Tefko jozef (7 risultati)

- Brossura
Da: Kennys Bookshop and Art Galleries Ltd., Galway, IrlandaKennys Bookshop and Art Galleries Ltd.
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 78,22
EUR 10,50 spedizioneSpedito da Irlanda a U.S.A.Quantità: 15 disponibili
Condizione: New.

Model Fire in a Two-storey Timber Building
tefko, Jozef/ Osvald, Anton/ Osvaldová, Linda Makovická/ Sedlák, Pavol/ tefková, Jaroslava
- Brossura
Da: Revaluation Books, Exeter, Regno UnitoRevaluation Books
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 89,44
EUR 11,58 spedizioneSpedito da Regno Unito a U.S.A.Quantità: 2 disponibili
Paperback. Condizione: Brand New. 105 pages. 9.25x6.10x0.22 inches. In Stock.

- Brossura
Da: Kennys Bookstore, Olney, U.S.A.Kennys Bookstore
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 97,42
EUR 9,10 spedizioneSpedito in U.S.A.Quantità: 15 disponibili
Condizione: New.

- Brossura
Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 64,19
EUR 60,89 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibili
Taschenbuch. Condizione: Neu. Druck auf Anfrage Neuware - Printed after ordering - This book addresses the performance of a multi-storey timber building subjected to a model fire that represents a real, potentially devastating internal fire.Readers will learn about factors concerning fire hazards in buildings; the mechanisms of…how fires start and spread; and the degrading impact of fire on wood and wood-based materials, especially their mechanical properties. The book also discusses the fire resistance of timber buildings and the design principles for fire safety, summarised in Eurocodes.In turn, a fire test on a full-size wooden structure demonstrates the principles discussed. The test makes up an essential part of the book, as to its individual steps: the development, planning, execution and subsequent assessment. This is complemented by detailed temperature monitoring at hundreds of individual spots and the reaction of the wood constructions, illustrated in extensive photo documentation. The temperature and fire development presented there show the fire's initial mechanism and its further behaviour in a wood construction. The test proved the feasibility of fire protection and safe design of timber buildings, offering insights that can be generally applied in research, material and construction development. Accordingly, the book will be especially useful for architects, building and fire engineers, as well as researchers dealing with the fire performance of timber buildings.

- Brossura
Da: preigu, Osnabrück, Germaniapreigu
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 59,30
EUR 70,00 spedizioneSpedito da Germania a U.S.A.Quantità: 5 disponibili
Taschenbuch. Condizione: Neu. Model Fire in a Two-Storey Timber Building | Jozef ¿Tefko (u. a.) | Taschenbuch | SpringerBriefs in Fire | xxiii | Englisch | 2021 | Springer | EAN 9783030822040 | Verantwortliche Person für die EU: Springer Verlag GmbH, Tiergartenstr. 17, 69121 Heidelberg, juergen[dot]hartmann[at]springer[dot]com |… Anbieter: preigu.

- Brossura
- Print on Demand
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermaniaBuchWeltWeit Ludwig Meier e.K.
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 64,19
EUR 23,00 spedizioneSpedito da Germania a U.S.A.Quantità: 2 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This book addresses the performance of a multi-storey timber building subjected to a model fire that represents a real, potentially devastating internal fire.Readers will learn about factors concerning fire hazards in buildings; th…e mechanisms of how fires start and spread; and the degrading impact of fire on wood and wood-based materials, especially their mechanical properties. The book also discusses the fire resistance of timber buildings and the design principles for fire safety, summarised in Eurocodes.In turn, a fire test on a full-size wooden structure demonstrates the principles discussed. The test makes up an essential part of the book, as to its individual steps: the development, planning, execution and subsequent assessment. This is complemented by detailed temperature monitoring at hundreds of individual spots and the reaction of the wood constructions, illustrated in extensive photo documentation. The temperature and fire development presented there show the fire's initial mechanism and its further behaviour in a wood construction. The test proved the feasibility of fire protection and safe design of timber buildings, offering insights that can be generally applied in research, material and construction development. Accordingly, the book will be especially useful for architects, building and fire engineers, as well as researchers dealing with the fire performance of timber buildings. 108 pp. Englisch.

- Brossura
- Print on Demand
Da: buchversandmimpf2000, Emtmannsberg, Germaniabuchversandmimpf2000
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 64,19
EUR 60,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -This book addresses the performance of a multi-storey timber building subjected to a model fire that represents a real, potentially devastating internal fire. Readers will learn about factors concerning fire hazards in buildings; the m…echanisms of how fires start and spread; and the degrading impact of fire on wood and wood-based materials, especially their mechanical properties. The book also discusses the fire resistance of timber buildings and the design principles for fire safety, summarised in Eurocodes.In turn, a fire test on a full-size wooden structure demonstrates the principles discussed. The test makes up an essential part of the book, as to its individual steps: the development, planning, execution and subsequent assessment. This is complemented by detailed temperature monitoring at hundreds of individual spots and the reaction of the wood constructions, illustrated in extensive photo documentation.The temperature and fire development presented there show the fire's initial mechanism and its further behaviour in a wood construction. The test proved the feasibility of fire protection and safe design of timber buildings, offering insights that can be generally applied in research, material and construction development. Accordingly, the book will be especially useful for architects, building and fire engineers, as well as researchers dealing with the fire performance of timber buildings.Springer-Verlag KG, Sachsenplatz 4-6, 1201 Wien 108 pp. Englisch.