Mayur m sevak (4 risultati)

Autore: 
Perfeziona con la Ricerca avanzata

Perfeziona la tua ricerca

  • Libri (4)

  • Nuovo (4)

a

Fascia di prezzo personalizzata (EUR)

a

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing, 2026

    6209922325 / 9786209922329

    • Brossura

    Da: preigu, Osnabrück, Germaniapreigu

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 78,00

    EUR 70,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 5 disponibili

    Taschenbuch. Condizione: Neu. Development of Wearable ECG Recorder | The compression of ECG signals through SVD and implementation on Hardware | Mayur M. Sevak (u. a.) | Taschenbuch | Englisch | 2026 | LAP LAMBERT Academic Publishing | EAN 9786209922329 | Verantwortliche Person für die EU: SIA OmniScriptum Publishing, Brivibas Gatve 197, 1039 RIGA, LETTLAND, customerservice[at]vdm-vsg[dot]de | Anbieter: preigu.…

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing Apr 2026, 2026

    6209922325 / 9786209922329

    • Brossura
    • Print on Demand

    Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermaniaBuchWeltWeit Ludwig Meier e.K.

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 93,90

    EUR 23,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 2 disponibili

    Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware 212 pp. Englisch.

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing, 2026

    6209922325 / 9786209922329

    • Brossura
    • Print on Demand

    Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 99,30

    EUR 35,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 1 disponibile

    Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Heart disease is the leading cause of abnormal mortality, and the rate is rising. Multiple cycles and high-resolution gathering produce a lot of ECG data, which reduces its portability and transmission efficiency. This calls for ECG signal compression. This research aims to compress wired and wirelessly recorded ECG data using Biopac and Bio Radio devices and demonstrate its implementation on aPYNQ-Z2 platform. Its feasibility and effectiveness are investigated. To record ECG signals from two distinct devices-Biopac and Bio Radio-with an ECG lead-1 and lead-2 configuration, a database was made specifically for this purpose. They were utilized to get ECG data from individuals aged 22, 23, 24, 35, 37, and 49. Singular Value Decomposition has been deployed to compress all ECG data on the PYNQZ2 PS Part, which provides a Python programming environment. To evaluate the result of compression, several parameters were computed, including compression ratio, percentage root mean square difference, percentage root mean square residual energy, and space savings.…

  • Lingua: Inglese

    Editore: LAP LAMBERT Academic Publishing Apr 2026, 2026

    6209922325 / 9786209922329

    • Brossura
    • Print on Demand

    Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germaniabuchversandmimpf2000

    Venditore con 5 stelle
    Contatta il venditore

    Condizione: Nuovo

    EUR 93,90

    EUR 60,00 spedizione 
    Spedito da Germania a U.S.A.

    Quantità: 1 disponibile

    Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 212 pp. Englisch.