Ula¿ ba¿c¿ (4 risultati)

- Brossura
Da: preigu, Osnabrück, Germaniapreigu
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 58,25
EUR 70,00 spedizioneSpedito da Germania a U.S.A.Quantità: 5 disponibili
Taschenbuch. Condizione: Neu. Automatic Anatomy Recognition and Registration | Medical Image Processing and Analysis | Ula¿ Ba¿C¿ | Taschenbuch | 168 S. | Englisch | 2010 | LAP LAMBERT Academic Publishing | EAN 9783838380148 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.…

- Brossura
- Print on Demand
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermaniaBuchWeltWeit Ludwig Meier e.K.
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 68,00
EUR 23,00 spedizioneSpedito da Germania a U.S.A.Quantità: 2 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This thesis tackles two major challenges in medical image analysis: image segmentation and registration. Specifically, we present a novel anatomy recognition algorithm for assisting the image segmentation task, and a novel image registration framework for accurately aligning images. Whilst the anatomy recognition study considers different clinical applications using MR (magnetic resonance) and CT (computed tomography) images, the image registration study uses MR and histological images. We have also developed a novel and effective method for registering histological images of a mouse brain in order to reconstruct the 3D volume. Experiments show that the choice of the reference slice has a significant impact on the quality of 3D reconstruction. Finally, since image intensity variations are inherent in MR images, and since the lack of a standard image intensity scale in MRI leads to many difficulties in tissue characterisability, image display, and analysis, including image segmentation and registration, we systematically investigated and evaluated the influence of intensity standardisation in automatic anatomy recognition and registration tasks using clinical MR images. 168 pp. Englisch.…

- Brossura
- Print on Demand
Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 75,50
EUR 35,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibile
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This thesis tackles two major challenges in medical image analysis: image segmentation and registration. Specifically, we present a novel anatomy recognition algorithm for assisting the image segmentation task, and a novel image registration framework for accurately aligning images. Whilst the anatomy recognition study considers different clinical applications using MR (magnetic resonance) and CT (computed tomography) images, the image registration study uses MR and histological images. We have also developed a novel and effective method for registering histological images of a mouse brain in order to reconstruct the 3D volume. Experiments show that the choice of the reference slice has a significant impact on the quality of 3D reconstruction. Finally, since image intensity variations are inherent in MR images, and since the lack of a standard image intensity scale in MRI leads to many difficulties in tissue characterisability, image display, and analysis, including image segmentation and registration, we systematically investigated and evaluated the influence of intensity standardisation in automatic anatomy recognition and registration tasks using clinical MR images.…

- Brossura
- Print on Demand
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germaniabuchversandmimpf2000
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 68,00
EUR 60,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibile
Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -This thesis tackles two major challenges in medical image analysis: image segmentation and registration. Specifically, we present a novel anatomy recognition algorithm for assisting the image segmentation task, and a novel image registration framework for accurately aligning images. Whilst the anatomy recognition study considers different clinical applications using MR (magnetic resonance) and CT (computed tomography) images, the image registration study uses MR and histological images. We have also developed a novel and effective method for registering histological images of a mouse brain in order to reconstruct the 3D volume. Experiments show that the choice of the reference slice has a significant impact on the quality of 3D reconstruction. Finally, since image intensity variations are inherent in MR images, and since the lack of a standard image intensity scale in MRI leads to many difficulties in tissue characterisability, image display, and analysis, including image segmentation and registration, we systematically investigated and evaluated the influence of intensity standardisation in automatic anatomy recognition and registration tasks using clinical MR images.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 168 pp. Englisch.…