Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing, 2020
ISBN 10: 6200326339 ISBN 13: 9786200326331
Da: Mispah books, Redhill, SURRE, Regno Unito
EUR 197,50
Quantità: 1 disponibili
Aggiungi al carrellopaperback. Condizione: New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing Jan 2020, 2020
ISBN 10: 6200326339 ISBN 13: 9786200326331
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germania
EUR 71,90
Quantità: 2 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The necessity of large head room are now the essential point of view for any architecture and for that, the only way to solve this as per structural point of view is to be provide flat slab. The elimination of beam could show the drastic effect in different component of the structure. It has been examine from various findings that the stresses generated in the flat slab analysis, its intensity should lessen in order to provide stability to the structure. For this, four cases have been taken viz., simple flat slab providing shear wall at lift area, simple flat slab providing shear wall at lift area and at maximum stress location, flat slab with drop providing shear wall at lift area and flat slab with drop providing shear wall at lift area and at maximum stress location on G+11 Multistoried residential building located at Seismic Zone IV. Using response spectrum method with the help of analysis and design tool STAAD Pro V8i, to evaluate analysis parameters such as Nodal Displacement, Shear forces in column, Compressive and tensile stresses, storey drift, von mis stress along with principle stress values. The prime case is obtained in this work is building case B2. 176 pp. Englisch.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing, 2020
ISBN 10: 6200326339 ISBN 13: 9786200326331
Da: moluna, Greven, Germania
EUR 58,12
Quantità: Più di 20 disponibili
Aggiungi al carrelloCondizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Giri MarkandayI am Dr. Kundan Meshram, Associate Professor and Head, Department of Civil Engineering, Oriental University, Indore(M.P.)The necessity of large head room are now the essential point of view for any architecture and .
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing Jan 2020, 2020
ISBN 10: 6200326339 ISBN 13: 9786200326331
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germania
EUR 71,90
Quantità: 1 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -The necessity of large head room are now the essential point of view for any architecture and for that, the only way to solve this as per structural point of view is to be provide flat slab. The elimination of beam could show the drastic effect in different component of the structure. It has been examine from various findings that the stresses generated in the flat slab analysis, its intensity should lessen in order to provide stability to the structure. For this, four cases have been taken viz., simple flat slab providing shear wall at lift area, simple flat slab providing shear wall at lift area and at maximum stress location, flat slab with drop providing shear wall at lift area and flat slab with drop providing shear wall at lift area and at maximum stress location on G+11 Multistoried residential building located at Seismic Zone IV. Using response spectrum method with the help of analysis and design tool STAAD Pro V8i, to evaluate analysis parameters such as Nodal Displacement, Shear forces in column, Compressive and tensile stresses, storey drift, von mis stress along with principle stress values. The prime case is obtained in this work is building case B2.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 176 pp. Englisch.
Lingua: Inglese
Editore: LAP LAMBERT Academic Publishing, 2020
ISBN 10: 6200326339 ISBN 13: 9786200326331
Da: AHA-BUCH GmbH, Einbeck, Germania
EUR 72,76
Quantità: 1 disponibili
Aggiungi al carrelloTaschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The necessity of large head room are now the essential point of view for any architecture and for that, the only way to solve this as per structural point of view is to be provide flat slab. The elimination of beam could show the drastic effect in different component of the structure. It has been examine from various findings that the stresses generated in the flat slab analysis, its intensity should lessen in order to provide stability to the structure. For this, four cases have been taken viz., simple flat slab providing shear wall at lift area, simple flat slab providing shear wall at lift area and at maximum stress location, flat slab with drop providing shear wall at lift area and flat slab with drop providing shear wall at lift area and at maximum stress location on G+11 Multistoried residential building located at Seismic Zone IV. Using response spectrum method with the help of analysis and design tool STAAD Pro V8i, to evaluate analysis parameters such as Nodal Displacement, Shear forces in column, Compressive and tensile stresses, storey drift, von mis stress along with principle stress values. The prime case is obtained in this work is building case B2.