathi (u. a.) | Taschenbuch | Englisch | 2021 | LAP LAMBERT Academic Publishing | EAN 9786203869255 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. Codice articolo 120476717
Quantità: 5 disponibili
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germania
Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -The major problem in grid-connected power transmission and distribution networks is the quality issues due to the unbalance loads. The power quality issues related to the current and voltage-based issues generated at the PCC (point of common coupling). Some of the current issues related to reactive power extraction, poor zero voltage regulation, harmonic currents, undesired neutral current, and low power factor. Several D-STATCOM compensation techniques have been introduced for the compensation of power quality issues in the three-phase and four-wire system. The proposed work focuses on D-STATCOM soft computing techniques such as widrow-Hoff least mean square, vectorial filter, discrete adaptive filter, and quasi-Newton control algorithms. The proposed algorithms controlled the switching pulses to drive the voltage source converter (VSC) section in the network thereby mitigating the D-STATCOM reactive power generation in the grid-connected photovoltaic (PV) system. The soft computing techniques have maintained constant DC bus coupling capacitor voltage and common voltage maintaining unity power factor, zero voltage regulation for linear and non-linear loads.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 172 pp. Englisch. Codice articolo 9786203869255
Quantità: 1 disponibili
Da: Majestic Books, Hounslow, Regno Unito
Condizione: New. Print on Demand. Codice articolo 396317267
Quantità: 4 disponibili
Da: Biblios, Frankfurt am main, HESSE, Germania
Condizione: New. PRINT ON DEMAND. Codice articolo 18401141126
Quantità: 4 disponibili