Ansari k b mohd umar (6 risultati)

- Brossura
Da: Revaluation Books, Exeter, Regno UnitoRevaluation Books
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 99,15
EUR 11,69 spedizioneSpedito da Regno Unito a U.S.A.Quantità: 1 disponibili
Paperback. Condizione: Brand New. 108 pages. 8.66x5.91x0.25 inches. In Stock.

- Brossura
Da: preigu, Osnabrück, Germaniapreigu
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 47,90
EUR 70,00 spedizioneSpedito da Germania a U.S.A.Quantità: 5 disponibili
Taschenbuch. Condizione: Neu. STATCOM for Improved Dynamic Performance of WF connected in Power Grid | Description & Simulation with and without STATCOM for Improved Dynamic Performance of Wind Farms Connected in Power Grid | K. B. Mohd. Umar Ansari | Taschenbuch | 108 S. | Englisch | 2018 | LAP LAMBERT Academic Publishing | EAN… 9786139886562 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.

- Brossura
- Print on Demand
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermaniaBuchWeltWeit Ludwig Meier e.K.
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 54,90
EUR 23,00 spedizioneSpedito da Germania a U.S.A.Quantità: 2 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The applicability of a STATCOM in wind farms has been investigated and the results indicate that it is able to supply reactive power requirements of the wind farm under various operating conditions, thereby improving the steady-sta…te stability limit of the network. In this work, the wind turbine modelled is a SCIG that is an induction machine which requires reactive power compensation during grid side disturbances. An appropriately sized STATCOM can provide the necessary reactive power compensation when connected to grid. Also, a higher rating STATCOM can be used for efficient voltage control and improved reliability in grid connected wind farm. The additional voltage/var support provided by an external device such as a STATCOM can significantly improve the wind turbines fault recovery by more quickly restoring voltage characteristics. The extent to which a STATCOM can provide support depends on its rating. The higher the rating, the more support provided. The dynamic performance of wind farms in a power grid is improved by the application of a STATCOM. The STATCOM helps to provide better voltage characteristics during faults like phase-phase to ground fault, three phase faults. 108 pp. Englisch.

- Brossura
- Print on Demand
Da: moluna, Greven, Germaniamoluna
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 45,45
EUR 48,99 spedizioneSpedito da Germania a U.S.A.Quantità: Più di 20 disponibili
Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Ansari K. B. Mohd. UmarEr. K.B.Mohd. Umar Ansari was born in Port Blair,A&N Islands ,India, received B.E. Degree in EEE from SPEC affiliated to Anna University,Chennai,T.N.,worked as Lecturer in MIIT,M…eerut. Then received MTech. Degr.

- Brossura
- Print on Demand
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germaniabuchversandmimpf2000
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 54,90
EUR 60,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -The applicability of a STATCOM in wind farms has been investigated and the results indicate that it is able to supply reactive power requirements of the wind farm under various operating conditions, thereby improving the steady-state s…tability limit of the network. In this work, the wind turbine modelled is a SCIG that is an induction machine which requires reactive power compensation during grid side disturbances. An appropriately sized STATCOM can provide the necessary reactive power compensation when connected to grid. Also, a higher rating STATCOM can be used for efficient voltage control and improved reliability in grid connected wind farm. The additional voltage/var support provided by an external device such as a STATCOM can significantly improve the wind turbines fault recovery by more quickly restoring voltage characteristics. The extent to which a STATCOM can provide support depends on its rating. The higher the rating, the more support provided. The dynamic performance of wind farms in a power grid is improved by the application of a STATCOM. The STATCOM helps to provide better voltage characteristics during faults like phase-phase to ground fault, three phase faults.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 108 pp. Englisch.

- Brossura
- Print on Demand
Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 55,56
EUR 60,90 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibili
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The applicability of a STATCOM in wind farms has been investigated and the results indicate that it is able to supply reactive power requirements of the wind farm under various operating conditions, thereby improving the steady-state st…ability limit of the network. In this work, the wind turbine modelled is a SCIG that is an induction machine which requires reactive power compensation during grid side disturbances. An appropriately sized STATCOM can provide the necessary reactive power compensation when connected to grid. Also, a higher rating STATCOM can be used for efficient voltage control and improved reliability in grid connected wind farm. The additional voltage/var support provided by an external device such as a STATCOM can significantly improve the wind turbines fault recovery by more quickly restoring voltage characteristics. The extent to which a STATCOM can provide support depends on its rating. The higher the rating, the more support provided. The dynamic performance of wind farms in a power grid is improved by the application of a STATCOM. The STATCOM helps to provide better voltage characteristics during faults like phase-phase to ground fault, three phase faults.