Giri markanday (6 risultati)

Autore: 
Perfeziona con la Ricerca avanzata

Perfeziona la tua ricerca

  • Libri (6)

  • Nuovo (6)

a

Fascia di prezzo personalizzata (EUR)

a

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing, 2020

    6200326339 / 9786200326331

    • Brossura

    Da: preigu, Osnabrück, Germaniapreigu

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 61,05

    EUR 70,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 5 disponibili

    Taschenbuch. Condizione: Neu. Response Spectrum Analysis | Response Spectrum Analysis in Flat Slab Multistorey Building for Earthquake Zone IV | Markanday Giri (u. a.) | Taschenbuch | 176 S. | Englisch | 2020 | LAP LAMBERT Academic Publishing | EAN 9786200326331 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. …

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing, 2020

    6200326339 / 9786200326331

    • Brossura

    Da: Mispah books, Redhill, SURRE, Regno UnitoMispah books

    Venditore con 4 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 423,88

    EUR 29,65 spedizione 
    Spedito da Regno Unito a U.S.A.

    Quantità: 1 disponibile

    paperback. Condizione: New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book.

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing Jan 2020, 2020

    6200326339 / 9786200326331

    • Brossura
    • Print on Demand

    Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermaniaBuchWeltWeit Ludwig Meier e.K.

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 71,90

    EUR 23,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 2 disponibili

    Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The necessity of large head room are now the essential point of view for any architecture and for that, the only way to solve this as per structural point of view is to be provide flat slab. The elimination of beam could show the drastic effect in different component of the structure. It has been examine from various findings that the stresses generated in the flat slab analysis, its intensity should lessen in order to provide stability to the structure. For this, four cases have been taken viz., simple flat slab providing shear wall at lift area, simple flat slab providing shear wall at lift area and at maximum stress location, flat slab with drop providing shear wall at lift area and flat slab with drop providing shear wall at lift area and at maximum stress location on G+11 Multistoried residential building located at Seismic Zone IV. Using response spectrum method with the help of analysis and design tool STAAD Pro V8i, to evaluate analysis parameters such as Nodal Displacement, Shear forces in column, Compressive and tensile stresses, storey drift, von mis stress along with principle stress values. The prime case is obtained in this work is building case B2. 176 pp. Englisch.…

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing, 2020

    6200326339 / 9786200326331

    • Brossura
    • Print on Demand

    Da: moluna, Greven, Germaniamoluna

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 58,12

    EUR 48,99 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: Più di 20 disponibili

    Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Giri MarkandayI am Dr. Kundan Meshram, Associate Professor and Head, Department of Civil Engineering, Oriental University, Indore(M.P.)The necessity of large head room are now the essential point of view for any architecture and .…

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing, 2020

    6200326339 / 9786200326331

    • Brossura
    • Print on Demand

    Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 79,37

    EUR 35,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 1 disponibile

    Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The necessity of large head room are now the essential point of view for any architecture and for that, the only way to solve this as per structural point of view is to be provide flat slab. The elimination of beam could show the drastic effect in different component of the structure. It has been examine from various findings that the stresses generated in the flat slab analysis, its intensity should lessen in order to provide stability to the structure. For this, four cases have been taken viz., simple flat slab providing shear wall at lift area, simple flat slab providing shear wall at lift area and at maximum stress location, flat slab with drop providing shear wall at lift area and flat slab with drop providing shear wall at lift area and at maximum stress location on G+11 Multistoried residential building located at Seismic Zone IV. Using response spectrum method with the help of analysis and design tool STAAD Pro V8i, to evaluate analysis parameters such as Nodal Displacement, Shear forces in column, Compressive and tensile stresses, storey drift, von mis stress along with principle stress values. The prime case is obtained in this work is building case B2.…

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing Jan 2020, 2020

    6200326339 / 9786200326331

    • Brossura
    • Print on Demand

    Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germaniabuchversandmimpf2000

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 71,90

    EUR 60,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 1 disponibile

    Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -The necessity of large head room are now the essential point of view for any architecture and for that, the only way to solve this as per structural point of view is to be provide flat slab. The elimination of beam could show the drastic effect in different component of the structure. It has been examine from various findings that the stresses generated in the flat slab analysis, its intensity should lessen in order to provide stability to the structure. For this, four cases have been taken viz., simple flat slab providing shear wall at lift area, simple flat slab providing shear wall at lift area and at maximum stress location, flat slab with drop providing shear wall at lift area and flat slab with drop providing shear wall at lift area and at maximum stress location on G+11 Multistoried residential building located at Seismic Zone IV. Using response spectrum method with the help of analysis and design tool STAAD Pro V8i, to evaluate analysis parameters such as Nodal Displacement, Shear forces in column, Compressive and tensile stresses, storey drift, von mis stress along with principle stress values. The prime case is obtained in this work is building case B2.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 176 pp. Englisch.…