Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing, 2019
ISBN 10: 6139444861 ISBN 13: 9786139444861
Da: preigu, Osnabrück, Germania
EUR 36,25
Quantità: 5 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. Optimal placement of Capacitor Banks in Transmission Networks | Application of capacitor banks in minimizing transmission line losses | Debashish Bhowmik (u. a.) | Taschenbuch | 80 S. | Englisch | 2019 | LAP LAMBERT Academic Publishing | EAN 9786139444861 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing Feb 2019, 2019
ISBN 10: 6139444861 ISBN 13: 9786139444861
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germania
EUR 39,90
Quantità: 2 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -In a power system it is very essential to maintain the voltage within specified limitand to deliver active power through transmission lines in which reactive power plays a major role. It is also essential to retain the voltage and to deliver active power through transmission lines. This book presents a method for optimal sizing andlocation of capacitors banks in a system for improving the voltage profile and minimizing system losses. The most important part of the work is to determine the size of the capacitor to be placed at the bus. Secondly, determination of the location to capacitor in the system is another vibrant task. The calculation of power loss indices (PLI) are done after knowing the size of capacitors. Then the PLI and per unit nodal voltage are given as input to the fuzzy expert system to determine the suitability index which will decide the most suitable place for capacitor placement. Newton-Raphson method for load flow analysis is carried out to find the voltages at each node and the system losses. The overall reliability and accuracy of proposed method is validated by testing on three different IEEE test bus systems. 80 pp. Englisch.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing Feb 2019, 2019
ISBN 10: 6139444861 ISBN 13: 9786139444861
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germania
EUR 39,90
Quantità: 1 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -In a power system it is very essential to maintain the voltage within specified limitand to deliver active power through transmission lines in which reactive power plays a major role. It is also essential to retain the voltage and to deliver active power through transmission lines. This book presents a method for optimal sizing andlocation of capacitors banks in a system for improving the voltage profile and minimizing system losses. The most important part of the work is to determine the size of the capacitor to be placed at the bus. Secondly, determination of the location to capacitor in the system is another vibrant task. The calculation of power loss indices (PLI) are done after knowing the size of capacitors. Then the PLI and per unit nodal voltage are given as input to the fuzzy expert system to determine the suitability index which will decide the most suitable place for capacitor placement. Newton-Raphson method for load flow analysis is carried out to find the voltages at each node and the system losses. The overall reliability and accuracy of proposed method is validated by testing on three different IEEE test bus systems.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 80 pp. Englisch.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing, 2019
ISBN 10: 6139444861 ISBN 13: 9786139444861
Da: AHA-BUCH GmbH, Einbeck, Germania
EUR 40,89
Quantità: 1 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - In a power system it is very essential to maintain the voltage within specified limitand to deliver active power through transmission lines in which reactive power plays a major role. It is also essential to retain the voltage and to deliver active power through transmission lines. This book presents a method for optimal sizing andlocation of capacitors banks in a system for improving the voltage profile and minimizing system losses. The most important part of the work is to determine the size of the capacitor to be placed at the bus. Secondly, determination of the location to capacitor in the system is another vibrant task. The calculation of power loss indices (PLI) are done after knowing the size of capacitors. Then the PLI and per unit nodal voltage are given as input to the fuzzy expert system to determine the suitability index which will decide the most suitable place for capacitor placement. Newton-Raphson method for load flow analysis is carried out to find the voltages at each node and the system losses. The overall reliability and accuracy of proposed method is validated by testing on three different IEEE test bus systems.