Aaron d quastel (6 risultati)

- Brossura
Da: preigu, Osnabrück, Germaniapreigu
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 43,30
EUR 70,00 spedizioneSpedito da Germania a U.S.A.Quantità: 5 disponibili
Taschenbuch. Condizione: Neu. Impurity Effects on Deuterium Retention in Single Crystal Tungsten | Plasma-Surface Interaction, Plasma Facing Materials in Fusion Reactors - Fusion Research | Aaron D. Quastel | Taschenbuch | 88 S. | Englisch | 2010 | LAP LAMBERT Academic Publishing | EAN 9783838309583 | Verantwortliche Person für…die EU: BoD - Books on Demand, In de Tarpen 42, 22848 Norderstedt, info[at]bod[dot]de | Anbieter: preigu.

- Brossura
Da: Mispah books, Redhill, SURRE, Regno UnitoMispah books
Contatta il venditoreVenditore con 4 stelleCondizione: Nuovo
EUR 187,43
EUR 28,98 spedizioneSpedito da Regno Unito a U.S.A.Quantità: 1 disponibili
paperback. Condizione: New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book.

- Brossura
- Print on Demand
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermaniaBuchWeltWeit Ludwig Meier e.K.
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 49,00
EUR 23,00 spedizioneSpedito da Germania a U.S.A.Quantità: 2 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Tungsten will be used in the divertor section of the ITER fusion reactor. The divertor is exposed to fluxes of deuterium, tritium, helium and other plasma nuclei. The role of impurities in the retention of deuterium in single cryst…al tungsten at room temperature has been investigated. To avoid the effects of air exposure, the D implantation and the subsequent D retention measurement using TDS was performed in the same vacuum chamber without breaking vacuum. For fluences of 1x10^23 D/m^2, desorption peaks were observed, at ~400 K and at ~600 K. The use of liquid nitrogen cooling of the ion beam aperture led to a reduction of the background gas impurities in the vacuum test chamber, which almost completely eliminated the post-irradiation TDS peak at 400 K. Reduction of these gas impurities has led to a reduction in the total deuterium retention. Furthermore, implanted deuterium in the W specimens was released when the vacuum system was gently baked before TDS, resulting in an additional reduction in the total amount of retained D. It was also found that post- implantation time delay before performing TDS lead to a significant loss of the implanted deuterium. 88 pp. Englisch.

- Brossura
- Print on Demand
Da: moluna, Greven, Germaniamoluna
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 41,05
EUR 48,99 spedizioneSpedito da Germania a U.S.A.Quantità: Più di 20 disponibili
Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Quastel Aaron D.Aaron is Mechanical Engineering graduate from the University of Manitoba. He also holds a MASc degree in Fusion energy research from the University of Toronto. He worked at AECL and is…pursuing a PhD degree in Nuclear.

- Brossura
- Print on Demand
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germaniabuchversandmimpf2000
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 49,00
EUR 60,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Tungsten will be used in the divertor section of the ITER fusion reactor. The divertor is exposed to fluxes of deuterium, tritium, helium and other plasma nuclei. The role of impurities in the retention of deuterium in single crystal t…ungsten at room temperature has been investigated. To avoid the effects of air exposure, the D implantation and the subsequent D retention measurement using TDS was performed in the same vacuum chamber without breaking vacuum. For fluences of 1x10^23 D/m^2, desorption peaks were observed, at ~400 K and at ~600 K. The use of liquid nitrogen cooling of the ion beam aperture led to a reduction of the background gas impurities in the vacuum test chamber, which almost completely eliminated the post-irradiation TDS peak at 400 K. Reduction of these gas impurities has led to a reduction in the total deuterium retention. Furthermore, implanted deuterium in the W specimens was released when the vacuum system was gently baked before TDS, resulting in an additional reduction in the total amount of retained D. It was also found that post- implantation time delay before performing TDS lead to a significant loss of the implanted deuterium.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 88 pp. Englisch.

- Brossura
- Print on Demand
Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 49,59
EUR 60,75 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibili
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Tungsten will be used in the divertor section of the ITER fusion reactor. The divertor is exposed to fluxes of deuterium, tritium, helium and other plasma nuclei. The role of impurities in the retention of deuterium in single crystal tu…ngsten at room temperature has been investigated. To avoid the effects of air exposure, the D implantation and the subsequent D retention measurement using TDS was performed in the same vacuum chamber without breaking vacuum. For fluences of 1x10^23 D/m^2, desorption peaks were observed, at ~400 K and at ~600 K. The use of liquid nitrogen cooling of the ion beam aperture led to a reduction of the background gas impurities in the vacuum test chamber, which almost completely eliminated the post-irradiation TDS peak at 400 K. Reduction of these gas impurities has led to a reduction in the total deuterium retention. Furthermore, implanted deuterium in the W specimens was released when the vacuum system was gently baked before TDS, resulting in an additional reduction in the total amount of retained D. It was also found that post- implantation time delay before performing TDS lead to a significant loss of the implanted deuterium.