A rapid and precise Reverse Phase High Performance Liquid Chromatographic method has been developed for the validated of Piroxicam, in its pure form as well as in tablet dosage form. Chromatography was carried out on X-terra C18 (4.6 x 250mm, 5μm) column using a mixture of Acetonitrile and Water (40:60 v/v) as the mobile phase at a flow rate of 0.9ml/min, the detection was carried out at 227nm. The retention time of the Piroxicam was 5.430 ±0.02min respectively. The method produce linear responses in the concentration range of 10-50mg/ml of Piroxicam.The method precision for the determination of assay was below 2.0%RSD. The method is useful in the quality control of bulk and pharmaceutical formulations.
Le informazioni nella sezione "Riassunto" possono far riferimento a edizioni diverse di questo titolo.
EUR 9,70 per la spedizione da Germania a Italia
Destinazione, tempi e costiDa: moluna, Greven, Germania
Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Choudhury TirthankarTirthankar Choudhury completed: B. Pharm, M.Pharm, PhD, F.I.C.Teaching, has research experience of 12 years 8 Months. Present Designation: Professor, H.O.D. (Pharmaceutical Chemistry) Award & Achievement:-1) Dis. Codice articolo 498117128
Quantità: Più di 20 disponibili
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germania
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -A rapid and precise Reverse Phase High Performance Liquid Chromatographic method has been developed for the validated of Piroxicam, in its pure form as well as in tablet dosage form. Chromatography was carried out on X-terra C18 (4.6 x 250mm, 5mim) column using a mixture of Acetonitrile and Water (40:60 v/v) as the mobile phase at a flow rate of 0.9ml/min, the detection was carried out at 227nm. The retention time of the Piroxicam was 5.430 ±0.02min respectively. The method produce linear responses in the concentration range of 10-50mg/ml of Piroxicam.The method precision for the determination of assay was below 2.0%RSD. The method is useful in the quality control of bulk and pharmaceutical formulations. 112 pp. Englisch. Codice articolo 9786204184012
Quantità: 2 disponibili
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germania
Taschenbuch. Condizione: Neu. Neuware -A rapid and precise Reverse Phase High Performance Liquid Chromatographic method has been developed for the validated of Piroxicam, in its pure form as well as in tablet dosage form. Chromatography was carried out on X-terra C18 (4.6 x 250mm, 5¿m) column using a mixture of Acetonitrile and Water (40:60 v/v) as the mobile phase at a flow rate of 0.9ml/min, the detection was carried out at 227nm. The retention time of the Piroxicam was 5.430 ±0.02min respectively. The method produce linear responses in the concentration range of 10-50mg/ml of Piroxicam.The method precision for the determination of assay was below 2.0%RSD. The method is useful in the quality control of bulk and pharmaceutical formulations.Books on Demand GmbH, Überseering 33, 22297 Hamburg 112 pp. Englisch. Codice articolo 9786204184012
Quantità: 2 disponibili
Da: AHA-BUCH GmbH, Einbeck, Germania
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - A rapid and precise Reverse Phase High Performance Liquid Chromatographic method has been developed for the validated of Piroxicam, in its pure form as well as in tablet dosage form. Chromatography was carried out on X-terra C18 (4.6 x 250mm, 5mim) column using a mixture of Acetonitrile and Water (40:60 v/v) as the mobile phase at a flow rate of 0.9ml/min, the detection was carried out at 227nm. The retention time of the Piroxicam was 5.430 ±0.02min respectively. The method produce linear responses in the concentration range of 10-50mg/ml of Piroxicam.The method precision for the determination of assay was below 2.0%RSD. The method is useful in the quality control of bulk and pharmaceutical formulations. Codice articolo 9786204184012
Quantità: 1 disponibili
Da: Books Puddle, New York, NY, U.S.A.
Condizione: New. Codice articolo 26397311240
Quantità: 4 disponibili
Da: Majestic Books, Hounslow, Regno Unito
Condizione: New. Print on Demand. Codice articolo 400147159
Quantità: 4 disponibili
Da: Biblios, Frankfurt am main, HESSE, Germania
Condizione: New. PRINT ON DEMAND. Codice articolo 18397311234